High-frequency high-power DNP/EPR spectrometer operating at 7 T magnetic field

被引:1
|
作者
Nevzorov, Alexander A. [1 ]
Marek, Antonin [1 ]
Milikisiyants, Sergey [1 ]
Smirnov, Alex I. [1 ]
机构
[1] North Carolina State Univ, Dept Chem, 2620 Yarbrough Dr, Raleigh, NC 27695 USA
关键词
Dynamic nuclear polarization; Electron spin echoes; Extended interaction klystron; Quasioptics; Solid-state mm-wave devices; DYNAMIC NUCLEAR-POLARIZATION; ELECTRON-SPIN-RESONANCE; NMR; DNP; EPR; MHZ;
D O I
10.1016/j.jmr.2024.107677
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
One of the most essential prerequisites for the development of pulse Dynamic Nuclear Polarization (DNP) is the ability to generate high-power coherent mm-wave pulses at the electron precession frequencies corresponding to the magnetic fields of modern high-resolution NMR spectrometers. As a major step towards achieving this goal, an Extended Interaction Klystron (EIK) pulse amplifier custom-built by the Communications and Power Industries, Inc. and producing up to 140 W at 197.8 GHz, was integrated with in-house built NMR/DNP/EPR spectrometer operating at 7 T magnetic field. The spectrometer employs a Thomas Keating, Ltd. quasioptical bridge to direct mm-waves into a homebuilt DNP probe incorporating photonic bandgap (PBG) resonators to further boost electronic B 1e fields. Three-pulse electron spin echo nutation experiments were employed to characterize the B 1e fields at the sample by operating the homodyne 198 GHz bridge in an induction mode. Room-temperature experiments with a single-crystal high-pressure, high-temperature (HPHT) diamond and a polystyrene film doped with BDPA radical yielded < 9 ns pi/2 pulses at ca . 50 W specified EIK output at the corresponding resonance frequencies and the PBG resonator quality factor of Q approximate to 300. DNP experiments carried out in a "gated" mode by supplying 20 mu s mm-wave pulses every 1 ms yielded C-13 solid-effect DNP with gains up to 20 for the polystyrene-BDPA sample at natural C-13 abundance. For a single-crystal HPHT diamond, the gated DNP mode yielded almost the same C-13 enhancement as a low-power continuous wave (CW) mode at 0.4 W, whereas no DNP effect was observed for the BDPA/polystyrene sample in the latter case. To illustrate the versatility of our upgraded DNP spectrometer, room-temperature Overhauser DNP enhancements of 7-14 for P-31 NMR signal were demonstrated using a liquid droplet of 1 M tri-phenyl phosphine co-dissolved with 100 mM of BDPA in toluene-d(g).
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A NOVEL HIGH-FIELD HIGH-FREQUENCY EPR AND ENDOR SPECTROMETER OPERATING AT 3 MM WAVELENGTH
    BURGHAUS, O
    ROHRER, M
    GOTZINGER, T
    PLATO, M
    MOBIUS, K
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1992, 3 (08) : 765 - 774
  • [2] The CW-EPR Capabilities of a Dual DNP/EPR Spectrometer Operating at 14 and 7 T
    Nir-Arad, Orit
    Shlomi, David H.
    Israelstam, Amit
    Amit, Tomer
    Manukovsky, Nurit
    Fialkov, Alexander B.
    Kaminker, Ilia
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2024, 360
  • [3] High-Field/High-Frequency EPR spectrometer operating in pulsed and continuous-wave mode at 180 GHz
    Rohrer, M
    Brügmann, O
    Kinzer, B
    Prisner, TF
    [J]. APPLIED MAGNETIC RESONANCE, 2001, 21 (3-4) : 257 - 274
  • [4] High-field/high-frequency EPR spectrometer operating in pulsed and continuous-wave mode at 180 GHz
    M. Rohrer
    O. Brügmann
    B. Kinzer
    T. F. Prisner
    [J]. Applied Magnetic Resonance, 2001, 21 : 257 - 274
  • [5] HIGH-POWER THYRISTOR MAGNETIC HIGH-FREQUENCY HARMONIC GENERATOR
    DUBINKER, AS
    [J]. TELECOMMUNICATIONS AND RADIO ENGINEERING, 1980, 34-5 (11) : 118 - 121
  • [6] High-field and high-frequency EPR
    G. R. Eaton
    S. S. Eaton
    [J]. Applied Magnetic Resonance, 1999, 16 : 161 - 166
  • [7] HIGH-POWER HIGH-FREQUENCY SWITCHING
    VORONOV, VI
    KIRILOV, AE
    SOLDATOV, AN
    FEDOROV, VF
    YUDIN, NA
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1982, 25 (01) : 171 - 172
  • [8] High-field and high-frequency EPR
    Eaton, GR
    Eaton, SS
    [J]. APPLIED MAGNETIC RESONANCE, 1999, 16 (02) : 161 - 166
  • [9] Soft Magnetic Materials in High-Frequency, High-Power Conversion Applications
    Alex M. Leary
    Paul R. Ohodnicki
    Michael E. McHenry
    [J]. JOM, 2012, 64 : 772 - 781
  • [10] Soft Magnetic Materials in High-Frequency, High-Power Conversion Applications
    Leary, Alex M.
    Ohodnicki, Paul R.
    McHenry, Michael E.
    [J]. JOM, 2012, 64 (07) : 772 - 781