A case study on detection and sizing of defects in steam generator tubes using eddy current testing

被引:17
|
作者
Hur, Do Haeng [1 ]
Choi, Myung Sik [1 ]
Lee, Deok Hyun [1 ]
Kim, Seon Jin [2 ]
Han, Jung Ho [1 ]
机构
[1] Korea Atom Energy Res Inst, Taejon 305353, South Korea
[2] Hanyang Univ, Div Mat Sci & Engn, Seoul 133791, South Korea
关键词
CORROSION; FRANCE;
D O I
10.1016/j.nucengdes.2009.10.006
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Eddy current testing (ECT) method is widely used to detect various types of defects occurring in nuclear steam generator tubes. Therefore, the reliability of its detection and sizing accuracy for defects should be validated. For this purpose, two tubes with defect signals were pulled from an operating steam generator and destructively examined. The defect type was a circumferential crack for one tube and an intergranular attack (IGA) for the other tube. The plus point coil probe showed a better capability to detect and size both a circumferential crack and a volumetric IGA than pancake and bobbin coil probe. The destructive results are correlated with the ECT results obtained during the in-service inspection. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:204 / 208
页数:5
相关论文
共 50 条
  • [31] Investigation of frequency mixing techniques for eddy current testing of steam generator tubes in nuclear power plants
    Jung, H. J.
    Kong, Y. B.
    Song, S.-J.
    Kim, C.-H.
    Choi, Y. H.
    Kang, S.-C.
    Song, M. H.
    Review of Progress in Quantitative Nondestructive Evaluation, Vols 26A and 26B, 2007, 894 : 603 - 610
  • [32] Analysis of characteristics of eddy-current signals from steam generator tubes using wavelets
    Chen, GZ
    Yamaguchi, A
    APPLIED ELECTROMAGNETICS, 1996, 5 : 1 - 6
  • [33] Inversion of experimental eddy current testing signals obtained from steam generator tubes - Approach and automated system
    Kim, YH
    Song, SJ
    Heol, JS
    Kim, EL
    Yim, CJ
    Choi, YH
    Kang, SC
    Song, MH
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (IX), 2005, 25 : 85 - 92
  • [34] Investigation of Eddy Current Examination on OD Fatigue Crack for Steam Generator Tubes
    Kong, Yuying
    Ding, Boyuan
    Li, Ming
    Liu, Jinhong
    Chen, Huaidong
    Meyendorf, Norbert G.
    SMART MATERIALS AND NONDESTRUCTIVE EVALUATION FOR ENERGY SYSTEMS 2015, 2015, 9439
  • [35] Distinguishing signals from noise in eddy current inspection of steam generator tubes
    Basart, JP
    Chuang, SF
    Moulder, JC
    NONDESTRUCTIVE EVALUATION OF MATERIALS AND COMPOSITES, 1996, 2944 : 201 - 209
  • [36] A statistical model for eddy-current signals from steam generator tubes
    Dogandzic, A
    Xiang, P
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 23A AND 23B, 2004, 23 : 605 - 612
  • [37] A new serpentine array eddy current probe for steam generator tubes inspection
    Zhao, Lei
    Hu, Minghui
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 377
  • [38] Inversion of eddy current test signals obtained from steam generator tubes
    Kim, YH
    Song, SJ
    Hur, JS
    Kim, EL
    Yim, CJ
    Choi, YH
    Kang, SC
    Song, MH
    ADVANCES IN FRACTURE AND STRENGTH, PTS 1- 4, 2005, 297-300 : 2219 - 2224
  • [39] Simulation of Cracks Detection in Tubes by Eddy Current Testing
    Bennoud, S.
    Zergoug, M.
    INTERNATIONAL JOURNAL OF MULTIPHYSICS, 2016, 10 (04) : 417 - 426
  • [40] Discrimination method of through-wall cracks in steam generator tubes using eddy current signals
    Hur, DH
    Lee, DH
    Choi, MS
    Lee, UC
    Kim, SJ
    Han, JH
    NDT & E INTERNATIONAL, 2006, 39 (05) : 361 - 366