A case study on detection and sizing of defects in steam generator tubes using eddy current testing

被引:17
|
作者
Hur, Do Haeng [1 ]
Choi, Myung Sik [1 ]
Lee, Deok Hyun [1 ]
Kim, Seon Jin [2 ]
Han, Jung Ho [1 ]
机构
[1] Korea Atom Energy Res Inst, Taejon 305353, South Korea
[2] Hanyang Univ, Div Mat Sci & Engn, Seoul 133791, South Korea
关键词
CORROSION; FRANCE;
D O I
10.1016/j.nucengdes.2009.10.006
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Eddy current testing (ECT) method is widely used to detect various types of defects occurring in nuclear steam generator tubes. Therefore, the reliability of its detection and sizing accuracy for defects should be validated. For this purpose, two tubes with defect signals were pulled from an operating steam generator and destructively examined. The defect type was a circumferential crack for one tube and an intergranular attack (IGA) for the other tube. The plus point coil probe showed a better capability to detect and size both a circumferential crack and a volumetric IGA than pancake and bobbin coil probe. The destructive results are correlated with the ECT results obtained during the in-service inspection. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:204 / 208
页数:5
相关论文
共 50 条
  • [41] Defect profiling using multi-frequency eddy current data from steam generator tubes
    Arunachalam, Kavitha
    Uduebho, Oseghale
    Joshi, Ameet
    Arun Kumar, Shiva
    Udpa, Lalita
    Ramuhalli, Pradeep
    Udpa, Satish S.
    Benson, James
    Studies in Applied Electromagnetics and Mechanics, 2007, 28 : 131 - 138
  • [42] A signal processing method for eddy current testing of steam generator tubing
    Chen, GZ
    Yoshida, Y
    Miya, K
    Yamaguchi, A
    NONLINEAR ELECTROMAGNETIC SYSTEMS, 1996, 10 : 728 - 731
  • [43] Estimating statistical properties of eddy-current signals from steam generator tubes
    Dògandzic, A
    Xiang, P
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2005, 53 (08) : 3342 - 3348
  • [44] Influence of sodium deposits in steam generator tubes on remote field eddy current signals
    Thirunavukkarasu, S.
    Rao, B. P. C.
    Vaidyanathan, S.
    Jayakumar, T.
    Raj, Baldev
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2008, 85 (04) : 211 - 218
  • [45] Remote field eddy current technique applied to the inspection of nonmagnetic steam generator tubes
    Shin, YK
    Chung, TE
    Lord, W
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 20A AND 20B, 2001, 557 : 392 - 399
  • [46] Shape estimation of defects on steam generator tubes
    Shiraishi, K
    Izumida, M
    Murakami, K
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 17A AND 17B, 1998, : 783 - 790
  • [47] Optimized Eddy Current Detection of Small Cracks in Steam Generator Tubing
    Radu C. Popa
    Kenzo Miya
    Masaaki Kurokawa
    Journal of Nondestructive Evaluation, 1997, 16 (3) : 161 - 173
  • [48] Detection and sizing of defects in control rod drive mechanism penetrations using eddy current and ultrasonics
    Light, GM
    Fisher, JL
    Tennis, RF
    Stolte, JS
    Hendrix, GJ
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 301 - 307
  • [49] Optimized eddy current detection of small cracks in steam generator tubing
    Popa, RC
    Miya, K
    Kurokawa, M
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 1997, 16 (03) : 161 - 173
  • [50] Optimized eddy current detection of small cracks in steam generator tubing
    Popa R.C.
    Miya K.
    Kurokawa M.
    Journal of Nondestructive Evaluation, 1997, 16 (3) : 161 - 173