The Final Surface Treatment Effect on Performance of CdZnTe Frisch Collar Gamma Ray Detectors

被引:0
|
作者
Kargar, Alireza [1 ]
Brooks, Adam C. [1 ]
Kohman, Kyle T. [1 ]
Lowell, Rans B. [1 ]
Keyes, Roger C. [1 ]
Chen, Henry [2 ]
Awadalla, Salah [2 ]
Bindley, Glenn [2 ]
McGregor, Douglas S. [1 ]
机构
[1] Kansas State Univ, Mech & Nuc Eng Dep, SMART Lab, Manhattan, KS 66506 USA
[2] Redlen Technol, Sidney, BC, Canada
关键词
CdZnTe detector; Frisch collar device; Surface treatment; passivation;
D O I
10.1117/12.795366
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Surface passivation and final surface treatment on the lateral sides of CdZnTe/CdTe gamma ray detectors have been studied by many research groups. However, systematic studies of spectroscopic performance and the current voltage (I-V) characteristic behavior of devices as a result of surface treatments have not been conducted. Additionally, few studies report results for high energy gamma ray detection, which requires different techniques and technologies. In this study, a variety of final surface treatments and oxidizing agents have been applied on different CdZnTe detectors, and the effects on the I-V characteristic behavior and spectral performance of Frisch collar devices at 662 keV are reported. Further, the possibility of an alternative method is investigated, in which ion milling is utilized to etch the lateral surfaces with energetic ions of Xenon. The process is described in detail and the challenges are presented. Electron Microprobe (EMP) technique was performed on the device sides to determine the surface elements using Energy Dispersive Spectroscopy (EDS) before and after each treatment. The CdZnTe materials for this study were acquired from Redlen Technologies, and the CdZnTe devices were fabricated and characterized for each treatment at the S.M.A.R.T. Laboratory at Kansas State University.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Fabrication of high performance CdZnTe quasi-hemispherical gamma-ray CAPture™ plus detectors
    Szeles, Csaba
    Bale, Derek
    Grosholz, Joseph, Jr.
    Smith, Gary L.
    Blostein, Michael
    Eger, John
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS AND PENETRATING RADIATION SYSTEMS VIII, 2006, 6319
  • [42] Effects of Chemomechanical Polishing on CdZnTe X-ray and Gamma-Ray Detectors
    Stephen U. Egarievwe
    Anwar Hossain
    Ifechukwude O. Okwechime
    Rubi Gul
    Ralph B. James
    Journal of Electronic Materials, 2015, 44 : 3194 - 3201
  • [43] Effects of Chemical Treatments on CdZnTe X-Ray and Gamma-Ray Detectors
    Egarievwe, Stephen U.
    Hossain, Anwar
    Okwechime, Ifechukwude O.
    Egarievwe, Alexander A.
    Jones, Dominique E.
    Roy, Utpal N.
    James, Ralph B.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (02) : 1091 - 1098
  • [44] CdTe and CdZnTe X-ray and gamma-ray detectors for imaging systems
    Eisen, Y
    Shor, A
    Mardor, I
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3311 - 3319
  • [45] A 4 x 4 array module of position-sensitive virtual Frisch-grid CdZnTe detectors for gamma-ray imaging spectrometers
    Bolotnikov, A. E.
    Camarda, G. S.
    De Geronimo, G.
    Fried, J.
    Hodges, D.
    Hossain, A.
    Kim, K.
    Mahler, G.
    Giraldo, L. Ocampo
    Vernon, E.
    Yang, G.
    James, R. B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954
  • [46] New developments in CdTe and CdZnTe detectors for x and gamma-ray applications
    Veger, L
    Bonnefoy, JP
    Glasser, F
    OuvrierBuffet, P
    JOURNAL OF ELECTRONIC MATERIALS, 1997, 26 (06) : 738 - 744
  • [47] CdZnTe detectors for gamma-ray Burst ArcSecond Imaging and Spectroscopy (BASIS)
    Stahle, CM
    Palmer, D
    Bartlett, LM
    Parsons, A
    Shi, ZQ
    Lisse, CM
    Sappington, C
    Cao, N
    Shu, P
    Gehrels, N
    Teegarden, B
    Birsa, F
    Singh, S
    Odom, J
    Hanchak, C
    Tueller, J
    Barthelmy, S
    Krizmanic, J
    Barbier, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 486 - 489
  • [48] CdTe and CdZnTe materials for room-temperature X-ray and gamma ray detectors
    Eisen, Y
    Shor, A
    JOURNAL OF CRYSTAL GROWTH, 1998, 184 : 1302 - 1312
  • [49] Characterisation of Pixellated CdZnTe Detectors for Use in a Portable Gamma-Ray Spectrometer
    Rigby, S. V.
    Boston, A. J.
    Nolan, P. J.
    Petts, A.
    Oxley, D.
    Lazarus, I.
    Letts, S.
    Simpson, J.
    Pucknell, V.
    Seller, P.
    Cullen, D. M.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3598 - 3601
  • [50] Charge sharing on monolithic CdZnTe gamma-ray detectors:: A simulation study
    d'Aillon, Eric Gros
    Tabary, Joachim
    Gliere, Alain
    Verger, Loick
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 124 - 127