Contrast-Enhanced Ultrasound Combined with Three-Dimensional Reconstruction in Preoperative Perforator Flap Planning

被引:44
|
作者
Su, Weijie
Lu, Linguo
Lazzeri, Davide
Zhang, Yi Xin [1 ]
Wang, Danru
Innocenti, Marco
Qian, Yunliang
Agostini, Tommaso
Levin, L. Scott
Messmer, Caroline
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, Dept Plast & Reconstruct Surg, Shanghai 200030, Peoples R China
关键词
ROW COMPUTED-TOMOGRAPHY; BREAST RECONSTRUCTION; ARTERY PERFORATOR; RECIPIENT VESSELS; SKIN-FLAPS; SUPERMICROSURGERY; ANGIOGRAPHY; ANATOMY;
D O I
10.1097/PRS.0b013e3182729e9e
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Along with technical advancements in perforator flap surgery, great interest has been recently focused on the accuracy of preoperative perforator location through the assessment of the donor-site vascular network. The goal of the present study was to investigate the usefulness of contrast-enhanced ultrasound combined with three-dimensional reconstruction in the planning of perforator flaps. Methods: The authors retrospectively analyzed the preoperative imaging vascular anatomy provided by contrast-enhanced ultrasound combined with three-dimensional reconstruction in 32 patients undergoing perforator flap reconstruction between 2009 and 2011. The static and dynamic features of any suitable perforator including number of branches, source vessel, running course, blood flow pattern and velocity (peak systolic velocity and resistance index), and its anatomical relationship were assessed preoperatively by the novel navigation imaging. Based on this information, the preferred perforator and the ideal donor site were selected for the flap harvesting. The accuracy of preoperative imaging data was checked during surgery. Result: Contrast-enhanced ultrasound provided a continuous blood flow signal and a clear and reliable image of perforators, and three-dimensional reconstruction displayed their spatial anatomical relationship and their roots. Consistent with the surgical findings, perforators were identified accurately in all 32 cases with high specificity (100 percent) and sensitivity. Conclusions: Contrast-enhanced ultrasound with three-dimensional image re-construction provides valuable preoperative perforator navigation. It detects precisely the perforator's location, its course, and the quality of its blood flow and allows the choice of the preferred perforator and the ideal donor site. Preoperative location of perforators using contrast-enhanced ultrasound with three-dimensional image reconstruction improves flap planning and eases flap harvesting. (Plast. Reconstr. Surg. 131: 80, 2013.)
引用
收藏
页码:80 / 93
页数:14
相关论文
共 50 条
  • [31] RETRACTED: Diagnosis of Chronic Kidney Disease by Three-Dimensional Contrast-Enhanced Ultrasound Combined with Augmented Reality Medical Technology (Retracted Article)
    Zhuang, Yan
    Sun, Juanjuan
    Liu, Jiaqiang
    JOURNAL OF HEALTHCARE ENGINEERING, 2021, 2021
  • [32] Three-dimensional contrast-enhanced ultrasound improves endoleak detection and classification after endovascular aneurysm repair
    Lowe, Christopher
    Abbas, Abeera
    Rogers, Steven
    Smith, Lee
    Ghosh, Jonathan
    McCollum, Charles
    JOURNAL OF VASCULAR SURGERY, 2017, 65 (05) : 1453 - 1459
  • [33] The evolution of facial artery perforator flap for midface reconstruction with preoperative ultrasound examination
    Paloma Malagón
    Jesús González
    European Journal of Plastic Surgery, 2022, 45 : 933 - 939
  • [34] Treatment response evaluation with three-dimensional contrast-enhanced ultrasound for liver cancer after local therapies
    Xu, Hui-Xiong
    Lu, Ming-De
    Xie, Xiao-Hua
    Xie, Xiao-Yan
    Kuang, Ming
    Xu, Zuo-Feng
    Liu, Guang-Jian
    Wang, Zhu
    Chen, Li-Da
    Lin, Man-Xia
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (01) : 81 - 88
  • [35] Contrast-enhanced ultrasound and color doppler ultrasound as guidance for transhepatic artery chemoembolization following three-dimensional conformal radiotherapy
    Zhang, G.
    Jiang, Y.
    Zhou, S.
    He, L.
    Chen, M.
    Long, Z.
    Xing, H.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (01): : 55 - 59
  • [36] Immediate evaluation and guidance of liver cancer thermal ablation by three-dimensional ultrasound/contrast-enhanced ultrasound fusion imaging
    Xu, Er-Jiao
    Lv, Shu-Min
    Li, Kai
    Long, Ying-Lin
    Zeng, Qing-Jing
    Su, Zhong-Zhen
    Zheng, Rong-Qin
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2018, 34 (06) : 870 - 876
  • [37] Clinical utility of contrast-enhanced three-dimensional ultrasound imaging with Sonazoid: Findings on hepatocellular carcinoma lesions
    Luo, Wen
    Numata, Kazushi
    Morimoto, Manabu
    Nozaki, Akito
    Nagano, Yasuhiko
    Sugimori, Kazuya
    Zhou, Xiaodong
    Tanaka, Katsuaki
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (03) : 425 - 431
  • [38] Accuracy and utility of three-dimensional contrast-enhanced magnetic resonance angiography in planning carotid stenting - Discussion
    Jordan, William
    Timaran, Carlos
    JOURNAL OF VASCULAR SURGERY, 2007, 46 (02) : 263 - 264
  • [39] Application of Combined Two-Dimensional and Three-Dimensional Transvaginal Contrast Enhanced Ultrasound in the Diagnosis of Endometrial Carcinoma
    Zhou, Hui-li
    Xiang, Hong
    Duan, Li
    Shahai, Gulinaer
    Liu, Hui
    Li, Xiang-hong
    Mou, Rui-xue
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [40] Three-dimensional reconstruction of the pelvis for preoperative planning and simulation in orthopedic surgery
    Kurth, A
    Wassum, P
    Dietz, U
    Scale, D
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1997, 135 (02): : 120 - 123