A system for accurate on-line measurement of total gas consumption or production rates in microbioreactors

被引:8
|
作者
van Leeuwen, Michiel [2 ]
Heijnen, Joseph J. [1 ]
Gardeniers, Han [3 ]
Oudshoorn, Arthur [4 ]
Noorman, Henk [5 ]
Visser, Jan [6 ]
van der Wielen, Luuk A. M. [1 ]
van Gulik, Walter M. [1 ]
机构
[1] Delft Univ Technol, Dept Biotechnol, NL-2628 BC Delft, Netherlands
[2] Centocor BV, NL-2333 CD Leiden, Netherlands
[3] Univ Twente, MESA Inst Nanotechnol, NL-7500 AE Enschede, Netherlands
[4] Applikon, NL-3100 AC Schiedam, Netherlands
[5] DSM Antiinfect, NL-2600 AK Delft, Netherlands
[6] Organon, NL-5340 BH Oss, Netherlands
关键词
Microbioreactor; Pressure control; Oxygen consumption; Enzymatic reaction; Oxygen mass transfer; Fermentation; DEEPWELL MICROTITER PLATES; ORBITAL SHAKING; OXYGEN-TRANSFER; CULTURES;
D O I
10.1016/j.ces.2008.09.023
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A system has been developed, based on pressure controlled gas pumping, for accurate measurement of total gas consumption or production rates in the nmol/min range, applicable for on-line monitoring of bioconversions in microbioreactors. The system was validated by carrying out a bioconversion with known stoichiometric relation between gas consumption and substrate conversion, that is, the enzymatic oxidation of glucose to gluconic acid. The reaction was carried out in a stirred microreactor with a working volume of 100 mu L, whereby the oxygen consumption was monitored on-line. Subsequently the system was applied to determine the oxygen transfer capacity of the microbioreactor. The dissolved oxygen concentration was measured with an optical dissolved oxygen sensor, which was integrated near the bottom of the reactor. Different stirrer sizes and geometries were investigated for their effect on the mass transfer of oxygen. A maximal k(L)a of 156 +/- 10 h(-1), allowing a maximal O-2-transfer rate up to 50 mmol O-2/L/h, was reached which is sufficient to grow cells aerobically in (fed-)batch mode at relatively high biomass concentrations. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:455 / 458
页数:4
相关论文
共 50 条
  • [41] On-line measurement and monitoring system based on digital image processing technology on granule in gas flue
    Cheng, LJ
    Mu, PG
    Dai, SG
    Zheng, ZH
    ICEMI'2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOLS 1-3, 2003, : 2055 - 2059
  • [42] On-line measurement of N2O in flue gas
    Eisenberger, HJ
    Fabinski, W
    Hielscher, B
    Zochbauer, M
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 1998, 58 (06): : 225 - 231
  • [43] On-line measurement of N2O in flue gas
    Andres, B
    Fabinski, W
    Hielscher, B
    Zöchbauer, M
    Brandl, A
    Eisenberger, HJ
    RECENT DEVELOPMENTS IN MEASUREMENT AND ASSESSMENT OF AIR POLLUTION, 1999, 1443 : 471 - 480
  • [44] On-line gas hold-up measurement in flotation columns
    Pérez-Garibay, R
    De Villar, R
    CANADIAN METALLURGICAL QUARTERLY, 1999, 38 (02) : 141 - 148
  • [45] Novel Optical Fiber Gas Sensor for On-line Measurement of Methane
    WANG Shu-tao~1
    2.College of Electr.Eng.
    Semiconductor Photonics and Technology, 2004, (02) : 141 - 144
  • [46] Fast and Accurate On-line Prediction of Performance and Power Consumption in Multicore-based Systems
    Lee, Young-Ho
    Kim, Jihong
    2013 12TH IEEE INTERNATIONAL CONFERENCE ON TRUST, SECURITY AND PRIVACY IN COMPUTING AND COMMUNICATIONS (TRUSTCOM 2013), 2013, : 1879 - 1886
  • [47] On-line measurement system for monitoring ring tool misalignments
    Xie, T
    Greivenkamp, JE
    OPTICAL MANUFACTURING AND TESTING II, 1997, 3134 : 494 - 503
  • [48] On-line measurement system of GaAs photocathodes and its applications
    Zou Jijun
    Feng Lin
    Lin Gangyong
    Rao Yuntao
    Yang Zhi
    Qian Yunsheng
    Chang Benkang
    OPTOELECTRONIC MATERIALS AND DEVICES II, 2007, 6782
  • [49] Laser profiling system for on-line measurement of superfine surfaces
    Zhou, Zhao-Fei
    Zhang, Tao
    Zhou, Wei-Dong
    Applied Optics, 2002, 41 (01): : 125 - 129