A high-field/high-frequency heterodyne induction-mode electron paramagnetic resonance spectrometer operating at 360 GHz

被引:67
|
作者
Fuchs, MR
Prisner, TF
Mobius, K
机构
[1] Free Univ Berlin, D-14195 Berlin, Germany
[2] Univ Frankfurt, D-60439 Frankfurt, Germany
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1999年 / 70卷 / 09期
关键词
D O I
10.1063/1.1149977
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present design details of and first measurements with a novel continuous wave (cw) high-field/high-frequency electron paramagnetic resonance spectrometer operating at a microwave frequency of 360 GHz and a magnetic field of up to 14 T. The spectrometer design incorporates a heterodyne mixer detection scheme with a quasi-optical transmission line and a bimodal induction mode Fabry-Perot cavity. First cw experiments on polycrystalline 1,1-diphenyl-2-picryl-hydrazyl and bisdiphenylene-beta-phenylallyl benzolate in polystyrene at room temperature and 4-hydroxy-2,2,6,6-tetramethylpiperidine-1-oxyl in frozen solution at 190 K demonstrate the high Zeeman resolution achievable and allow an estimate of the present detection sensitivity of 4x10(9) spins/G at a detection bandwidth of 1 Hz. (C) 1999 American Institute of Physics. [S0034-6748(99)03709-0].
引用
收藏
页码:3681 / 3683
页数:3
相关论文
共 50 条
  • [1] High-field and high-frequency electron paramagnetic resonance
    Möbius, K
    [J]. APPLIED MAGNETIC RESONANCE, 2001, 21 (3-4) : 255 - 255
  • [2] High-field and high-frequency electron paramagnetic resonance
    Klaus Möbius
    [J]. Applied Magnetic Resonance, 2001, 21 : 255 - 255
  • [3] High-field and high-frequency electron paramagnetic resonance instrumentation
    Sandra S. Eaton
    Gareth R. Eaton
    [J]. Applied Magnetic Resonance, 1999, 16 : 159 - 160
  • [4] High-field and high-frequency electron paramagnetic resonance instrumentation
    Eaton, SS
    Eaton, GR
    [J]. APPLIED MAGNETIC RESONANCE, 1999, 16 (02) : 159 - 160
  • [5] High-Field/High-Frequency EPR spectrometer operating in pulsed and continuous-wave mode at 180 GHz
    Rohrer, M
    Brügmann, O
    Kinzer, B
    Prisner, TF
    [J]. APPLIED MAGNETIC RESONANCE, 2001, 21 (3-4) : 257 - 274
  • [6] High-field/high-frequency EPR spectrometer operating in pulsed and continuous-wave mode at 180 GHz
    M. Rohrer
    O. Brügmann
    B. Kinzer
    T. F. Prisner
    [J]. Applied Magnetic Resonance, 2001, 21 : 257 - 274
  • [7] A novel probe head for high-field, high-frequency electron paramagnetic resonance
    Annino, G
    Cassettari, M
    Longo, I
    Martinelli, M
    Van Bentum, PJM
    Van der Horst, E
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (03): : 1787 - 1793
  • [8] MEPROS - Modular electron paramagnetic resonance operating software for multifunctional high-frequency EPR spectrometer
    Sedivy, Mattus
    Santana, Vinicius
    Sojka, Antonin
    Laguta, Oleksii
    Neugebauer, Petr
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2023, 355
  • [9] Tunable-frequency high-field electron paramagnetic resonance
    Krzystek, J
    Zvyagin, SA
    Ozarowski, A
    Trofimenko, S
    Telser, J
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2006, 178 (02) : 174 - 183
  • [10] High-frequency and high-field electron paramagnetic resonance (HFEPR): a new spectroscopic tool for bioinorganic chemistry
    Joshua Telser
    J. Krzystek
    Andrew Ozarowski
    [J]. JBIC Journal of Biological Inorganic Chemistry, 2014, 19 : 297 - 318