Reconstruction of the shape of conductivity spectra using differential multi-frequency magnetic induction tomography

被引:32
|
作者
Brunner, Patricia [1 ]
Merwa, Robert
Missner, Andreas
Rosell, Javier
Hollaus, Karl
Scharfetter, Hermann
机构
[1] Graz Univ Technol, Inst Med Engn, Graz, Austria
[2] Univ Politecn Cataluna, Dept Elect Engn, Barcelona, Spain
[3] Graz Univ Technol, Inst Fundamentals & Theory Elect Engn, Graz, Austria
关键词
magnetic induction tomography (MIT); frequency-differential; conductivity spectrum;
D O I
10.1088/0967-3334/27/5/S20
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Magnetic induction tomography (MIT) of biological tissue is used for the reconstruction of the complex conductivity distribution K inside the object under investigation. It is based on the perturbation of an alternating magnetic field caused by the object and can be used in all applications of electrical impedance tomography (EIT) such as functional lung monitoring and assessment of tissue fluids. In contrast to EIT, MIT does not require electrodes and magnetic fields can also penetrate non-conducting barriers such as the skull. As in EIT, the reconstruction of absolute conductivity values is very difficult because of the method's sensitivity to numerical errors and noise. To overcome this problem, image reconstruction in EIT is often done differentially. Analogously, this concept has been adopted for MIT. Two different methods for differential imaging are applicable. The first one is state-differential, for example when the conductivity change between inspiration and expiration in the lung regions is being detected. The second one is frequency-differential, which is of high interest in motionless organs like the brain, where a state-differential method cannot be applied. An equation for frequency-differential MIT was derived taking into consideration the frequency dependence of the sensitivity matrix. This formula is valid if we can assume that only small conductivity changes occur. In this way, the non-linear inverse problem of MIT can be approximated by a linear one (depending only on the frequency), similar to in EIT. Keeping this limitation in mind, the conductivity changes between one or more reference frequencies and several measurement frequencies were reconstructed, yielding normalized conductivity spectra. Due to the differential character of the method, these spectra do not provide absolute conductivities but preserve the shape of the spectrum. The validity of the method was tested with artificial data generated with a spherical perturbation within a conducting cylinder as well as for real measurement data. The measurement data were obtained from a potato immersed in saline. The resulting spectra were compared with reference measurements and the preservation of the shape of the spectra was analyzed.
引用
收藏
页码:S237 / S248
页数:12
相关论文
共 50 条
  • [21] 3D Shape Reconstruction Using a Novel Multi-Frequency Linear Sampling Method Predictor
    Alqadah, H. F.
    Valdivia, N.
    2014 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), 2014, : 151 - 154
  • [22] Magneto-Acousto-Electrical Tomography With Magnetic Induction for Conductivity Reconstruction
    Guo, Liang
    Liu, Guoqiang
    Xia, Hui
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (09) : 2114 - 2124
  • [23] Shape object recovering using multi-frequency fringe projection
    Cuevas, FJ
    Servin, M
    RodriguezVera, R
    Marroquin, JL
    SECOND IBEROAMERICAN MEETING ON OPTICS, 1996, 2730 : 354 - 358
  • [24] Multi-frequency diffuse optical tomography
    Intes, X
    Chance, B
    JOURNAL OF MODERN OPTICS, 2005, 52 (15) : 2139 - 2159
  • [25] Regional Admittivity Reconstruction With Multi-Frequency Complex Admittance Data Using Contactless Capacitive Electrical Tomography
    Ma, Gege
    Soleimani, Manuchehr
    IEEE SENSORS JOURNAL, 2021, 21 (13) : 15277 - 15290
  • [26] Reconstruction of Conductivity Distribution in Low Conductive Materials Using Magnetic Induction Tomography and Adjoint Model
    Baniukiewicz, Piotr
    COMPUTER FIELD MODELS OF ELECTROMAGNETIC DEVICES, 2010, 34 : 897 - 903
  • [27] Tissue characterization using a multi-frequency of electrical impedance tomography
    Shallof, A.M.
    Barber, D.C.
    IEE Colloquium (Digest), 1996, (143):
  • [28] Depth Sensitivity of Apparent Magnetic Susceptibility Measurements using Multi-coil and Multi-frequency Electromagnetic Induction
    Sadatcharam, Kamaleswaran
    Altdorff, Daniel
    Unc, Adrian
    Krishnapillai, Manokarajah
    Galagedara, Lakshman
    JOURNAL OF ENVIRONMENTAL AND ENGINEERING GEOPHYSICS, 2020, 25 (03) : 301 - 314
  • [29] Shape reconstruction of the multi-scale rough surface from multi-frequency phaseless data
    Bao, Gang
    Zhang, Lei
    INVERSE PROBLEMS, 2016, 32 (08)
  • [30] Correction of systematic errors in frequency differential magnetic induction tomography
    Scharfetter, H.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 476 - 479