Achieving high spatial and temporal resolution with perfusion MRI in the head and neck region using golden-angle radial sampling

被引:9
|
作者
Tomppert, Andrea [1 ]
Wuest, Wolfgang [1 ,2 ]
Wiesmueller, Marco [1 ]
Heiss, Rafael [1 ]
Kopp, Markus [1 ]
Nagel, Armin M. [1 ,3 ]
Tomita, Hayato [4 ]
Meixner, Christian [1 ,3 ]
Uder, Michael [1 ,2 ]
May, Matthias Stefan [1 ,2 ]
机构
[1] Univ Hosp Erlangen, Dept Radiol, Maximilianspl 3, D-91054 Erlangen, Germany
[2] Univ Hosp Erlangen, Imaging Sci Inst, Erlangen, Germany
[3] Friedrich Alexander Univ Erlangen Nurnberg FAU, Inst Med Phys, Erlangen, Germany
[4] St Marianna Univ, Dept Radiol, Sch Med, Miyamae Ku, Kawasaki, Kanagawa, Japan
关键词
Adult; Magnetic resonance imaging; Neck; Perfusion; SQUAMOUS-CELL CARCINOMA; CONTRAST-ENHANCED MRI; PAROTID TUMORS; DCE-MRI; RECONSTRUCTION; BENIGN;
D O I
10.1007/s00330-020-07263-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Conventional perfusion-weighted MRI sequences often provide poor spatial or temporal resolution. We aimed to overcome this problem in head and neck protocols using a golden-angle radial sparse parallel (GRASP) sequence. Methods We prospectively included 58 patients for examination on a 3.0-T MRI using a study protocol. GRASP (A) was applied to a volumetric interpolated breath-hold examination (VIBE) with 135 reconstructed pictures and high temporal (2.5 s) and spatial resolution (0.94 x 0.94 x 3.00 mm). Additional sequences of matching temporal resolution (B: 2.5 s, 1.88 x 1.88 x 3.00 mm), with a compromise between temporal and spatial resolution (C: 7.0 s, 1.30 x 1.30 x 3.00 mm) and with matching spatial resolution (D: 145 s, 0.94 x 0.94 x 3.00 mm), were subsequently without GRASP. Instant inline-image reconstructions (E) provided one additional series of averaged contrast information throughout the entire acquisition duration of A. Overall diagnostic image quality, edge sharpness and contrast of soft tissues, vessels and lesions were subjectively rated using 5-point Likert scales. Objective image quality was measured as contrast-to-noise ratio in D and E. Results Overall, the anatomic and pathologic image quality was substantially better with the GRASP sequence for the temporally (A/B/C, allp < 0.001) and spatially resolved comparisons (D/E, allp < 0.002 except lesion edge sharpness withp = 0.291). Image artefacts were also less likely to occur with GRASP. Differences in motion, aliasing and truncation were mainly significant, but pulsation and fat suppression were comparable. In addition, the contrast-to-noise ratio of E was significantly better than that of D (p(D-E) < 0.001). Conclusions High temporal and spatial resolution can be obtained synchronously using a GRASP-VIBE technique for perfusion evaluation in head and neck MRI.
引用
收藏
页码:2263 / 2271
页数:9
相关论文
共 50 条
  • [21] Differentiation of Jugular Foramen Paragangliomas versus Schwannomas Using Golden-Angle Radial Sparse Parallel Dynamic Contrast-Enhanced MRI
    Pires, A.
    Nayak, G.
    Zan, E.
    Hagiwara, M.
    Gonen, O.
    Fatterpekar, G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (10) : 1847 - 1852
  • [22] Highly time-resolved 4D MR angiography using golden-angle radial sparse parallel (GRASP) MRI
    Goldman-Yassen, Adam E.
    Raz, Eytan
    Borja, Maria J.
    Chen, Duan
    Derman, Anna
    Dogra, Siddhant
    Block, Kai Tobias
    Dehkharghani, Seena
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [23] Highly time-resolved 4D MR angiography using golden-angle radial sparse parallel (GRASP) MRI
    Adam E. Goldman-Yassen
    Eytan Raz
    Maria J. Borja
    Duan Chen
    Anna Derman
    Siddhant Dogra
    Kai Tobias Block
    Seena Dehkharghani
    Scientific Reports, 12
  • [24] The application of quantitative perfusion analysis of golden-angle radial sparse parallel MRI and R2*value for predicting pathological prognostic factors in rectal cancer
    Zhou, M.
    Huang, H.
    Fan, Y.
    Chen, M.
    Li, M.
    Wang, Y.
    CLINICAL RADIOLOGY, 2024, 79 (02) : 124 - 132
  • [25] Free-breathing dynamic contrast-enhanced MRI for assessment of pulmonary lesions using golden-angle radial sparse parallel imaging
    Chen, Lihua
    Liu, Daihong
    Zhang, Jiuquan
    Xie, Bing
    Zhou, Xiaoyue
    Grimm, Robert
    Huang, Xuequan
    Wang, Jian
    Feng, Li
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (02) : 459 - 468
  • [26] Dynamic oxygen-17 MRI with adaptive temporal resolution using golden-means-based 3D radial sampling
    Gu, Yuning
    Gao, Huiyun
    Kim, Kihwan
    Liu, Yuchi
    Ramos-Estebanez, Ciro
    Luo, Yu
    Wang, Yunmei
    Yu, Xin
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (06) : 3112 - 3124
  • [27] Post-contrast T1-weighted spine 3T MRI in children using a golden-angle radial acquisition
    Houchun H. Hu
    Thomas Benkert
    Mark Smith
    Jeremy Y. Jones
    Aaron S. McAllister
    Jerome A. Rusin
    Ramkumar Krishnamurthy
    Kai Tobias Block
    Neuroradiology, 2019, 61 : 341 - 349
  • [28] Post-contrast T1-weighted spine 3T MRI in children using a golden-angle radial acquisition
    Hu, Houchun H.
    Benkert, Thomas
    Smith, Mark
    Jones, Jeremy Y.
    McAllister, Aaron S.
    Rusin, Jerome A.
    Krishnamurthy, Ramkumar
    Block, Kai Tobias
    NEURORADIOLOGY, 2019, 61 (03) : 341 - 349
  • [29] Respiratory Motion Prediction Using Fusion-Based Multi-Rate Kalman Filtering and Real-Time Golden-Angle Radial MRI
    Li, Xinzhou
    Lee, Yu-Hsiu
    Mikaiel, Samantha
    Simonelli, James
    Tsao, Tsu-Chin
    Wu, Holden H.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (06) : 1727 - 1738
  • [30] Comparison of golden-angle radial sparse parallel (GRASP) and conventional cartesian sampling in 3D dynamic contrast-enhanced mri for bladder cancer: a preliminary study
    Ueno, Yoshiko
    Sofue, Keitaro
    Tamada, Tsutomu
    Takeuchi, Mitsuru
    Ebisu, Naoya
    Nishiuchi, Kentaro
    Hara, Takuto
    Hyodo, Toshiki
    Miyake, Hideaki
    Murakami, Takamichi
    JAPANESE JOURNAL OF RADIOLOGY, 2024, : 1469 - 1478