High resolution navigated three-dimensional T1-weighted hepatobiliary MRI using gadoxetic acid optimized for 1.5 tesla

被引:48
|
作者
Nagle, Scott K. [1 ,2 ]
Busse, Reed F. [3 ]
Brau, Anja C. [4 ]
Brittain, Jean H. [3 ]
Frydrychowicz, Alex [5 ]
Iwadate, Yuji [6 ]
Reeder, Scott B. [1 ,2 ,7 ,8 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53792 USA
[3] GE Healthcare, Global Appl Sci Lab, Madison, WI USA
[4] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[5] Med Univ Lubeck, Dept Radiol, D-23538 Lubeck, Germany
[6] GE Healthcare Japan, Global Appl Sci Lab, Hino, Tokyo, Japan
[7] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53792 USA
[8] Univ Wisconsin, Dept Med, Madison, WI 53792 USA
关键词
magnetic resonance; liver imaging; navigator; gadoxetic acid; optimization; primary sclerosing cholangitis; GD-EOB-DTPA; FOCAL NODULAR HYPERPLASIA; BREATH-HOLD EXAMINATION; GADOBENATE DIMEGLUMINE; CONTRAST AGENT; CLINICAL-EVALUATION; INITIAL-EXPERIENCE; LIVER; PHASE; BILIARY;
D O I
10.1002/jmri.23713
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine optimal delay times and flip angles for T1-weighted hepatobiliary imaging at 1.5 Tesla (T) with gadoxetic acid and to demonstrate the feasibility of using a high-resolution navigated optimized T1-weighted pulse sequence to evaluate biliary disease. Materials and Methods: Eight healthy volunteers were scanned at 1.5T using a T1-weighted three-dimensional (3D)-SPGR pulse sequence following the administration of 0.05 mmol/kg of gadoxetic acid. Navigator-gating enabled acquisition of high spatial resolution (1.2 X 1.4 X 1.8 mm3, interpolated to 0.7 X 0.7 X 0.9 mm3) images in approximately 5 min of free-breathing. Multiple breath-held acquisitions were performed at flip angles between 15 degrees and 45 degrees to optimize T1 weighting. To evaluate the performance of this optimized sequence in the setting of biliary disease, the image quality and biliary excretion of 51 consecutive clinical scans performed to assess primary sclerosing cholangitis (PSC) were evaluated. Results: Optimal hepatobiliary imaging occurs at 1525 min, using a 40 degrees flip angle. The image quality and visualization of biliary excretion in the PSC scans were excellent, despite the decreased liver function in some patients. Visualization of reduced excretion often provided diagnostic information that was unavailable by conventional magnetic resonance cholangiopancreatography (MRCP). Conclusion: High-resolution navigated 3D-SPGR hepatobiliary imaging using gadoxetic acid and optimized scan parameters is technically feasible and can be clinically useful, even in patients with decreased hepatobiliary function. J. Magn. Reson. Imaging 2012;36:890899. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:890 / 899
页数:10
相关论文
共 50 条
  • [41] Digital three-dimensional atlas of quail development using high-resolution MRI
    Ruffins, Seth W.
    Martin, Melanie
    Keough, Lindsey
    Truong, Salina
    Fraser, Scott E.
    Jacobs, Russell E.
    Lansford, Rusty
    THESCIENTIFICWORLDJOURNAL, 2007, 7 : 592 - 604
  • [42] An approach for three-dimensional visualization using high-resolution MRI of the temporomandibular joint
    Hayakawa, Y.
    Kober, C.
    Otonan-Yamamoto, M.
    Otonari, T.
    Wakoh, M.
    Sano, T.
    DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (06) : 341 - 347
  • [43] Hepatocellular carcinoma detection: diagnostic performance of a simulated abbreviated MRI protocol combining diffusion-weighted and T1-weighted imaging at the delayed phase post gadoxetic acid
    Cecilia Besa
    Sara Lewis
    Pari V. Pandharipande
    Jagpreet Chhatwal
    Amita Kamath
    Nancy Cooper
    Ashley Knight-Greenfield
    James S. Babb
    Paolo Boffetta
    Norma Padron
    Claude B. Sirlin
    Bachir Taouli
    Abdominal Radiology, 2017, 42 : 179 - 190
  • [44] Hepatocellular carcinoma detection: diagnostic performance of a simulated abbreviated MRI protocol combining diffusion-weighted and T1-weighted imaging at the delayed phase post gadoxetic acid
    Besa, Cecilia
    Lewis, Sara
    Pandharipande, Pari V.
    Chhatwal, Jagpreet
    Kamath, Amita
    Cooper, Nancy
    Knight-Greenfield, Ashley
    Babb, James S.
    Boffetta, Paolo
    Padron, Norma
    Sirlin, Claude B.
    Taouli, Bachir
    ABDOMINAL RADIOLOGY, 2017, 42 (01) : 179 - 190
  • [45] Contrast Agent-Induced High Signal Intensity in Dentate Nucleus on Unenhanced T1-Weighted Images Comparison of Gadodiamide and Gadoxetic Acid
    Ichikawa, Shintaro
    Motosugi, Utaroh
    Omiya, Yoshie
    Onishi, Hiroshi
    INVESTIGATIVE RADIOLOGY, 2017, 52 (07) : 389 - 395
  • [46] High-resolution diffusion MRI at 7T using a three-dimensional multi-slab acquisition
    Wu, Wenchuan
    Poser, Benedikt A.
    Douaud, Gwenaelle
    Frost, Robert
    In, Myung-Ho
    Speck, Oliver
    Koopmans, Peter J.
    Miller, Karla L.
    NEUROIMAGE, 2016, 143 : 1 - 14
  • [47] High resolution three dimensional intracranial arterial wall imaging at 3 T using T1 weighted SPACE
    Zhang, Lei
    Zhang, Na
    Wu, Jun
    Zhang, Lijuan
    Huang, Yanyan
    Liu, Xin
    Chung, Yiu-Cho
    MAGNETIC RESONANCE IMAGING, 2015, 33 (09) : 1026 - 1034
  • [48] High-resolution, three-dimensional diffusion-weighted breast imaging using DESS
    Granlund, Kristin L.
    Staroswiecki, Ernesto
    Alley, Marcus T.
    Daniel, Bruce L.
    Hargreaves, Brian A.
    MAGNETIC RESONANCE IMAGING, 2014, 32 (04) : 330 - 341
  • [49] Heavy T1-weighted three-dimensional magnetic resonance imaging has a potential to visualize unstable carotid atheroma
    Yamada, N
    Otsubo, R
    Higashi, M
    Tanaka, R
    Nagano, K
    Sakuma, T
    Minematsu, K
    Naritomi, H
    Naito, H
    STROKE, 2004, 35 (01) : 262 - 262
  • [50] Can Three-Dimensional T1-weighted MR Imaging Visualize the Vascular Lumen after Carotid Artery Stenting?
    Kiriki, Masato
    Takatsu, Yasuo
    Miyati, Tosiaki
    Kotoura, Noriko
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2024,