Near real-time notification of gaps in cuff blood pressure recordings for improved patient monitoring

被引:11
|
作者
Nair, Bala G. [1 ]
Horibe, Mayumi [2 ]
Newman, Shu-Fang [3 ]
Wu, Wei-Ying [4 ]
Schwid, Howard A. [1 ]
机构
[1] Univ Washington, Dept Anesthesiol & Pain Med, Seattle, WA 98195 USA
[2] VA Puget Sound Hlth Care Syst, Dept Anesthesiol, Seattle, WA USA
[3] Univ Washington, Patient Care Serv, Seattle, WA 98195 USA
[4] Natl Dong Hwa Univ, Dept Appl Math, Hualien, Taiwan
关键词
Decision support; Anesthesia information management system; Patient monitoring; Blood pressure monitoring; Real-time reminders; INFORMATION-MANAGEMENT SYSTEM; DOCUMENTATION; QUALITY;
D O I
10.1007/s10877-012-9425-2
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Blood pressure monitoring during anesthesia is an American Society of Anesthesiology standard. However, the anesthesia provider sometimes fails to engage the patient monitor to make periodic (generally every 3-5 min) measurements of Non-Invasive Blood Pressure (NIBP), which can lead to extended periods (> 5 min) when blood pressure is not monitored. We describe a system to automatically detect such gaps in NIBP measurement and notify clinicians in real-time to initiate measurement. We applied a decision support system called the Smart Anesthesia Messenger (SAM) to notify the anesthesia provider if NIBP measurements have not been made in the last 7 min. Notification messages were generated only if direct arterial blood pressure was not being monitored. NIBP gaps were analyzed for 9 months before and after SAM notification was initiated (12,000 cases for each period). SAM notification was able to reduce the occurrence of extended NIBP gaps > 15 min from 15.7 +/- A 4.5 to 6.7 +/- A 2.0 instances per 1,000 cases (p < 0.001). In addition, for extended gaps (> 15 min) the mean gap duration declined from 23.1 +/- A 2.0 to 18.6 +/- A 1.1 min after SAM notification was initiated (p < 0.001). However, for 7-15 min gaps, SAM notification was not effective in reducing the occurrence. The maximum gap encountered before SAM was 64 min, while it was 27 min with SAM notification. Real-time notification using SAM is an effective way to reduce both the number of instances and the duration of inadvertent, extended (> 15 min) gaps in blood pressure measurements in the operating room. However, the frequency of gaps < 15 min could not be reduced using the current configuration of SAM.
引用
收藏
页码:265 / 271
页数:7
相关论文
共 50 条
  • [41] Near Real-Time Monitoring of Significant Sea Wave Height through Microseism Recordings: Analysis of an Exceptional Sea Storm Event
    Cutroneo, Laura
    Ferretti, Gabriele
    Barani, Simone
    Scafidi, Davide
    De Leo, Francesco
    Besio, Giovanni
    Capello, Marco
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2021, 9 (03)
  • [42] Real-Time Pore Pressure Detection: Indicators and Improved Methods
    Zhang, Jincai
    Yin, Shangxian
    GEOFLUIDS, 2017,
  • [43] Plantar Pressure Monitoring by Developing a Real-Time Wireless System
    Saeedi, Ali
    Almasganj, Farshad
    Pourebrahim, Malike
    2014 21TH IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING (ICBME), 2014, : 211 - 214
  • [44] Near Real-Time Estimation of Blood Loss and Flow-Pressure Redistribution during Unilateral Nephrectomy
    Cowley, James
    Kyeremeh, Justicia
    Stewart, Grant D.
    Luo, Xichun
    Shu, Wenmiao
    Kazakidi, Asimina
    FLUIDS, 2024, 9 (09)
  • [45] Combined NIRS-EEG Remote Recordings for Epilepsy and Stroke Real-Time Monitoring
    Sawan, Mohamad
    Salam, Muhammad T.
    Gelinas, Sebastien
    Le Lan, Jerome
    Lesage, Frederic
    Nguyen, Dang K.
    2012 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS 2012), 2012, : 13 - 16
  • [46] REAL-TIME MEASUREMENTS OF BIOMARKERS FOR GRAFT ASSESSMENT AND PATIENT MONITORING
    Huwyler, Florian
    Eden, Janina
    Binz, Jonas
    Cunningham, Leslie
    Da Silva, Richard Sousa
    Hefti, Max
    Clavien, Pierre A.
    Dutkowski, Philipp
    Tibbitt, Mark William
    HEPATOLOGY, 2023, 78 : S236 - S236
  • [47] Realistic model for temporal reasoning in real-time patient monitoring
    INSERM, Creteil, France
    Appl Artif Intell, 2 (121-143):
  • [48] A Real-Time, Wireless Pressure Monitoring System for Bucking Bulls
    Li, Siyu
    Wang, Ning
    Gao, Hongju
    Pang, Shujie
    2012 INTERNATIONAL WORKSHOP ON INFORMATION AND ELECTRONICS ENGINEERING, 2012, 29 : 2809 - 2813
  • [49] A chest drainage system with a real-time pressure monitoring device
    Chen, Chih-Hao
    Liu, Tsang-Pai
    Chang, Ho
    Huang, Tung-Sung
    Liu, Hung-Chang
    Chen, Chao-Hung
    JOURNAL OF THORACIC DISEASE, 2015, 7 (07) : 1119 - 1124
  • [50] A Novel Sensor for Real-Time Pressure Monitoring in Colonoscopy Training
    Vajpeyi, Anirudh
    Naidu, Anish S.
    Hawel, Jeffrey D. E.
    Schlachta, Christopher M.
    Patel, Rajni V.
    2023 IEEE SENSORS, 2023,