High resolution navigated three-dimensional T1-weighted hepatobiliary MRI using gadoxetic acid optimized for 1.5 tesla

被引:48
|
作者
Nagle, Scott K. [1 ,2 ]
Busse, Reed F. [3 ]
Brau, Anja C. [4 ]
Brittain, Jean H. [3 ]
Frydrychowicz, Alex [5 ]
Iwadate, Yuji [6 ]
Reeder, Scott B. [1 ,2 ,7 ,8 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53792 USA
[3] GE Healthcare, Global Appl Sci Lab, Madison, WI USA
[4] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[5] Med Univ Lubeck, Dept Radiol, D-23538 Lubeck, Germany
[6] GE Healthcare Japan, Global Appl Sci Lab, Hino, Tokyo, Japan
[7] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53792 USA
[8] Univ Wisconsin, Dept Med, Madison, WI 53792 USA
关键词
magnetic resonance; liver imaging; navigator; gadoxetic acid; optimization; primary sclerosing cholangitis; GD-EOB-DTPA; FOCAL NODULAR HYPERPLASIA; BREATH-HOLD EXAMINATION; GADOBENATE DIMEGLUMINE; CONTRAST AGENT; CLINICAL-EVALUATION; INITIAL-EXPERIENCE; LIVER; PHASE; BILIARY;
D O I
10.1002/jmri.23713
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine optimal delay times and flip angles for T1-weighted hepatobiliary imaging at 1.5 Tesla (T) with gadoxetic acid and to demonstrate the feasibility of using a high-resolution navigated optimized T1-weighted pulse sequence to evaluate biliary disease. Materials and Methods: Eight healthy volunteers were scanned at 1.5T using a T1-weighted three-dimensional (3D)-SPGR pulse sequence following the administration of 0.05 mmol/kg of gadoxetic acid. Navigator-gating enabled acquisition of high spatial resolution (1.2 X 1.4 X 1.8 mm3, interpolated to 0.7 X 0.7 X 0.9 mm3) images in approximately 5 min of free-breathing. Multiple breath-held acquisitions were performed at flip angles between 15 degrees and 45 degrees to optimize T1 weighting. To evaluate the performance of this optimized sequence in the setting of biliary disease, the image quality and biliary excretion of 51 consecutive clinical scans performed to assess primary sclerosing cholangitis (PSC) were evaluated. Results: Optimal hepatobiliary imaging occurs at 1525 min, using a 40 degrees flip angle. The image quality and visualization of biliary excretion in the PSC scans were excellent, despite the decreased liver function in some patients. Visualization of reduced excretion often provided diagnostic information that was unavailable by conventional magnetic resonance cholangiopancreatography (MRCP). Conclusion: High-resolution navigated 3D-SPGR hepatobiliary imaging using gadoxetic acid and optimized scan parameters is technically feasible and can be clinically useful, even in patients with decreased hepatobiliary function. J. Magn. Reson. Imaging 2012;36:890899. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:890 / 899
页数:10
相关论文
共 50 条
  • [31] Contrast behavior of high-spatial-resolution T1-weighted MR imaging at 3.0 T vs. 1.5 T
    Isoda, Hiroyoshi
    Arizono, Shigeki
    Shimada, Kotaro
    Hirokawa, Yuusuke
    Maetani, Yoji S.
    Kataoka, Masako
    Nakamoto, Yuji
    Shibata, Toshiya
    Togashi, Kaori
    CLINICAL IMAGING, 2011, 35 (02) : 133 - 138
  • [32] Three-dimensional, T1-weighted gradient-echo imaging of the brain with a volumetric interpolated examination
    Wetzel, SG
    Johnson, G
    Tan, AGS
    Cha, SM
    Knopp, EA
    Lee, VS
    Thomasson, D
    Rofsky, NM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (06) : 995 - 1002
  • [33] T1-weighted three-dimensional magnetization transfer MR of the brain: Improved lesion contrast enhancement
    Finelli, DA
    Hurst, GC
    Gullapalli, RP
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (01) : 59 - 64
  • [34] T1-weighted imaging of the brain at 3 tesla using a 2-dimensional spoiled gradient echo technique
    Runge, VM
    Patel, MC
    Baumann, SS
    Simonetta, AB
    Ponzo, JA
    Lesley, WS
    Calderwood, GW
    Naul, LG
    INVESTIGATIVE RADIOLOGY, 2006, 41 (02) : 68 - 75
  • [35] Three-dimensional digital mouse atlas using high-resolution MRI
    Dhenain, M
    Ruffins, SW
    Jacobs, RE
    DEVELOPMENTAL BIOLOGY, 2001, 232 (02) : 458 - 470
  • [36] High-resolution T1-weighted gradient echo imaging for liver MRI using parallel imaging at high-acceleration factors
    Jeong Hee Yoon
    Jeong Min Lee
    Mi Hye Yu
    Eun Ju Kim
    Joon Koo Han
    Byung Ihn Choi
    Abdominal Imaging, 2014, 39 : 711 - 721
  • [37] Age-Related Changes of the Human Crystalline Lens on High-Spatial Resolution Three-Dimensional T1-Weighted Brain Magnetic Resonance Images In Vivo
    Streckenbach, Felix
    Stachs, Oliver
    Langner, Sonke
    Guthoff, Rudolf F.
    Meinel, Felix G.
    Weber, Marc-Andre
    Stahnke, Thomas
    Beller, Ebba
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (14)
  • [38] High-resolution T1-weighted gradient echo imaging for liver MRI using parallel imaging at high-acceleration factors
    Yoon, Jeong Hee
    Lee, Jeong Min
    Yu, Mi Hye
    Kim, Eun Ju
    Han, Joon Koo
    Choi, Byung Ihn
    ABDOMINAL IMAGING, 2014, 39 (04): : 711 - 721
  • [39] Increased spatial resolution using a three-dimensional T1-weighted gradient-echo MR sequence results in greater hypointense lesion volumes in multiple sclerosis
    Filippi, M
    Rocca, MA
    Horsfield, MA
    Rovaris, M
    Pereira, C
    Yousry, TA
    Colombo, B
    Comi, G
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (02) : 235 - 238
  • [40] Better continuity of the facial nerve demonstrated in the temporal bone on three-dimensional T1-weighted imaging with volume isotropic turbo spin echo acquisition than that with fast field echo at 3.0 tesla MRI
    Haneda, Jun
    Ishikawa, Kazuhiro
    Okamoto, Kouichirou
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2019, 63 (06) : 745 - 750