Numerical jitter estimation for swept source optical coherence tomography

被引:1
|
作者
Zhu, Lida [1 ]
Miyazawa, Arata [1 ]
Mukherjee, Pradipta [1 ]
Abd El-Sadek, Ibrahim [1 ]
Oikawa, Kensuke [1 ]
Oida, Daisuke [1 ]
Yasuno, Yoshiaki [1 ]
机构
[1] Univ Tsukuba, Computat Opt Grp, 1-1-1 Tennodai, Tsukuba, Ibaraki 3058573, Japan
关键词
Optical coherence tomography; swept source; jitter; numerical; phase stabilization; HUMAN SKIN;
D O I
10.1117/12.2573281
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Due to asynchronization between the acquisition trigger and K-clock trigger in a swept source optical coherence tomography (SS-OCT) system, trigger jitter causes the spectrum a temporal shift in the spectral domain and thus corrupts the measurement. We study ternary distribution of the jitter signal by measuring TiO2 phantom using a SS-OCT system, and it shows one-pixel spectral shift in the spectral domain.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Phase calculation with a swept source in optical coherence tomography: Jitter influence
    Munoz Moreno, Gilberto
    Alcala Ochoa, Noe
    [J]. OPTICS AND LASERS IN ENGINEERING, 2011, 49 (06) : 663 - 667
  • [2] Swept Source Optical Coherence Tomography: a Review
    Yasin Alibhai A.
    Or C.
    Witkin A.J.
    [J]. Current Ophthalmology Reports, 2018, 6 (1) : 7 - 16
  • [3] Advances in swept-source optical coherence tomography and optical coherence tomography angiography
    Zheng, Fang
    Deng, Xiaofeng
    Zhang, Qi
    He, Jingliang
    Ye, Panpan
    Liu, Shan
    Li, Peng
    Zhou, Jian
    Fang, Xiaoyun
    [J]. ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (02): : 67 - 79
  • [4] Swept source optical coherence tomography in globe perforation
    Dubey, Devashish
    Shanmugam, Mahesh
    Ramanjulu, Rajesh
    Mishra, K. C. Divyansh
    Doshi, Bindiya
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (10) : 1697 - +
  • [5] Handheld swept source optical coherence tomography angiography
    Liu, Gangjun
    Yang, Jianlong
    Liu, Liang
    Campbell, J. Peter
    Huang, David
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [6] Fast Broadband Swept Source for Optical Coherence Tomography
    Cordes, A. H.
    Vilela de Faria, G.
    von der Weid, J. P.
    [J]. 2009 SBMO/IEEE MTT-S INTERNATIONAL MICROWAVE AND OPTOELECTRONICS CONFERENCE (IMOC 2009), 2009, : 143 - 146
  • [7] MHz Swept Source Optical Coherence Tomography of the Choriocapillaris
    Schmoll, Tilman
    Niederleithner, Michael
    Britten, Anja
    Matten, Philipp
    Bello, Simon
    Kubach, Sophie
    Drexler, Wolfgang
    Leitgeb, Rainer
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (11)
  • [8] Swept Source optical coherence tomography of choroidal nevi
    Michalewska, Zofia
    Michalewski, Janusz
    Nawrocki, Jerzy
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2016, 51 (04): : 271 - 276
  • [9] Swept source optical coherence tomography and optical coherence tomography angiography in central serous chorioretinopathy
    Hager, Ben Amor
    Namsia, Walid
    Yasmine, Walha
    Arije, Jouini
    Eya, Essassi
    Sana, Khochtali
    Moncef, Khairallah
    [J]. ACTA OPHTHALMOLOGICA, 2024, 102
  • [10] Paper Insulation Aging Estimation Using Swept-Source Optical Coherence Tomography
    Mezgebo, Biniyam
    Sherif, Sherif S.
    Fernando, Namal
    Kordi, Behzad
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2022, 29 (01) : 30 - 37