RELIABILITY ANALYSIS FOR PASSIVE CONTAINMENT COOLING SYSTEM IN SEISMIC HAZARD

被引:0
|
作者
Yu, Yu [1 ]
Wang, Shengfei [1 ]
Lv, Xuefeng [1 ]
Niu, Fenglei [1 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing, Peoples R China
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Passive containment cooling system is an important safety-related system in AP 1000 nuclear power plant, by which heat produced in reactor is transferred to the heat sink -- atmosphere based on natural circulation. So it is important to the plant safety whether the system can work well or not in the seismic hazard. Since the system operation is independent of human interfere or the operation of outside equipments, the reliability of the system is improved, however, physical process failure become one of the important contributors to the system operation failure because natural circulation may not keep when the system configuration is different from the design. So it is necessary to analyze the system reliability in seismic situation. The equipment failure probability under earthquake is a function of the peak ground acceleration which is stochastic, and the fault tree method used in traditional probability safety assessment (PSA) for system reliability analysis is not power enough to deal with conditional probability. In this paper, a new analysis method for system reliability evaluate at seismic situation based on Monte Carlo (MC) simulation is put forward, and annual failure probability of passive containment cooling system in AP 1000 in seismic hazard is calculated, the result is according with the AP 1000 seismic margin evaluation.
引用
收藏
页码:485 / 489
页数:5
相关论文
共 50 条
  • [21] Effects of outlet height on passive containment cooling system
    Liu, Youhong
    Sun, Mingyue
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2015, 27 (12):
  • [22] The Outside Transport Phenomena of the Passive Containment Cooling System
    Li, Cheng
    Fan, Huanran
    Zhao, Ruichang
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2013, VOL 4, 2014,
  • [23] Analysis of large scale tests for AP-600 passive containment cooling system
    Sha, WT
    Chien, TH
    Sun, JG
    Chao, BT
    PROCEEDINGS OF THE INTERNATIONAL TOPICAL MEETING ON ADVANCED REACTORS SAFETY, VOLS 1 AND 2, 1997, : 199 - 216
  • [24] THERMAL - HYDRAULIC PERFORMANCE ANALYSIS FOR AP1000 PASSIVE CONTAINMENT COOLING SYSTEM
    Yu, Yu
    Wang, Shengfei
    Niu, Fenglei
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 4, 2014,
  • [25] Thermal-hydraulic Analysis of Passive Containment Cooling System of HPR1000
    Qiu J.
    Wu J.
    Tian W.
    Wang Z.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2020, 54 (01): : 72 - 80
  • [26] Optimal design of passive containment cooling system for innovative PWR
    Ha, Huiun
    Lee, Sangwon
    Kim, Hangon
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2017, 49 (05) : 941 - 952
  • [27] AEROSOL REMOVAL BY A HEAT EXCHANGER OF PASSIVE CONTAINMENT COOLING SYSTEM
    Liang, Yangyang
    Lu, Junjing
    Zhang, Tianqi
    Han, Xu
    Yuan, Yidan
    PROCEEDINGS OF 2021 28TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING (ICONE28), VOL 2, 2021,
  • [28] Design of water distribution device for passive containment cooling system
    Zhang, Ting-Xiang
    Tang, Yu
    Hedongli Gongcheng/Nuclear Power Engineering, 2002, 23 (SUPPL.): : 103 - 106
  • [29] Experimental study on transient characteristic of passive containment cooling system
    Cheng Cheng
    Wen Qing-long
    Wu Xiao-hang
    Li Yu
    Ju Peng
    INTERNATIONAL YOUTH NUCLEAR CONGRESS 2016, IYNC2016, 2017, 127 : 193 - 200
  • [30] A simplified model of Passive Containment Cooling System in a CFD code
    Jiang, X. W.
    Studer, E.
    Kudriakov, S.
    NUCLEAR ENGINEERING AND DESIGN, 2013, 262 : 579 - 588