Near real-time notification of gaps in cuff blood pressure recordings for improved patient monitoring

被引:11
|
作者
Nair, Bala G. [1 ]
Horibe, Mayumi [2 ]
Newman, Shu-Fang [3 ]
Wu, Wei-Ying [4 ]
Schwid, Howard A. [1 ]
机构
[1] Univ Washington, Dept Anesthesiol & Pain Med, Seattle, WA 98195 USA
[2] VA Puget Sound Hlth Care Syst, Dept Anesthesiol, Seattle, WA USA
[3] Univ Washington, Patient Care Serv, Seattle, WA 98195 USA
[4] Natl Dong Hwa Univ, Dept Appl Math, Hualien, Taiwan
关键词
Decision support; Anesthesia information management system; Patient monitoring; Blood pressure monitoring; Real-time reminders; INFORMATION-MANAGEMENT SYSTEM; DOCUMENTATION; QUALITY;
D O I
10.1007/s10877-012-9425-2
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Blood pressure monitoring during anesthesia is an American Society of Anesthesiology standard. However, the anesthesia provider sometimes fails to engage the patient monitor to make periodic (generally every 3-5 min) measurements of Non-Invasive Blood Pressure (NIBP), which can lead to extended periods (> 5 min) when blood pressure is not monitored. We describe a system to automatically detect such gaps in NIBP measurement and notify clinicians in real-time to initiate measurement. We applied a decision support system called the Smart Anesthesia Messenger (SAM) to notify the anesthesia provider if NIBP measurements have not been made in the last 7 min. Notification messages were generated only if direct arterial blood pressure was not being monitored. NIBP gaps were analyzed for 9 months before and after SAM notification was initiated (12,000 cases for each period). SAM notification was able to reduce the occurrence of extended NIBP gaps > 15 min from 15.7 +/- A 4.5 to 6.7 +/- A 2.0 instances per 1,000 cases (p < 0.001). In addition, for extended gaps (> 15 min) the mean gap duration declined from 23.1 +/- A 2.0 to 18.6 +/- A 1.1 min after SAM notification was initiated (p < 0.001). However, for 7-15 min gaps, SAM notification was not effective in reducing the occurrence. The maximum gap encountered before SAM was 64 min, while it was 27 min with SAM notification. Real-time notification using SAM is an effective way to reduce both the number of instances and the duration of inadvertent, extended (> 15 min) gaps in blood pressure measurements in the operating room. However, the frequency of gaps < 15 min could not be reduced using the current configuration of SAM.
引用
收藏
页码:265 / 271
页数:7
相关论文
共 50 条
  • [31] Near real-time event detection for watershed monitoring with CANARY
    Burkhardt, Jonathan B.
    Sahoo, Debabrata
    Hammond, Benjamin
    Long, Michael
    Haxton, Terranna
    Murray, Regan
    ENVIRONMENTAL SCIENCE-ADVANCES, 2022, 1 (02): : 170 - 181
  • [32] Real-time monitoring of distillations by near-infrared spectroscopy
    Pasquini, C
    Scafi, SHF
    ANALYTICAL CHEMISTRY, 2003, 75 (10) : 2270 - 2275
  • [33] Near real-time monitoring of gas phase atmospheric species
    Nguyen, A
    Reeve, SW
    Burns, WA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U457 - U457
  • [34] Derivation of near real-time TEC for monitoring ionospheric disturbances
    School of Engeneering, Department of Aeronautics and Astronautics, Tokai University, Japan
    不详
    J. Natl. Inst. Inf. Commun. Technol., 2009, 1-4 (377-389): : 377 - 389
  • [35] A real-time algorithm for the quantification of blood pressure waveforms
    Navakatikyan, MA
    Barrett, CJ
    Head, GA
    Ricketts, JH
    Malpas, SC
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (07) : 662 - 670
  • [36] Use of an automated notification tool to drive real-time patient symptom intervention.
    Hartman, Scott
    Bosch, Brandon
    Denny, Diane
    Markman, Maurie
    JOURNAL OF CLINICAL ONCOLOGY, 2016, 34 (07)
  • [37] An Interfacing Digital Blood Pressure Meter with Arduino-GSM Module for Real-time Monitoring
    Fajar, Zulfikar M. R.
    Hadiyoso, Sugondo
    Rizal, Achmad
    2017 INTERNATIONAL CONFERENCE ON CONTROL, ELECTRONICS, RENEWABLE ENERGY AND COMMUNICATIONS (ICCREC), 2017, : 98 - 102
  • [38] IMPROVED CEMENTING SUCCESS THROUGH REAL-TIME JOB MONITORING
    SMITH, RC
    JOURNAL OF PETROLEUM TECHNOLOGY, 1986, 38 (07): : 619 - 620
  • [39] An improved method for engraftment monitoring using real-time PCR
    McLanghlin, I. J.
    Bost, D. A.
    Mountain, J. L.
    McGinnis, I. D.
    Krausa, P.
    BIOLOGY OF BLOOD AND MARROW TRANSPLANTATION, 2007, 13 (02) : 95 - 95
  • [40] Improved Method for Real-Time Fluence Monitoring in UV Reactors
    Li, Mengkai
    Qiang, Zhimin
    Bolton, James R.
    Li, Wentao
    Wang, Chen
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2015, 141 (04)