Reconstruction of the shape of conductivity spectra using differential multi-frequency magnetic induction tomography

被引:32
|
作者
Brunner, Patricia [1 ]
Merwa, Robert
Missner, Andreas
Rosell, Javier
Hollaus, Karl
Scharfetter, Hermann
机构
[1] Graz Univ Technol, Inst Med Engn, Graz, Austria
[2] Univ Politecn Cataluna, Dept Elect Engn, Barcelona, Spain
[3] Graz Univ Technol, Inst Fundamentals & Theory Elect Engn, Graz, Austria
关键词
magnetic induction tomography (MIT); frequency-differential; conductivity spectrum;
D O I
10.1088/0967-3334/27/5/S20
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Magnetic induction tomography (MIT) of biological tissue is used for the reconstruction of the complex conductivity distribution K inside the object under investigation. It is based on the perturbation of an alternating magnetic field caused by the object and can be used in all applications of electrical impedance tomography (EIT) such as functional lung monitoring and assessment of tissue fluids. In contrast to EIT, MIT does not require electrodes and magnetic fields can also penetrate non-conducting barriers such as the skull. As in EIT, the reconstruction of absolute conductivity values is very difficult because of the method's sensitivity to numerical errors and noise. To overcome this problem, image reconstruction in EIT is often done differentially. Analogously, this concept has been adopted for MIT. Two different methods for differential imaging are applicable. The first one is state-differential, for example when the conductivity change between inspiration and expiration in the lung regions is being detected. The second one is frequency-differential, which is of high interest in motionless organs like the brain, where a state-differential method cannot be applied. An equation for frequency-differential MIT was derived taking into consideration the frequency dependence of the sensitivity matrix. This formula is valid if we can assume that only small conductivity changes occur. In this way, the non-linear inverse problem of MIT can be approximated by a linear one (depending only on the frequency), similar to in EIT. Keeping this limitation in mind, the conductivity changes between one or more reference frequencies and several measurement frequencies were reconstructed, yielding normalized conductivity spectra. Due to the differential character of the method, these spectra do not provide absolute conductivities but preserve the shape of the spectrum. The validity of the method was tested with artificial data generated with a spherical perturbation within a conducting cylinder as well as for real measurement data. The measurement data were obtained from a potato immersed in saline. The resulting spectra were compared with reference measurements and the preservation of the shape of the spectra was analyzed.
引用
收藏
页码:S237 / S248
页数:12
相关论文
共 50 条
  • [31] Conductivity Prediction and Image Reconstruction of Complex-Valued Multi-Frequency Electrical Capacitance Tomography Based on Deep Neural Network
    Zhu, Liying
    Jiang, Yandan
    Li, Yi
    Lu, Wu
    Zhang, Maomao
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [32] Research of the conductivity of organic and inorganic media in multi-angle multi-frequency electrical impedance tomography
    Aleksanyan, Grayr
    Shcherbakov, Ivan
    Kucher, Artem
    Priyma, Maria
    XIII INTERNATIONAL SCIENTIFIC-TECHNICAL CONFERENCE DYNAMIC OF TECHNICAL SYSTEMS (DTS-2017), 2017, 132
  • [33] Absolute Imaging of Low Conductivity Material Distributions Using Nonlinear Reconstruction Methods in Magnetic Induction Tomography
    Dekdouk, Bachir
    Ktistis, Christos
    Armitage, David W.
    Peyton, Anthony J.
    PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2016, 155 : 1 - 18
  • [34] Robust Reconstruction of Elasticity Using Ultrasound Imaging and Multi-Frequency Excitations
    Otesteanu, Corin F.
    Sanabria, Sergio J.
    Goksel, Orcun
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (11) : 2502 - 2513
  • [35] Multi-frequency acousto-electromagnetic tomography
    Alberti, Giovanni S.
    Ammari, Habib
    Ruan, Kaixi
    PANORAMA OF MATHEMATICS: PURE AND APPLIED, 2016, 658 : 67 - +
  • [36] Anisotropic conductivity tensor imaging using magnetic induction tomography
    Guersoy, D.
    Scharfetter, H.
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (08) : S135 - S145
  • [37] A multi-frequency catalog of magnetic CVs
    Mason, Paul A.
    Monroy, Lorena C.
    Wells, Natalie K.
    Santana, Joshua B.
    Proceedings of Science, 2019, 362
  • [38] Inversion of multi-frequency electromagnetic induction data for 3D characterization of hydraulic conductivity
    Brosten, Troy R.
    Day-Lewis, Frederick D.
    Schultz, Gregory M.
    Curtis, Gary P.
    Lane, John W., Jr.
    JOURNAL OF APPLIED GEOPHYSICS, 2011, 73 (04) : 323 - 335
  • [39] Study on Multi-frequency Characteristics of Lung Cancer Conductivity
    Li, Jia
    Yue, Shihong
    Ding, Mingliang
    Wang, Huaxiang
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 215 - 220
  • [40] Reconstruction of admittivity distribution without phase measurements in multi-frequency electrical impedance tomography (MFEIT)
    Kuusela, P.
    Pourghaz, M.
    Seppanen, A.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2025, 36 (03)