Reconstruction of the shape of conductivity spectra using differential multi-frequency magnetic induction tomography

被引:32
|
作者
Brunner, Patricia [1 ]
Merwa, Robert
Missner, Andreas
Rosell, Javier
Hollaus, Karl
Scharfetter, Hermann
机构
[1] Graz Univ Technol, Inst Med Engn, Graz, Austria
[2] Univ Politecn Cataluna, Dept Elect Engn, Barcelona, Spain
[3] Graz Univ Technol, Inst Fundamentals & Theory Elect Engn, Graz, Austria
关键词
magnetic induction tomography (MIT); frequency-differential; conductivity spectrum;
D O I
10.1088/0967-3334/27/5/S20
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Magnetic induction tomography (MIT) of biological tissue is used for the reconstruction of the complex conductivity distribution K inside the object under investigation. It is based on the perturbation of an alternating magnetic field caused by the object and can be used in all applications of electrical impedance tomography (EIT) such as functional lung monitoring and assessment of tissue fluids. In contrast to EIT, MIT does not require electrodes and magnetic fields can also penetrate non-conducting barriers such as the skull. As in EIT, the reconstruction of absolute conductivity values is very difficult because of the method's sensitivity to numerical errors and noise. To overcome this problem, image reconstruction in EIT is often done differentially. Analogously, this concept has been adopted for MIT. Two different methods for differential imaging are applicable. The first one is state-differential, for example when the conductivity change between inspiration and expiration in the lung regions is being detected. The second one is frequency-differential, which is of high interest in motionless organs like the brain, where a state-differential method cannot be applied. An equation for frequency-differential MIT was derived taking into consideration the frequency dependence of the sensitivity matrix. This formula is valid if we can assume that only small conductivity changes occur. In this way, the non-linear inverse problem of MIT can be approximated by a linear one (depending only on the frequency), similar to in EIT. Keeping this limitation in mind, the conductivity changes between one or more reference frequencies and several measurement frequencies were reconstructed, yielding normalized conductivity spectra. Due to the differential character of the method, these spectra do not provide absolute conductivities but preserve the shape of the spectrum. The validity of the method was tested with artificial data generated with a spherical perturbation within a conducting cylinder as well as for real measurement data. The measurement data were obtained from a potato immersed in saline. The resulting spectra were compared with reference measurements and the preservation of the shape of the spectra was analyzed.
引用
收藏
页码:S237 / S248
页数:12
相关论文
共 50 条
  • [1] Feasibility of Head Imaging Using Multi-frequency Magnetic Induction Tomography
    Gursoy, Doga
    Scharfetter, Hermann
    BIYOMUT: 2009 14TH NATIONAL BIOMEDICAL ENGINEERING MEETING, 2009, : 502 - 504
  • [2] Simultaneous reconstruction of permittivity and conductivity using multi-frequency admittance measurement in electrical capacitance tomography
    Zhang, Maomao
    Soleimani, Manuchehr
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (02)
  • [3] Magnetic induction tomography: hardware for multi-frequency measurements in biological tissues
    Scharfetter, H
    Lackner, HK
    Rosell, J
    PHYSIOLOGICAL MEASUREMENT, 2001, 22 (01) : 131 - 146
  • [4] Multi-frequency difference method for intracranial hemorrhage detection by magnetic induction tomography
    Xiao, Zhili
    Tan, Chao
    Dong, Feng
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (05)
  • [5] Multi-frequency Magnetic Induction Tomography based on Identification Method and SAE Network
    Chen, Ruijuan
    Zhang, Yuanxin
    Zhao, Songsong
    Zhu, Xinlei
    Wang, Huiquan
    Wang, Jinhai
    JOURNAL OF IMAGING SCIENCE AND TECHNOLOGY, 2024, 68 (04) : 17 - 17
  • [6] Multi-Frequency Magnetic Induction Tomography System and Algorithm for Imaging Metallic Objects
    Dingley, Gavin
    Soleimani, Manuchehr
    SENSORS, 2021, 21 (11)
  • [7] Absolute conductivity reconstruction in magnetic induction tomography using a nonlinear method
    Soleimani, Manuchehr
    Lionheart, William R. B.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (12) : 1521 - 1530
  • [8] Interior Void Classification in Liquid Metal Using Multi-Frequency Magnetic Induction Tomography With a Machine Learning Approach
    Muttakin, Imamul
    Soleimani, Manuchehr
    IEEE SENSORS JOURNAL, 2021, 21 (20) : 23289 - 23296
  • [9] The Multi-Frequency Responses and Sensitivity Calculation of Broadband Magnetic Induction Tomography System Using the Boundary Element Method
    Zhao, Qian
    Yin, Wuliang
    2014 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS & TECHNIQUES (IST), 2014, : 48 - 52
  • [10] Improvement on Conductivity Image Reconstruction in Magnetic Induction Tomography
    Yazdanian, Hassan
    Jafari, Reza
    2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 864 - 868