CLINICAL GAIT ANALYSIS OF SUBJECTS WITH TRANS-FEMORAL AMPUTATION USING POLYCENTRIC FOUR-BAR LINKAGE PROSTHETIC KNEE JOINT

被引:8
|
作者
Mohanty, Rajesh Kumar [1 ,2 ]
Biswal, Sthirpranjyan [1 ]
Sahoo, Pabitra Kumar [3 ]
Das, Sakti Prasad [3 ]
Mohanty, R. C. [1 ]
Sabut, Sukanta Kumar [4 ]
机构
[1] Centurion Univ Technol & Management, Dept Mech Engn, R Sitapur, Odisha, India
[2] Swami Vivekanand Natl Inst Rehabil Training & Res, Dept Prosthet & Orthot, Cuttack, Odisha, India
[3] Swami Vivekanand Natl Inst Rehabil Training & Res, Dept Phys Med & Rehabil, Cuttack, Odisha, India
[4] Kalinga Inst Ind Technol, Sch Elect Engn, Bhubaneswar, Odisha, India
关键词
Amputation; four-bar; gait analysis; knee; polycentric; prosthetic; AMPUTEE PATIENTS; PERFORMANCE; WALKING; BALANCE;
D O I
10.1142/S0219519420500219
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Background: Adequate research is not reported so far to underline the influence of commonly used polycentric knee joints on gait performance of subjects with trans-femoral amputation. Objective: The intent of this investigation is to analyze prosthetic gait of unilateral traumatic trans-femoral amputees with polycentric four-bar linkage knee and compare it with normal subjects for evaluating any asymmetry in gait performance. Methods: Objective three-dimensional gait analysis of 15 subjects [mean (age): 36.4 (10.7) years] were performed in gait lab through force plate and optoelectronic devices to measure temporal-spatial parameters, kinematic and kinetic performances. Gait patterns of amputees were compared with those of 15 individuals with normal gait to analyze distinct functionalities of existing polycentric knee. Results: Asymmetry in gait was observed between amputees and normal subjects for all variables concerned (p < 0.05). Amputee gait was with significantly lesser velocity, cadence with shorter step and stride length. There was significantly less hip, knee and pelvic motions, however, pelvic obliquity and rotation did not show significant difference from the normal subjects. The vertical component of the ground reaction force differed significantly between prosthetic and intact limb [49.7 (8.5)% and 90.4 (7.4)% body weight] and also from normal subjects [107.5 (2.4)% body weight] during stance (p < 0.05). Interpretation and Conclusion. This difference may be attributed to nonproportionate loading of limbs and mechanical adaptations for counteracting deficiencies of prosthetic side. This study will help to explain gait asymmetry in trans-femoral amputees and to identify underlying mechanisms to enhance the quality of the existing design of prosthetic knee through optimizing design parameters and utilizing appropriate materials.
引用
收藏
页数:13
相关论文
共 29 条
  • [1] FATIGUE ANALYSIS OF POLYCENTRIC PROSTHETIC KNEE FOR TRANS-FEMORAL AMPUTATION
    Mohanty, Rajesh Kumar
    Mohanty, Ramesh Chandra
    Sabut, Sukanta Kumar
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2023, 23 (01)
  • [2] KINETOSTATIC ANALYSIS FOR FOUR-BAR LINKAGE MECHANISM OF PROSTHETIC KNEE JOINT
    Liu, Xuhui
    Guo, Tiantian
    Zhang, Jiahao
    Yang, Guang
    Sun, Luchan
    Luo, Qiwen
    Qiu, Ye
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2019, 19 (04)
  • [3] Development of four-bar polycentric knee joint with stance-phase knee flexion
    Santiphap Phoengsongkhro
    Pairat Tangpornprasert
    Pattarapol Yotnuengnit
    Manunchaya Samala
    Chanyaphan Virulsri
    Scientific Reports, 13
  • [4] Development of four-bar polycentric knee joint with stance-phase knee flexion
    Phoengsongkhro, Santiphap
    Tangpornprasert, Pairat
    Yotnuengnit, Pattarapol
    Samala, Manunchaya
    Virulsri, Chanyaphan
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [5] Optimising the trans-femoral prosthetic alignment for running, by lowering the knee joint
    Burkett, B
    Smeathers, J
    Barker, T
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2001, 25 (03) : 210 - 219
  • [6] Trajectory tracking control of a four-bar linkage prosthetic knee with magnetorheological damper
    Zhang, Jiawei
    Hu, Guoliang
    Zhao, Jinpeng
    Zhu, Wencai
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2024, 610
  • [7] Gait Motion Analysis in the Unrestrained Condition of Trans-Femoral Amputee with a Prosthetic Limb
    Hayashi, Yuichiro
    Tsujiuchi, Nobutaka
    Koizumi, Takayuki
    Uno, Ryuji
    Matsuda, Yasushi
    Tsuchiya, Youtaro
    Inoue, Yoshio
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 3040 - 3043
  • [8] FEM-based fatigue analysis on a four-bar polycentric knee of above-knee prostheses
    Noorani, Mohammad-Reza Sayyed
    Hoseini, Saman
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2024, 44 (02) : 120 - 132
  • [9] Biomechanical Kinetic Consideration of the Unrestrained Trans-Femoral Prosthetic Gait Using Energy Consumption
    Hayashi, Yuichiro
    Tsujiuchi, Nobutaka
    Koizumi, Takayuki
    Makino, Yuta
    Matsuda, Yasushi
    Tsuchiya, Youtaro
    Inoue, Yoshio
    2013 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2013, : 2278 - 2283
  • [10] Effects of a hydraulic knee joint on energy consumption, gait and patient satisfaction in trans-femoral amputees
    Ulger, Ozlem
    Topuz, Semra
    Bayramlar, Kezban
    TURKISH JOURNAL OF PHYSIOTHERAPY REHABILITATION-FIZYOTERAPI REHABILITASYON, 2009, 20 (03): : 169 - 177