A system for accurate on-line measurement of total gas consumption or production rates in microbioreactors

被引:8
|
作者
van Leeuwen, Michiel [2 ]
Heijnen, Joseph J. [1 ]
Gardeniers, Han [3 ]
Oudshoorn, Arthur [4 ]
Noorman, Henk [5 ]
Visser, Jan [6 ]
van der Wielen, Luuk A. M. [1 ]
van Gulik, Walter M. [1 ]
机构
[1] Delft Univ Technol, Dept Biotechnol, NL-2628 BC Delft, Netherlands
[2] Centocor BV, NL-2333 CD Leiden, Netherlands
[3] Univ Twente, MESA Inst Nanotechnol, NL-7500 AE Enschede, Netherlands
[4] Applikon, NL-3100 AC Schiedam, Netherlands
[5] DSM Antiinfect, NL-2600 AK Delft, Netherlands
[6] Organon, NL-5340 BH Oss, Netherlands
关键词
Microbioreactor; Pressure control; Oxygen consumption; Enzymatic reaction; Oxygen mass transfer; Fermentation; DEEPWELL MICROTITER PLATES; ORBITAL SHAKING; OXYGEN-TRANSFER; CULTURES;
D O I
10.1016/j.ces.2008.09.023
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A system has been developed, based on pressure controlled gas pumping, for accurate measurement of total gas consumption or production rates in the nmol/min range, applicable for on-line monitoring of bioconversions in microbioreactors. The system was validated by carrying out a bioconversion with known stoichiometric relation between gas consumption and substrate conversion, that is, the enzymatic oxidation of glucose to gluconic acid. The reaction was carried out in a stirred microreactor with a working volume of 100 mu L, whereby the oxygen consumption was monitored on-line. Subsequently the system was applied to determine the oxygen transfer capacity of the microbioreactor. The dissolved oxygen concentration was measured with an optical dissolved oxygen sensor, which was integrated near the bottom of the reactor. Different stirrer sizes and geometries were investigated for their effect on the mass transfer of oxygen. A maximal k(L)a of 156 +/- 10 h(-1), allowing a maximal O-2-transfer rate up to 50 mmol O-2/L/h, was reached which is sufficient to grow cells aerobically in (fed-)batch mode at relatively high biomass concentrations. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:455 / 458
页数:4
相关论文
共 50 条
  • [31] Development of On-Line Measurement System for Adsorption Process
    Kim, Byoung Chul
    Lee, Ki Sung
    Yamamoto, Takuji
    Kim, Young Han
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2009, 47 (03): : 321 - 326
  • [32] On-line dimension measurement system for opaque cylinder
    Wang, Zhenhai
    Wang, Yukun
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 1998, 9 (03): : 238 - 240
  • [33] A Novel On-line Alumina Concentration Measurement System
    Zhang, Sen
    Yang, Qiang
    Yin, Yixin
    Cao, Bin
    2015 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2015, : 362 - 368
  • [34] Continuous on-line measurement of washing efficiency in production-line washing
    Kurz, J
    Klein, P
    Scheinecker, D
    TEKSTIL, 1998, 47 (05): : 272 - 273
  • [35] The 'Inmarsis system': On-line petroleum and gas equipment
    Anon
    Gazovaya Promyshlennost, 2001, (01): : 8 - 10
  • [36] Low-cost system for on-line measurement of plant transpiration and photosynthesis in greenhouse production
    Schmidt, U
    SECOND INTERNATIONAL SYMPOSIUM ON SENSORS IN HORTICULTURE, 1998, (421): : 249 - 257
  • [37] SYSTEM FOR ACCURATE ON-LINE CALIBRATION OF MULTIPLE UNIT POTENTIAL RECORDING
    IRWIN, DA
    CRISWELL, HE
    PHYSIOLOGY & BEHAVIOR, 1974, 12 (04) : 703 - 705
  • [39] TOPS (TOTAL ON-LINE PRODUCTION CONTROL-SYSTEM) AT SUMITOMO-METAL-INDUSTRIES, LTD
    MIYAJIMA, R
    TOYODA, T
    SUMITOMO SEARCH, 1972, (08): : 81 - 92
  • [40] Digital measurement system for generator on-line PD monitoring system
    Du, L
    Sun, CX
    Liao, RJ
    Li, J
    Zhou, Q
    ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, 2001, : 322 - 325