Development of four-bar polycentric knee joint with stance-phase knee flexion

被引:2
|
作者
Phoengsongkhro, Santiphap [1 ,2 ,3 ]
Tangpornprasert, Pairat [1 ,2 ,3 ]
Yotnuengnit, Pattarapol [4 ]
Samala, Manunchaya [5 ]
Virulsri, Chanyaphan [1 ,2 ,3 ]
机构
[1] Chulalongkorn Univ, Ctr Excellence Prosthet & Orthoped Implant, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Fac Engn, Dept Mech Engn, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Fac Engn, Biomed Engn Res Ctr, Bangkok 10330, Thailand
[4] Chulalongkorn Univ, Fac Med, Dept Rehabil Med, Bangkok 10330, Thailand
[5] Mahidol Univ, Fac Med, Siriraj Hosp, Sirindhorn Sch Prosthet & Orthot, Bangkok 10700, Thailand
关键词
DESIGN; PRESCRIPTION; PERFORMANCE; MECHANISMS; GAIT;
D O I
10.1038/s41598-023-49879-4
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A conventional 4-bar polycentric knee and solid ankle cushion heel foot (SACH foot) have been commonly used in developing countries. However, they cannot perform stance-phase knee flexion, which makes a person with an amputation walk unnaturally and with less stability. This research proposes a novel design of a 4-bar polycentric knee with stance-phase knee flexion ability (4BSF), which can perform both stance and swing-phase knee flexion, like able-bodied gait. In the proposed conceptual design, the instantaneous center of rotation (ICR) path is repositioned during the stance phase. The ICR was placed in front of the ground reaction force (GRF) to initiate knee flexion during the loading response. The prototype was validated by a single-subject pilot study at the Gait analysis laboratory. The results showed that a person with an amputation walks with stance-phase knee flexion using the proposed 4BSF. The maximum knee flexion angle is more than 10 degrees during the stance phase. Furthermore, when the 4BSF was used with a SACH foot, the amount of time to achieve the foot flat was shorter, and the foot flat duration time was twice as long as the conventional 4-bar polycentric knee.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Development of four-bar polycentric knee joint with stance-phase knee flexion
    Santiphap Phoengsongkhro
    Pairat Tangpornprasert
    Pattarapol Yotnuengnit
    Manunchaya Samala
    Chanyaphan Virulsri
    Scientific Reports, 13
  • [2] COMPLIANCE FOR A CROSS FOUR-BAR KNEE JOINT
    Hamon, A.
    Aoustin, Y.
    FIELD ROBOTICS, 2012, : 750 - 757
  • [3] Lower limb prosthesis: Optimization by lattice and four-bar polycentric knee
    Contreras-Tenorio, Enrique
    Kardasch-Nava, Ilse
    Gonzalez de Salceda, Shazer
    Fuentes-Alvarez, Ruben
    Beltran Fernandez, Juan Alfonso
    Rincon-Martinez, Karla
    Alfaro-Ponce, Mariel
    Matehuala-Moran, Ivan
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 4801 - 4807
  • [4] FEM-based fatigue analysis on a four-bar polycentric knee of above-knee prostheses
    Noorani, Mohammad-Reza Sayyed
    Hoseini, Saman
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2024, 44 (02) : 120 - 132
  • [5] The influence of stance-phase knee flexion on the vertical displacement of the trunk during normal walking
    Gard, SA
    Childress, DS
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (01): : 26 - 32
  • [6] Biomechanical and Clinical Correlates of Stance-Phase Knee Flexion in Persons With Spastic Cerebral Palsy
    Rha, Dong-Wook
    Cahill-Rowley, Katelyn
    Young, Jeffrey
    Torburn, Leslie
    Stephenson, Katherine
    Rose, Jessica
    PM&R, 2016, 8 (01) : 11 - 18
  • [7] Synthesis of a four-bar knee mechanism generating a compatible motion to the knee joint movements
    Chang, Liang-Wey
    Li, Chin-Cheng
    Shaw, Dein
    Biomedical Engineering - Applications, Basis and Communications, 1996, 8 (05): : 441 - 446
  • [8] Design and quantitative evaluation of a stance-phase controlled prosthetic knee joint for children
    Andrysek, J
    Naumann, S
    Cleghorn, WL
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2005, 13 (04) : 437 - 443
  • [9] A four-bar knee joint measurement walking system for prosthesis design
    Zhang, Yibin
    Cao, Wujing
    Yu, Hongliu
    Meng, Qiaoling
    Lv, Jie
    TECHNOLOGY AND HEALTH CARE, 2021, 29 (04) : 823 - 828
  • [10] KINETOSTATIC ANALYSIS FOR FOUR-BAR LINKAGE MECHANISM OF PROSTHETIC KNEE JOINT
    Liu, Xuhui
    Guo, Tiantian
    Zhang, Jiahao
    Yang, Guang
    Sun, Luchan
    Luo, Qiwen
    Qiu, Ye
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2019, 19 (04)