The Final Surface Treatment Effect on Performance of CdZnTe Frisch Collar Gamma Ray Detectors

被引:0
|
作者
Kargar, Alireza [1 ]
Brooks, Adam C. [1 ]
Kohman, Kyle T. [1 ]
Lowell, Rans B. [1 ]
Keyes, Roger C. [1 ]
Chen, Henry [2 ]
Awadalla, Salah [2 ]
Bindley, Glenn [2 ]
McGregor, Douglas S. [1 ]
机构
[1] Kansas State Univ, Mech & Nuc Eng Dep, SMART Lab, Manhattan, KS 66506 USA
[2] Redlen Technol, Sidney, BC, Canada
关键词
CdZnTe detector; Frisch collar device; Surface treatment; passivation;
D O I
10.1117/12.795366
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Surface passivation and final surface treatment on the lateral sides of CdZnTe/CdTe gamma ray detectors have been studied by many research groups. However, systematic studies of spectroscopic performance and the current voltage (I-V) characteristic behavior of devices as a result of surface treatments have not been conducted. Additionally, few studies report results for high energy gamma ray detection, which requires different techniques and technologies. In this study, a variety of final surface treatments and oxidizing agents have been applied on different CdZnTe detectors, and the effects on the I-V characteristic behavior and spectral performance of Frisch collar devices at 662 keV are reported. Further, the possibility of an alternative method is investigated, in which ion milling is utilized to etch the lateral surfaces with energetic ions of Xenon. The process is described in detail and the challenges are presented. Electron Microprobe (EMP) technique was performed on the device sides to determine the surface elements using Energy Dispersive Spectroscopy (EDS) before and after each treatment. The CdZnTe materials for this study were acquired from Redlen Technologies, and the CdZnTe devices were fabricated and characterized for each treatment at the S.M.A.R.T. Laboratory at Kansas State University.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Effect of surfaces on the performance of CdZnTe detectors
    Prettyman, TH
    Ameduri, FP
    Burger, A
    Gregory, JC
    Hoffbauer, MA
    Majerus, PR
    Reisenfeld, DB
    Soldner, SA
    Szeles, C
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS III, 2001, 4507 : 23 - 31
  • [22] High-Efficiency CdZnTe Gamma-Ray Detectors
    Bolotnikov, A. E.
    Ackley, K.
    Camarda, G. S.
    Cui, Y.
    Eger, J. F.
    De Geronimo, G.
    Finfrock, C.
    Fried, J.
    Hossain, A.
    Lee, W.
    Prokesch, M.
    Petryk, M.
    Reiber, J. L.
    Roy, U.
    Vernon, E.
    Yang, G.
    James, R. B.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (06) : 3193 - 3198
  • [23] Study of Surface Passivation and Contact Deposition Techniques in CdZnTe X-Ray and Gamma-Ray Detectors
    Jones, Dominique E.
    Egarievwe, Stephen U.
    Hossain, Anwar
    Okwechime, Ifechukwude O.
    Drabo, Mebougna L.
    Hall, JaQueeta
    Adams, Aaron L.
    Babalola, Stephen O.
    Camarda, Giuseppe S.
    Bolotnikov, Aleksey E.
    Chan, Wing
    James, Ralph B.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 4124 - 4127
  • [24] The spatial response of CdZnTe gamma-ray detectors as measured by gamma-ray mapping
    Brunett, BA
    Van Scyoc, JM
    Schlesinger, TE
    James, RB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 76 - 84
  • [25] X-Ray Performance of Pixilated CdZnTe Detectors
    Wilson, Matthew D.
    Seller, Paul
    Hansson, Conny
    Cernik, Robert
    Marchal, Julien
    Xin, Zhi-Jun
    Perumal, Veeramani
    Veale, Matthew C.
    Sellin, Paul
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5046 - +
  • [26] CdTe and CdZnTe crystals for room temperature gamma-ray detectors
    Franc, J
    Höschl, P
    Belas, E
    Grill, R
    Hlídek, P
    Moravec, P
    Bok, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 434 (01): : 146 - 151
  • [27] CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems
    Eisen, Y
    Shor, A
    Mardor, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (01): : 158 - 170
  • [28] Effect of Te precipitates on the performance of CdZnTe detectors
    Carini, GA
    Bolotnikov, AE
    Camarda, GS
    Wright, GW
    James, RB
    Li, L
    APPLIED PHYSICS LETTERS, 2006, 88 (14)
  • [29] CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems
    Soreq NRC, 81800 Yavne, Israel
    Nucl Instrum Methods Phys Res Sect A, 1 (158-170):
  • [30] Multi-element CdZnTe detectors for gamma ray detection and imaging
    Bennett, PR
    Shah, KS
    Cirignano, LJ
    Klugerman, MB
    Dmitryev, YN
    Squillante, MR
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 561 - 564