Development of four-bar polycentric knee joint with stance-phase knee flexion

被引:2
|
作者
Phoengsongkhro, Santiphap [1 ,2 ,3 ]
Tangpornprasert, Pairat [1 ,2 ,3 ]
Yotnuengnit, Pattarapol [4 ]
Samala, Manunchaya [5 ]
Virulsri, Chanyaphan [1 ,2 ,3 ]
机构
[1] Chulalongkorn Univ, Ctr Excellence Prosthet & Orthoped Implant, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Fac Engn, Dept Mech Engn, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Fac Engn, Biomed Engn Res Ctr, Bangkok 10330, Thailand
[4] Chulalongkorn Univ, Fac Med, Dept Rehabil Med, Bangkok 10330, Thailand
[5] Mahidol Univ, Fac Med, Siriraj Hosp, Sirindhorn Sch Prosthet & Orthot, Bangkok 10700, Thailand
关键词
DESIGN; PRESCRIPTION; PERFORMANCE; MECHANISMS; GAIT;
D O I
10.1038/s41598-023-49879-4
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A conventional 4-bar polycentric knee and solid ankle cushion heel foot (SACH foot) have been commonly used in developing countries. However, they cannot perform stance-phase knee flexion, which makes a person with an amputation walk unnaturally and with less stability. This research proposes a novel design of a 4-bar polycentric knee with stance-phase knee flexion ability (4BSF), which can perform both stance and swing-phase knee flexion, like able-bodied gait. In the proposed conceptual design, the instantaneous center of rotation (ICR) path is repositioned during the stance phase. The ICR was placed in front of the ground reaction force (GRF) to initiate knee flexion during the loading response. The prototype was validated by a single-subject pilot study at the Gait analysis laboratory. The results showed that a person with an amputation walks with stance-phase knee flexion using the proposed 4BSF. The maximum knee flexion angle is more than 10 degrees during the stance phase. Furthermore, when the 4BSF was used with a SACH foot, the amount of time to achieve the foot flat was shorter, and the foot flat duration time was twice as long as the conventional 4-bar polycentric knee.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] KNEE FLEXION DURING STANCE AS A DETERMINANT OF INEFFICIENT WALKING
    WINTER, DA
    PHYSICAL THERAPY, 1983, 63 (03): : 331 - 333
  • [32] Design of a four-bar transfemoral polycentric prosthesis using intelligent algorithms
    Lopez-Suarez, Omar-Ismael
    Martinez-Paredes, Jonathan
    Fuerte-Hernandez, Ariel
    Campos-Lopez, Juan-Pablo
    Morales-Bonilla, Samuel
    Altamirano-Olguin, Ivan
    Taxilaga-Zetina, Oscar
    Hernandez-Valencia, Gerardo
    DYNA, 2019, 94 (01): : 11 - 11
  • [33] Design of Polycentric Assistive Device for Knee Joint
    Kikuchi, Takehito
    Nishimura, Takumi
    Fukuoka, Kenji
    Todaka, Takeru
    Abe, Isao
    2021 30TH IEEE INTERNATIONAL CONFERENCE ON ROBOT AND HUMAN INTERACTIVE COMMUNICATION (RO-MAN), 2021, : 546 - 550
  • [34] Kinematic Analysis of Polycentric Artificial Knee Joint
    Baser, Oezguen
    Cetin, Levent
    Uyar, Erol
    BIYOMUT: 2009 14TH NATIONAL BIOMEDICAL ENGINEERING MEETING, 2009, : 194 - 197
  • [35] Design of knee support device based on four-bar linkage and hydraulic artificial muscle
    Sarin Kittisares
    Hiroyuki Nabae
    Gen Endo
    Koichi Suzumori
    Ryo Sakurai
    ROBOMECH Journal, 7
  • [36] Design of knee support device based on four-bar linkage and hydraulic artificial muscle
    Kittisares, Sarin
    Nabae, Hiroyuki
    Endo, Gen
    Suzumori, Koichi
    Sakurai, Ryo
    ROBOMECH JOURNAL, 2020, 7 (01):
  • [37] Knee Joint Biomechanics in High Flexion
    Hirokawa, Shunji
    Kiguchi, Kazuo
    Todo, Mitsugu
    Mody, Bharat
    Thambyah, Ashvin
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [38] Mobility function of a prosthetic knee joint with an automatic stance phase lock
    Andrysek, Jan
    Klejman, Susan
    Torres-Moreno, Ricardo
    Heim, Winfried
    Steinnagel, Bryan
    Glasford, Shane
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2011, 35 (02) : 163 - 170
  • [39] ANALYSIS OF KNEE-JOINT FORCES DURING FLEXED KNEE STANCE
    FORD, WR
    PERRY, J
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1972, A 54 (05): : 1118 - &
  • [40] Stance and swing phase knee flexion recover at different rates following total knee arthroplasty: An inertial measurement unit study
    Chapman, Ryan M.
    Moschetti, Wayne E.
    Van Citters, Douglas W.
    JOURNAL OF BIOMECHANICS, 2019, 84 : 129 - 137