High-Field/High-Frequency EPR spectrometer operating in pulsed and continuous-wave mode at 180 GHz

被引:42
|
作者
Rohrer, M [1 ]
Brügmann, O [1 ]
Kinzer, B [1 ]
Prisner, TF [1 ]
机构
[1] Goethe Univ Frankfurt, Inst Phys & Theoret Chem, D-60439 Frankfurt, Germany
关键词
D O I
10.1007/BF03162406
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A novel electron paramagnetic resonance (EPR) spectrometer is reported, which has been developed to allow pulsed EPR experiments with high sensitivity and time resolution at a microwave (MW) frequency of 180 GHz (G-band) and wavelengths of approximately 1.6 mm. This corresponds to a magnetic field of about 6.4 T for g approximate to 2 signals. The "hybrid" system architecture combines components of quasioptical as well as conventional MW techniques, making it possible to achieve excellent spectrometer performance with respect to sensitivity and time resolution, Quasioptical MW components have been used to design an MW circulator allowing high sensitivity and low bias operation in the reflection mode. A miniaturized, closed-type cylindrical cavity provides a high sample filling factor and an adequate MW field strength (B-1) enhancement and thus permits reasonably short MW pulses (60 ns for a pi/2 pulse) even with a moderate MW input power (15 mW at the cavity). Commercial quartz capillaries (up to 0.5 mm internal diameter) can be used as sample holders for a broad range of applications.
引用
收藏
页码:257 / 274
页数:18
相关论文
共 50 条
  • [1] High-field/high-frequency EPR spectrometer operating in pulsed and continuous-wave mode at 180 GHz
    M. Rohrer
    O. Brügmann
    B. Kinzer
    T. F. Prisner
    [J]. Applied Magnetic Resonance, 2001, 21 : 257 - 274
  • [2] A NOVEL HIGH-FIELD HIGH-FREQUENCY EPR AND ENDOR SPECTROMETER OPERATING AT 3 MM WAVELENGTH
    BURGHAUS, O
    ROHRER, M
    GOTZINGER, T
    PLATO, M
    MOBIUS, K
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1992, 3 (08) : 765 - 774
  • [3] A high-field/high-frequency heterodyne induction-mode electron paramagnetic resonance spectrometer operating at 360 GHz
    Fuchs, MR
    Prisner, TF
    Mobius, K
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (09): : 3681 - 3683
  • [4] High-field and high-frequency EPR
    G. R. Eaton
    S. S. Eaton
    [J]. Applied Magnetic Resonance, 1999, 16 : 161 - 166
  • [5] High-field and high-frequency EPR
    Eaton, GR
    Eaton, SS
    [J]. APPLIED MAGNETIC RESONANCE, 1999, 16 (02) : 161 - 166
  • [6] PULSED 95-GHZ, HIGH-FIELD EPR HETERODYNE SPECTROMETER WITH HIGH SPECTRAL AND TIME RESOLUTION
    PRISNER, TF
    ROHRER, M
    MOBIUS, K
    [J]. APPLIED MAGNETIC RESONANCE, 1994, 7 (2-3) : 167 - 183
  • [7] A continuous-wave and pulsed electron spin resonance spectrometer operating at 275 GHz
    Blok, H
    Disselhorst, JAJM
    Orlinskii, SB
    Schmidt, J
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2004, 166 (01) : 92 - 99
  • [8] High-frequency/high-field EPR spectroscopy of metalloproteins and models
    Hagen, WR
    [J]. JOURNAL OF INORGANIC BIOCHEMISTRY, 1999, 74 (1-4) : 28 - 28
  • [9] Pulsed-high Field/High-frequency EPR spectroscopy
    Fuhs, M
    Möbius, K
    [J]. HIGH MAGNETIC FIELDS: APPLICATIONS IN CONDENSED MATTER PHYSICS AND SPECTROSCOPY, 2001, 595 : 476 - 493
  • [10] High-frequency high-power DNP/EPR spectrometer operating at 7 T magnetic field
    Nevzorov, Alexander A.
    Marek, Antonin
    Milikisiyants, Sergey
    Smirnov, Alex I.
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2024, 362