Reliability of contour-based volume calculation for radiosurgery

被引:11
|
作者
Ma, Lijun [1 ]
Sahgal, Arjun
Nie, Ke [1 ]
Hwang, Andrew [1 ]
Karotki, Aliaksandr [4 ]
Wang, Brian [3 ]
Shrieve, Dennis C. [3 ]
Sneed, Penny K. [1 ]
McDermott, Michael [1 ]
Larson, David A. [1 ,2 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
[2] Washington Fremont Hosp, Gamma Knife Ctr, Fremont, CA USA
[3] Univ Utah, Dept Radiat Oncol, Salt Lake City, UT USA
[4] Univ Toronto, Dept Radiat Oncol, Sunnybrook Odette Canc Ctr, Princess Margaret Hosp, Toronto, ON M5S 1A1, Canada
关键词
volume calculation; volume reconstruction; stereotactic radiosurgery; treatment planning; BRAIN METASTASES; STEREOTACTIC RADIOSURGERY; RADIATION-THERAPY; TUMORS; CONFORMITY; SYSTEM;
D O I
10.3171/2012.7.GKS121016
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Determining accurate target volume is critical for both prescribing and evaluating stereotactic radiosurgery (SRS) treatments. The aim of this study was to determine the reliability of contour-based volume calculations made by current major SRS platforms. Methods. Spheres ranging in diameter from 6.4 to 38.2 mm were scanned and then delineated on imaging studies. Contour data sets were subsequently exported to 6 SRS treatment-planning platforms for volume calculations and comparisons. This procedure was repeated for the case of a patient with 12 metastatic lesions distributed throughout the brain. Both the phantom and patient datasets were exported to a stand-alone workstation for an independent volume-calculation analysis using a series of 10 algorithms that included approaches such as slice stacking, surface meshing, point-cloud filling, and so forth. Results. Contour data rendered volumes exhibited large variations across the current SRS platforms investigated for both the phantom (-3.6% to 22%) and patient case (1.0%-10.2%). The majority of the clinical SRS systems and algorithms overestimated the volumes of the spheres, compared with their known physical volumes. An independent algorithm analysis found a similar trend in variability, and large variations were typically associated with small objects whose volumes were < 0.4 cm(3) and with those objects located near the end-slice of the scan limits. Conclusions. Significant variations in volume calculation were observed based on data obtained from the SRS systems that were investigated. This observation highlights the need for strict quality assurance and benchmarking efforts when commissioning SRS systems for clinical use and, moreover, when conducting multiinstitutional cross-SRS platform clinical studies. (http://thejns.org/doi/abs/10.3171/2012.7.GKS121016)
引用
收藏
页码:203 / 210
页数:8
相关论文
共 50 条
  • [1] Contour-based Interface for Refining Volume Segmentation
    Ijiri, Takashi
    Yokota, Hideo
    COMPUTER GRAPHICS FORUM, 2010, 29 (07) : 2153 - 2160
  • [2] Contour-Based Recognition
    Xu, Yong
    Quan, Yuhui
    Zhang, Zhuming
    Ji, Hui
    Fermueller, Cornelia
    Nishigaki, Morimichi
    Dementhon, Daniel
    2012 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2012, : 3402 - 3409
  • [3] Contour-based warping
    Chan, KH
    Lau, RWH
    GRAPHICAL MODELS AND IMAGE PROCESSING, 1998, 60 (05): : 331 - 348
  • [4] Bilateral Hermite Radial Basis Functions for Contour-based Volume Segmentation
    Ijiri, Takashi
    Yoshizawa, Shin
    Sato, Yu
    Ito, Masaaki
    Yokota, Hideo
    COMPUTER GRAPHICS FORUM, 2013, 32 (02) : 123 - 132
  • [5] Contour-based image representation
    Yamamoto, A
    VIDEO TECHNIQUES AND SOFTWARE FOR FULL-SERVICE NETWORKS, 1997, 2915 : 86 - 95
  • [6] Contour-based Interactive Segmentation
    Popenova, Polina
    Galeev, Danil
    Vorontsova, Anna
    Konushin, Anton
    PROCEEDINGS OF THE THIRTY-SECOND INTERNATIONAL JOINT CONFERENCE ON ARTIFICIAL INTELLIGENCE, IJCAI 2023, 2023, : 1322 - 1330
  • [7] CONTOUR-BASED MOTION ESTIMATION
    DAVIS, LS
    WU, ZQ
    SUN, HF
    COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1983, 23 (03): : 313 - 326
  • [8] Contour-based image retrieval
    Zhang, Zhiyong
    Shi, Zhiping
    Shi, Zhiwei
    Shi, Zhongzhi
    PROCEEDINGS OF THE SIXTH IEEE INTERNATIONAL CONFERENCE ON COGNITIVE INFORMATICS, 2007, : 522 - +
  • [9] CONTOUR-BASED POSITION LINES
    GARCIAFR.J
    JOURNAL OF THE INSTITUTE OF NAVIGATION, 1967, 20 (02): : 146 - &
  • [10] Contour-based image warping
    Chan, KH
    Lau, RWH
    ELECTRONIC IMAGING AND MULTIMEDIA SYSTEMS, 1996, 2898 : 306 - 316