CLINICAL GAIT ANALYSIS OF SUBJECTS WITH TRANS-FEMORAL AMPUTATION USING POLYCENTRIC FOUR-BAR LINKAGE PROSTHETIC KNEE JOINT

被引:8
|
作者
Mohanty, Rajesh Kumar [1 ,2 ]
Biswal, Sthirpranjyan [1 ]
Sahoo, Pabitra Kumar [3 ]
Das, Sakti Prasad [3 ]
Mohanty, R. C. [1 ]
Sabut, Sukanta Kumar [4 ]
机构
[1] Centurion Univ Technol & Management, Dept Mech Engn, R Sitapur, Odisha, India
[2] Swami Vivekanand Natl Inst Rehabil Training & Res, Dept Prosthet & Orthot, Cuttack, Odisha, India
[3] Swami Vivekanand Natl Inst Rehabil Training & Res, Dept Phys Med & Rehabil, Cuttack, Odisha, India
[4] Kalinga Inst Ind Technol, Sch Elect Engn, Bhubaneswar, Odisha, India
关键词
Amputation; four-bar; gait analysis; knee; polycentric; prosthetic; AMPUTEE PATIENTS; PERFORMANCE; WALKING; BALANCE;
D O I
10.1142/S0219519420500219
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Background: Adequate research is not reported so far to underline the influence of commonly used polycentric knee joints on gait performance of subjects with trans-femoral amputation. Objective: The intent of this investigation is to analyze prosthetic gait of unilateral traumatic trans-femoral amputees with polycentric four-bar linkage knee and compare it with normal subjects for evaluating any asymmetry in gait performance. Methods: Objective three-dimensional gait analysis of 15 subjects [mean (age): 36.4 (10.7) years] were performed in gait lab through force plate and optoelectronic devices to measure temporal-spatial parameters, kinematic and kinetic performances. Gait patterns of amputees were compared with those of 15 individuals with normal gait to analyze distinct functionalities of existing polycentric knee. Results: Asymmetry in gait was observed between amputees and normal subjects for all variables concerned (p < 0.05). Amputee gait was with significantly lesser velocity, cadence with shorter step and stride length. There was significantly less hip, knee and pelvic motions, however, pelvic obliquity and rotation did not show significant difference from the normal subjects. The vertical component of the ground reaction force differed significantly between prosthetic and intact limb [49.7 (8.5)% and 90.4 (7.4)% body weight] and also from normal subjects [107.5 (2.4)% body weight] during stance (p < 0.05). Interpretation and Conclusion. This difference may be attributed to nonproportionate loading of limbs and mechanical adaptations for counteracting deficiencies of prosthetic side. This study will help to explain gait asymmetry in trans-femoral amputees and to identify underlying mechanisms to enhance the quality of the existing design of prosthetic knee through optimizing design parameters and utilizing appropriate materials.
引用
收藏
页数:13
相关论文
共 29 条
  • [11] On the application of spatial four-bar motion and axode generation for the design of a prosthetic canine knee joint
    Russell, Kevin
    Chung, Cheng-Shu
    Lin, Lee-Shuan
    Chen, Chien-Hsing
    Lee, Wen-Tzong
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2024, 238 (10) : 4418 - 4426
  • [12] A novel four-bar linkage prosthetic knee based on magnetorheological effect: principle, structure, simulation and control
    Xu, Lei
    Wang, Dai-Hua
    Fu, Qiang
    Yuan, Gang
    Hu, Lei-Zi
    SMART MATERIALS AND STRUCTURES, 2016, 25 (11)
  • [13] Study and evaluation of four bar polycentric knee used in the prosthetic limb for transfemoral amputee during the gait cycle
    Al-Maliky, Firas Thair
    Chiad, Jumaa Salman
    MATERIALS TODAY-PROCEEDINGS, 2021, 42 : 2706 - 2712
  • [14] Dynamic Behavior Analysis of a Planar Four-bar Linkage with Multiple Clearances Joint
    Varedi, S. M.
    Daniali, H. M.
    Dardel, M.
    Fathi, A.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2015, 28 (02): : 243 - 250
  • [15] A method for optimal synthesis of a biomimetic four-bar linkage knee joint for a knee-ankle-foot orthosis
    Bapat G.M.
    Sujatha S.
    1600, Trans Tech Publications Ltd (32): : 20 - 28
  • [16] Unrestrained human gait motion analysis of healthy subjects and trans-femoral amputee using mobile force plate
    Hayashi, Yuichiro
    Tsujiuchi, Nobutaka
    Koizumi, Takayuki
    Matsuda, Yasushi
    Tsuchiya, Youtaro
    Inoue, Yoshio
    Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, 2013, 79 (805): : 3059 - 3074
  • [17] Unrestrained Kinetic Analysis of Trans-Femoral Prosthetic Gait Using Wearable Six-Axis Force/Moment Sensor
    Hayashi, Yuichiro
    Tsujiuchi, Nobutaka
    Koizumi, Takayuki
    Matsuda, Yasushi
    Tsuchiya, Youtaro
    2013 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2013, : 2284 - 2289
  • [18] Design and optimization of exoskeleton structure of lower limb knee joint based on cross four-bar linkage
    Gao, Moyao
    Wang, Zhanli
    Li, Shuang
    Li, Jing
    Pang, Zaixiang
    Liu, Shuai
    Duan, Zhifeng
    AIP ADVANCES, 2021, 11 (06)
  • [19] 3D Printed Robot Hand Structure Using Four-Bar Linkage Mechanism for Prosthetic Application
    Wahit, Mohamad Aizat Abdul
    Ahmad, Siti Anom
    Marhaban, Mohammad Hamiruce
    Wada, Chikamune
    Izhar, Lila Iznita
    SENSORS, 2020, 20 (15) : 1 - 22
  • [20] Optimal free-defect synthesis of four-bar linkage with joint clearance using PSO algorithm
    Arash Sardashti
    H. M. Daniali
    S. M. Varedi
    Meccanica, 2013, 48 : 1681 - 1693