Reliability of contour-based volume calculation for radiosurgery

被引:11
|
作者
Ma, Lijun [1 ]
Sahgal, Arjun
Nie, Ke [1 ]
Hwang, Andrew [1 ]
Karotki, Aliaksandr [4 ]
Wang, Brian [3 ]
Shrieve, Dennis C. [3 ]
Sneed, Penny K. [1 ]
McDermott, Michael [1 ]
Larson, David A. [1 ,2 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
[2] Washington Fremont Hosp, Gamma Knife Ctr, Fremont, CA USA
[3] Univ Utah, Dept Radiat Oncol, Salt Lake City, UT USA
[4] Univ Toronto, Dept Radiat Oncol, Sunnybrook Odette Canc Ctr, Princess Margaret Hosp, Toronto, ON M5S 1A1, Canada
关键词
volume calculation; volume reconstruction; stereotactic radiosurgery; treatment planning; BRAIN METASTASES; STEREOTACTIC RADIOSURGERY; RADIATION-THERAPY; TUMORS; CONFORMITY; SYSTEM;
D O I
10.3171/2012.7.GKS121016
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Determining accurate target volume is critical for both prescribing and evaluating stereotactic radiosurgery (SRS) treatments. The aim of this study was to determine the reliability of contour-based volume calculations made by current major SRS platforms. Methods. Spheres ranging in diameter from 6.4 to 38.2 mm were scanned and then delineated on imaging studies. Contour data sets were subsequently exported to 6 SRS treatment-planning platforms for volume calculations and comparisons. This procedure was repeated for the case of a patient with 12 metastatic lesions distributed throughout the brain. Both the phantom and patient datasets were exported to a stand-alone workstation for an independent volume-calculation analysis using a series of 10 algorithms that included approaches such as slice stacking, surface meshing, point-cloud filling, and so forth. Results. Contour data rendered volumes exhibited large variations across the current SRS platforms investigated for both the phantom (-3.6% to 22%) and patient case (1.0%-10.2%). The majority of the clinical SRS systems and algorithms overestimated the volumes of the spheres, compared with their known physical volumes. An independent algorithm analysis found a similar trend in variability, and large variations were typically associated with small objects whose volumes were < 0.4 cm(3) and with those objects located near the end-slice of the scan limits. Conclusions. Significant variations in volume calculation were observed based on data obtained from the SRS systems that were investigated. This observation highlights the need for strict quality assurance and benchmarking efforts when commissioning SRS systems for clinical use and, moreover, when conducting multiinstitutional cross-SRS platform clinical studies. (http://thejns.org/doi/abs/10.3171/2012.7.GKS121016)
引用
收藏
页码:203 / 210
页数:8
相关论文
共 50 条
  • [21] Geometry of contour-based correspondence for stereo
    Zucker, SW
    Li, G
    FIRST INTERNATIONAL SYMPOSIUM ON 3D DATA PROCESSING VISUALIZATION AND TRANSMISSION, 2002, : 709 - 712
  • [22] Contour-based learning for object detection
    Shotton, J
    Blake, A
    Cipolla, R
    TENTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOLS 1 AND 2, PROCEEDINGS, 2005, : 503 - 510
  • [23] Contour-based Optical Proximity Correction
    Zhou, Brian
    Zhu, Liang
    Zhang, Yingchun
    Gu, Yili
    Kang, Xiaohui
    DESIGN FOR MANUFACTURABILITY THROUGH DESIGN-PROCESS INTEGRATION III, 2009, 7275
  • [24] A Contour-Based Feature Extraction Algorithm
    Liua, Wenjiao
    Ralescu, Anca
    ADVANCES IN ARTIFICIAL INTELLIGENCE AND MACHINE LEARNING, 2024, 4 (01): : 2113 - 2127
  • [25] Contour and Enclosed Region Refining for Contour-Based Instance Segmentation
    Gu, Wenchao
    Bai, Shuang
    IEEE TRANSACTIONS ON COGNITIVE AND DEVELOPMENTAL SYSTEMS, 2023, 15 (04) : 2241 - 2253
  • [26] Contour-based object tracking with gradient-based contour attraction field
    Dokladal, P
    Enficiaud, R
    Dejnozkova, E
    2004 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOL III, PROCEEDINGS: IMAGE AND MULTIDIMENSIONAL SIGNAL PROCESSING SPECIAL SESSIONS, 2004, : 17 - 20
  • [27] Contour-Based Large Scale Image Retrieval
    Zhou, Rong
    Zhang, Liqing
    NEURAL INFORMATION PROCESSING, PT III, 2011, 7064 : 565 - 572
  • [28] Contextual inference in contour-based stereo correspondence
    Li, Gang
    Zucker, Steven W.
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 2006, 69 (01) : 59 - 75
  • [29] Contour-based gravity center evaluation of characters
    Kotani, Akio
    Tanemura, Yoshitaka
    Mituyama, Yukio
    Asai, Yoshimi
    Nakamura, Yasuhisa
    Onoye, Takao
    EUROMEDIA '2006, 2006, : 15 - +
  • [30] Evaluation of active contour-based tracking methods
    Zaki, M.
    Youssef, M.
    INTERNATIONAL JOURNAL OF SIGNAL AND IMAGING SYSTEMS ENGINEERING, 2009, 2 (04) : 172 - 182