Reliability of contour-based volume calculation for radiosurgery

被引:11
|
作者
Ma, Lijun [1 ]
Sahgal, Arjun
Nie, Ke [1 ]
Hwang, Andrew [1 ]
Karotki, Aliaksandr [4 ]
Wang, Brian [3 ]
Shrieve, Dennis C. [3 ]
Sneed, Penny K. [1 ]
McDermott, Michael [1 ]
Larson, David A. [1 ,2 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
[2] Washington Fremont Hosp, Gamma Knife Ctr, Fremont, CA USA
[3] Univ Utah, Dept Radiat Oncol, Salt Lake City, UT USA
[4] Univ Toronto, Dept Radiat Oncol, Sunnybrook Odette Canc Ctr, Princess Margaret Hosp, Toronto, ON M5S 1A1, Canada
关键词
volume calculation; volume reconstruction; stereotactic radiosurgery; treatment planning; BRAIN METASTASES; STEREOTACTIC RADIOSURGERY; RADIATION-THERAPY; TUMORS; CONFORMITY; SYSTEM;
D O I
10.3171/2012.7.GKS121016
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Determining accurate target volume is critical for both prescribing and evaluating stereotactic radiosurgery (SRS) treatments. The aim of this study was to determine the reliability of contour-based volume calculations made by current major SRS platforms. Methods. Spheres ranging in diameter from 6.4 to 38.2 mm were scanned and then delineated on imaging studies. Contour data sets were subsequently exported to 6 SRS treatment-planning platforms for volume calculations and comparisons. This procedure was repeated for the case of a patient with 12 metastatic lesions distributed throughout the brain. Both the phantom and patient datasets were exported to a stand-alone workstation for an independent volume-calculation analysis using a series of 10 algorithms that included approaches such as slice stacking, surface meshing, point-cloud filling, and so forth. Results. Contour data rendered volumes exhibited large variations across the current SRS platforms investigated for both the phantom (-3.6% to 22%) and patient case (1.0%-10.2%). The majority of the clinical SRS systems and algorithms overestimated the volumes of the spheres, compared with their known physical volumes. An independent algorithm analysis found a similar trend in variability, and large variations were typically associated with small objects whose volumes were < 0.4 cm(3) and with those objects located near the end-slice of the scan limits. Conclusions. Significant variations in volume calculation were observed based on data obtained from the SRS systems that were investigated. This observation highlights the need for strict quality assurance and benchmarking efforts when commissioning SRS systems for clinical use and, moreover, when conducting multiinstitutional cross-SRS platform clinical studies. (http://thejns.org/doi/abs/10.3171/2012.7.GKS121016)
引用
收藏
页码:203 / 210
页数:8
相关论文
共 50 条
  • [41] SEM contour-based OPC model calibration
    Bailey, George E.
    MICROLITHOGRAPHY WORLD, 2007, 16 (02): : 9 - +
  • [42] A Contour-based Progressive Technique for Shape Recognition
    Ferilli, Stefano
    Basile, Teresa M. A.
    Esposito, Floriana
    Biba, Marenglen
    11TH INTERNATIONAL CONFERENCE ON DOCUMENT ANALYSIS AND RECOGNITION (ICDAR 2011), 2011, : 723 - 727
  • [43] Improved Contour-Based Object Detection and Segmentation
    Lin Kezheng
    Li Xinyuan
    2008 INTERNATIONAL MULTISYMPOSIUMS ON COMPUTER AND COMPUTATIONAL SCIENCES (IMSCCS), 2008, : 172 - 175
  • [44] Contour-based Historical Building Image Matching
    Wu, Gang
    Wang, Zhaohe
    Li, Jialin
    Yu, Zhihui
    Qiao, Baiyou
    ISICDM 2018: PROCEEDINGS OF THE 2ND INTERNATIONAL SYMPOSIUM ON IMAGE COMPUTING AND DIGITAL MEDICINE, 2018, : 32 - 36
  • [45] FINDING CONTOUR-BASED ABSTRACTIONS OF PLANAR PATTERNS
    ARCELLI, C
    RAMELLA, G
    PATTERN RECOGNITION, 1993, 26 (10) : 1563 - 1577
  • [46] A CONTOUR-BASED APPROACH TO MULTISENSOR IMAGE REGISTRATION
    LI, H
    MANJUNATH, BS
    MITRA, SK
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 1995, 4 (03) : 320 - 334
  • [47] Performance Comparisons of Contour-Based Corner Detectors
    Awrangjeb, Mohammad
    Lu, Guojun
    Fraser, Clive S.
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2012, 21 (09) : 4167 - 4179
  • [48] Contour-based Multidirectional Intra Coding for HEVC
    Laude, Thorsten
    Ostermann, Joern
    2016 PICTURE CODING SYMPOSIUM (PCS), 2016,
  • [49] Contextual Inference in Contour-Based Stereo Correspondence
    Gang Li
    Steven W. Zucker
    International Journal of Computer Vision, 2006, 69 : 59 - 75
  • [50] Image denoising with contour-based directionlet transform
    Xu, Huanan
    Peng, Guohua
    Liu, Zhe
    APPLIED SCIENCE, MATERIALS SCIENCE AND INFORMATION TECHNOLOGIES IN INDUSTRY, 2014, 513-517 : 3607 - 3611