Contrast-Enhanced Ultrasound Combined with Three-Dimensional Reconstruction in Preoperative Perforator Flap Planning

被引:44
|
作者
Su, Weijie
Lu, Linguo
Lazzeri, Davide
Zhang, Yi Xin [1 ]
Wang, Danru
Innocenti, Marco
Qian, Yunliang
Agostini, Tommaso
Levin, L. Scott
Messmer, Caroline
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, Dept Plast & Reconstruct Surg, Shanghai 200030, Peoples R China
关键词
ROW COMPUTED-TOMOGRAPHY; BREAST RECONSTRUCTION; ARTERY PERFORATOR; RECIPIENT VESSELS; SKIN-FLAPS; SUPERMICROSURGERY; ANGIOGRAPHY; ANATOMY;
D O I
10.1097/PRS.0b013e3182729e9e
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Along with technical advancements in perforator flap surgery, great interest has been recently focused on the accuracy of preoperative perforator location through the assessment of the donor-site vascular network. The goal of the present study was to investigate the usefulness of contrast-enhanced ultrasound combined with three-dimensional reconstruction in the planning of perforator flaps. Methods: The authors retrospectively analyzed the preoperative imaging vascular anatomy provided by contrast-enhanced ultrasound combined with three-dimensional reconstruction in 32 patients undergoing perforator flap reconstruction between 2009 and 2011. The static and dynamic features of any suitable perforator including number of branches, source vessel, running course, blood flow pattern and velocity (peak systolic velocity and resistance index), and its anatomical relationship were assessed preoperatively by the novel navigation imaging. Based on this information, the preferred perforator and the ideal donor site were selected for the flap harvesting. The accuracy of preoperative imaging data was checked during surgery. Result: Contrast-enhanced ultrasound provided a continuous blood flow signal and a clear and reliable image of perforators, and three-dimensional reconstruction displayed their spatial anatomical relationship and their roots. Consistent with the surgical findings, perforators were identified accurately in all 32 cases with high specificity (100 percent) and sensitivity. Conclusions: Contrast-enhanced ultrasound with three-dimensional image re-construction provides valuable preoperative perforator navigation. It detects precisely the perforator's location, its course, and the quality of its blood flow and allows the choice of the preferred perforator and the ideal donor site. Preoperative location of perforators using contrast-enhanced ultrasound with three-dimensional image reconstruction improves flap planning and eases flap harvesting. (Plast. Reconstr. Surg. 131: 80, 2013.)
引用
收藏
页码:80 / 93
页数:14
相关论文
共 50 条
  • [21] Three-dimensional Contrast-enhanced Ultrasound in Response Assessment for Breast Cancer: A Comparison with Dynamic Contrast-enhanced Magnetic Resonance Imaging and Pathology
    Wan-Ru Jia
    Lei Tang
    Deng-Bin Wang
    Wei-Min Chai
    Xiao-Chun Fei
    Jian-Rong He
    Man Chen
    Wen-Ping Wang
    Scientific Reports, 6
  • [22] Contrast-Enhanced Magnetic Resonance Angiography for Preoperative Imaging in DIEP Flap Breast Reconstruction
    Schaverien, Mark V.
    Ludman, Catherine N.
    Neil-Dwyer, Jason
    Perks, Graeme B.
    Akhtar, Nadeem
    Rodrigues, Jeremy N.
    Benetatos, Konstantinos
    Raurell, Anna
    Rasheed, Tuabin
    McCulley, Stephen J.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2011, 128 (01) : 56 - 62
  • [23] Contrast enhanced vascular three-dimensional ultrasound imaging
    Forsberg, F
    Rawool, NM
    Merton, DA
    Liu, JB
    Goldberg, BB
    ULTRASONICS, 2002, 40 (1-8) : 117 - 122
  • [24] Use of three-dimensional contrast-enhanced duplex ultrasound imaging during endovascular aneurysm repair
    Ormesher, David C.
    Lowe, Christopher
    Sedgwick, Nicola
    McCollum, Charles N.
    Ghosh, Jonathan
    JOURNAL OF VASCULAR SURGERY, 2014, 60 (06) : 1468 - 1472
  • [25] Accuracy and utility of three-dimensional contrast-enhanced magnetic resonance angiography in planning carotid stenting
    Timaran, Carlos H.
    Rosero, Eric B.
    Valentine, James
    Modrall, J. Gregory
    Smith, Stephen
    Clagett, Patrick
    JOURNAL OF VASCULAR SURGERY, 2007, 46 (02) : 257 - 263
  • [26] Error consideration in contrast-enhanced three-dimensional optical tomography
    Hawrysz, DJ
    Eppstein, MJ
    Lee, JW
    Sevick-Muraca, EM
    OPTICS LETTERS, 2001, 26 (10) : 704 - 706
  • [27] Three-Dimensional Reconstruction: The Waveform Design of Free Perforator Flap for the Heel Defect Repair
    Pan, Ding
    Zhou, Zheng-Bing
    Tang, Ju-Yu
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2018, 142 (05) : 809E - 810E
  • [28] Three-dimensional angiography of the submental artery perforator flap
    Tang, Maolin
    Ding, Maochao
    Almutairi, Khalid
    Morris, Steven F.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2011, 64 (05): : 608 - 613
  • [29] Equilibrium-Phase High Spatial Resolution Contrast-Enhanced MR Angiography at 1.5T in Preoperative Imaging for Perforator Flap Breast Reconstruction
    Versluis, Bas
    Tuinder, Stefania
    Boetes, Carla
    Van der Hulst, Rene
    Lataster, Arno
    Van Mulken, Tom
    Wildberger, Joachim
    de Haan, Michiel
    Leiner, Tim
    PLOS ONE, 2013, 8 (08):
  • [30] The evolution of facial artery perforator flap for midface reconstruction with preoperative ultrasound examination
    Malagon, Paloma
    Gonzalez, Jesus
    EUROPEAN JOURNAL OF PLASTIC SURGERY, 2022, 45 (06) : 933 - 939