Achieving high spatial and temporal resolution with perfusion MRI in the head and neck region using golden-angle radial sampling

被引:9
|
作者
Tomppert, Andrea [1 ]
Wuest, Wolfgang [1 ,2 ]
Wiesmueller, Marco [1 ]
Heiss, Rafael [1 ]
Kopp, Markus [1 ]
Nagel, Armin M. [1 ,3 ]
Tomita, Hayato [4 ]
Meixner, Christian [1 ,3 ]
Uder, Michael [1 ,2 ]
May, Matthias Stefan [1 ,2 ]
机构
[1] Univ Hosp Erlangen, Dept Radiol, Maximilianspl 3, D-91054 Erlangen, Germany
[2] Univ Hosp Erlangen, Imaging Sci Inst, Erlangen, Germany
[3] Friedrich Alexander Univ Erlangen Nurnberg FAU, Inst Med Phys, Erlangen, Germany
[4] St Marianna Univ, Dept Radiol, Sch Med, Miyamae Ku, Kawasaki, Kanagawa, Japan
关键词
Adult; Magnetic resonance imaging; Neck; Perfusion; SQUAMOUS-CELL CARCINOMA; CONTRAST-ENHANCED MRI; PAROTID TUMORS; DCE-MRI; RECONSTRUCTION; BENIGN;
D O I
10.1007/s00330-020-07263-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Conventional perfusion-weighted MRI sequences often provide poor spatial or temporal resolution. We aimed to overcome this problem in head and neck protocols using a golden-angle radial sparse parallel (GRASP) sequence. Methods We prospectively included 58 patients for examination on a 3.0-T MRI using a study protocol. GRASP (A) was applied to a volumetric interpolated breath-hold examination (VIBE) with 135 reconstructed pictures and high temporal (2.5 s) and spatial resolution (0.94 x 0.94 x 3.00 mm). Additional sequences of matching temporal resolution (B: 2.5 s, 1.88 x 1.88 x 3.00 mm), with a compromise between temporal and spatial resolution (C: 7.0 s, 1.30 x 1.30 x 3.00 mm) and with matching spatial resolution (D: 145 s, 0.94 x 0.94 x 3.00 mm), were subsequently without GRASP. Instant inline-image reconstructions (E) provided one additional series of averaged contrast information throughout the entire acquisition duration of A. Overall diagnostic image quality, edge sharpness and contrast of soft tissues, vessels and lesions were subjectively rated using 5-point Likert scales. Objective image quality was measured as contrast-to-noise ratio in D and E. Results Overall, the anatomic and pathologic image quality was substantially better with the GRASP sequence for the temporally (A/B/C, allp < 0.001) and spatially resolved comparisons (D/E, allp < 0.002 except lesion edge sharpness withp = 0.291). Image artefacts were also less likely to occur with GRASP. Differences in motion, aliasing and truncation were mainly significant, but pulsation and fat suppression were comparable. In addition, the contrast-to-noise ratio of E was significantly better than that of D (p(D-E) < 0.001). Conclusions High temporal and spatial resolution can be obtained synchronously using a GRASP-VIBE technique for perfusion evaluation in head and neck MRI.
引用
收藏
页码:2263 / 2271
页数:9
相关论文
共 50 条
  • [31] Achieving high spatial resolution and high SNR in low-field MRI of hyperpolarised gases with Slow Low Angle SHot
    Safiullin, Kajum
    Talbot, Cavin
    Nacher, Pierre-Jean
    JOURNAL OF MAGNETIC RESONANCE, 2013, 227 : 72 - 86
  • [32] Push-Pull Perfusion Sampling with Segmented Flow for High Temporal and Spatial Resolution in Vivo Chemical Monitoring
    Slaney, Thomas R.
    Nie, Jing
    Hershey, Neil D.
    Thwar, Prasanna K.
    Linderman, Jennifer
    Burns, Mark A.
    Kennedy, Robert T.
    ANALYTICAL CHEMISTRY, 2011, 83 (13) : 5207 - 5213
  • [33] Image quality optimization: dynamic contrast-enhanced MRI of the abdomen at 3T using a continuously acquired radial golden-angle compressed sensing acquisition
    Pan, Jiangyang
    Shao, Xian
    Liu, Hui
    Li, Yang
    Wang, Qi
    ABDOMINAL RADIOLOGY, 2024, 49 (02) : 399 - 405
  • [34] Image quality optimization: dynamic contrast-enhanced MRI of the abdomen at 3T using a continuously acquired radial golden-angle compressed sensing acquisition
    Jiangyang Pan
    Xian Shao
    Hui Liu
    Yang Li
    Qi Wang
    Abdominal Radiology, 2024, 49 : 399 - 405
  • [35] High-Spatial and High-Temporal Resolution Dynamic Contrast-Enhanced Perfusion Imaging of the Liver with Time-Resolved Three-Dimensional Radial MRI
    Brodsky, Ethan K.
    Bultman, Eric M.
    Johnson, Kevin M.
    Horng, Debra E.
    Schelman, William R.
    Block, Walter F.
    Reeder, Scott B.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 934 - 941
  • [36] Evaluation of Perfusion Change According to Pancreatic Cancer and Pancreatic Duct Dilatation Using Free-Breathing Golden-Angle Radial Sparse Parallel (GRASP) Magnetic Resonance Imaging
    Choi, Moonhyung
    Yoon, Seungbae
    Lee, Youngjoon
    Han, Dongyeob
    DIAGNOSTICS, 2023, 13 (04)
  • [37] Intraindividual Comparison between the Contrast-Enhanced Golden-Angle Radial Sparse Parallel Sequence and the Conventional Fat-Suppressed Contrast-Enhanced T1-Weighted Spin-Echo Sequence for Head and Neck MRI
    Hur, S-J
    Choi, Y.
    Yoon, J.
    Jang, J.
    Shin, N-Y
    Ahn, K-J
    Kim, B-S
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (11) : 2009 - 2015
  • [38] Multiecho pseudo-golden angle stack of stars thermometry with high spatial and temporal resolution using k-space weighted image contrast
    Svedin, Bryant T.
    Payne, Allison
    Bolster, Bradley D., Jr.
    Parker, Dennis L.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1407 - 1419
  • [39] "One-Stop Shop": Free-Breathing Dynamic Contrast-Enhanced Magnetic Resonance Imaging of the Kidney Using Iterative Reconstruction and Continuous Golden-Angle Radial Sampling
    Riffel, Philipp
    Zoellner, Frank G.
    Budjan, Johannes
    Grimm, Robert
    Block, Tobias K.
    Schoenberg, Stefan O.
    Hausmann, Daniel
    INVESTIGATIVE RADIOLOGY, 2016, 51 (11) : 714 - 719
  • [40] Quantitative Perfusion Analysis of the Rectum Using Golden-Angle Radial Sparse Parallel Magnetic Resonance Imaging Initial Experience and Comparison to Time-Resolved Angiography With Interleaved Stochastic Trajectories
    Attenberger, Ulrike I.
    Liu, Jing
    Riffel, Philipp
    Budjan, Johannes
    Grimm, Robert
    Block, Kai T.
    Schoenberg, Stefan O.
    Wang, Xiaoying
    Hausmann, Daniel
    INVESTIGATIVE RADIOLOGY, 2017, 52 (12) : 715 - 724