Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference

被引:2
|
作者
Sharma, Utkarsh [1 ]
Kang, Jin U. [2 ]
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
[2] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
关键词
D O I
10.3788/COL20080612.0910
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The objective of this study is to demonstrate that tensile stress resulting due to applied force on cornea can be accurately measured by using a time-domain common-path optical coherence tomography (OCT) system with an external contact reference. The unique design of the common-path OCT is utilized to set up an imaging system in which a chicken eye is placed adjacent to a glass plate serving as the external reference plane for the imaging system. As the force is applied to the chicken eye, it presses against the reference glass plate. The modified OCT image obtained is used to calculate the size of contact area, which is then used to derive the tensile stress on the cornea. The drop in signal levels upon contact of reference glass plate with the tissue are extremely sharp because of the sharp decline in reference power levels itself, thus providing us with an accurate measurement of contact area. The experimental results were in good agreement with the numerical predictions. The results of this study might be useful in providing new insights and ideas to improve the precision and safety of currently used ophthalmic surgical techniques. This research outlines a method which could be used to provide high resolution OCT images and a precise feedback of the forces applied to the cornea simultaneously.
引用
收藏
页码:910 / 912
页数:3
相关论文
共 50 条
  • [31] Handheld optical coherence tomography scanner using a common-path probing arm with long working distance
    Zhou, Song
    Yang, Wen
    Wang, Yimin
    Chen, Zhong
    Yuan, Tianran
    OPTICS COMMUNICATIONS, 2021, 499
  • [32] 70 μm diameter optical probe for common-path optical coherence tomography in air and liquids
    Marrese, Marica
    Offerhaus, Hidde
    Paardekam, Erik
    Iannuzzi, Davide
    OPTICS LETTERS, 2018, 43 (24) : 5929 - 5932
  • [33] Fourier Domain Common-Path Optical Coherence Tomography with a Conduit Fiber Bundle Probe
    Han, Jae-Ho
    Liu, Xuan
    Song, Chul Gyu
    Kang, Jin U.
    2009 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1AND 2, 2009, : 205 - 206
  • [34] A Surface Topology and Motion Compensation System for Microsurgery Guidance and Intervention Based on Common-Path Optical Coherence Tomography
    Zhang, Kang
    Wang, Weichao
    Han, Jaeho
    Kang, Jin U.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (09) : 2318 - 2321
  • [35] Common-path optical coherence tomography guided fibre probe for spatially precise optical nerve stimulation
    Zhang, K.
    Katz, E.
    Kim, D. H.
    Kang, J. U.
    Ilev, I. K.
    ELECTRONICS LETTERS, 2010, 46 (02) : 118 - 119
  • [36] Spectrally encoded common-path fiber-optic-based parallel optical coherence tomography
    Lee, Kye-Sung
    Hur, Hwan
    Sung, Ha-Young
    Kim, I. Jong
    Kim, Geon-Hee
    OPTICS LETTERS, 2016, 41 (18) : 4241 - 4244
  • [37] Common-path diffraction optical tomography with a low-coherence illumination for reducing speckle noise
    Shin, Seungwoo
    Kim, Youngchan
    Lee, KyeoReh
    Kim, Kyoohyun
    Kim, Young-Jin
    Park, HyunJoo
    Park, YongKeun
    QUANTITATIVE PHASE IMAGING, 2015, 9336
  • [38] High-speed cross-sectional imaging of valuable documents using common-path swept-source optical coherence tomography
    Fujiwara, Kazuo
    Matoba, Osamu
    APPLIED OPTICS, 2011, 50 (34) : H165 - H170
  • [39] Quantitative measurements of strain and birefringence with common-path polarization-sensitive optical coherence tomography
    Marvdashti, Tahereh
    Duan, Lian
    Lurie, Kristen L.
    Smith, Gennifer T.
    Ellerbee, Audrey K.
    OPTICS LETTERS, 2014, 39 (19) : 5507 - 5510
  • [40] High-resolution subsurface articular cartilage imaging based on Fourier-domain common-path optical coherence tomography
    Han, Jae-Ho
    Liu, Xuan
    Kang, Jin U.
    Song, Chul Gyu
    CHINESE OPTICS LETTERS, 2010, 8 (02) : 167 - 169