Bearing fault detection and fault size estimation using fiber-optic sensors

被引:53
|
作者
Alian, Hasib [1 ]
Konforty, Shlomi [2 ]
Ben-Simon, Uri [3 ]
Klein, Renata [4 ]
Tur, Moshe [5 ]
Bortman, Jacob [2 ]
机构
[1] IAF, Tel Aviv, Israel
[2] Ben Gurion Univ Negev, Dept Mech Engn, PHM Lab, POB 653, IL-84105 Beer Sheva, Israel
[3] Israel Aerosp Ind, Lod, Israel
[4] RK Diagnost, POB 101, Gilon, Dn Misgav, Israel
[5] Tel Aviv Univ, Sch Elect Engn, IL-69978 Ramat Aviv, Israel
关键词
Spall size; Fault diagnosis; Rolling element bearing; Fiber; Bragg grating; PROGNOSTICS;
D O I
10.1016/j.ymssp.2018.10.035
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Health monitoring of rotating machinery is commonly based on vibration signals. Instead, this pioneering research provides bearing diagnostics using strain measurements, obtained from Fiber Bragg Grating (FBG) fiber-optic sensors. Besides detection of the damage via spectral data, these optical sensors also allow the estimation of damage severity through the direct and accurate measurement of the damage size of small spalls in the bearing races, an essential capability for the prognosis of remaining useful life. FBG sensors are small and can be easily placed in the immediate proximity of the bearing or even embedded inside it, thereby ensuring much enhanced signal-to-noise ratio through the minimizing transmission path effects from remote disturbances. These ball-bearing related diagnostic capabilities of FBG sensors are demonstrated via seeded tests, as well as by means of extended monitoring of bearings during fatigue endurance tests. Sensitivity to FBG sensor location is studied, showing acceptable values at all housing measuring points around the bearing. Fiber-optic sensors appear to have promising diagnostic potential for spall-like faults in both the outer and inner races of ball bearings with a very good discrimination power. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:392 / 407
页数:16
相关论文
共 50 条
  • [21] Optoacoustic imaging using fiber-optic interferometric sensors
    Lamela, Horacio
    Gallego, Daniel
    Oraevsky, Alexander
    OPTICS LETTERS, 2009, 34 (23) : 3695 - 3697
  • [22] Calibration of fiber-optic sensors using universal approximators
    Porada, E.
    Bock, W.J.
    Conference Record - IEEE Instrumentation and Measurement Technology Conference, 1994, 1 : 269 - 272
  • [23] Bridge Monitoring Using Brillouin Fiber-Optic Sensors
    Minardo, Aldo
    Bernini, Romeo
    Amato, Lucio
    Zeni, Luigi
    IEEE SENSORS JOURNAL, 2012, 12 (01) : 145 - 150
  • [24] Fiber-optic sensors and array sensors.
    Michael, KL
    Walt, DR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 212 : 55 - IEC
  • [25] Floor Pressure Imaging for Fall Detection with Fiber-Optic Sensors
    Feng, Guodong
    Mai, Jiechao
    Ban, Zhen
    Guo, Xuemei
    Wang, Guoli
    IEEE PERVASIVE COMPUTING, 2016, 15 (02) : 40 - 47
  • [26] Fiber-optic sensors based on fiber-optic lasers and microoptomechanical resonance structures
    Egorov, F.
    Potapov, V.
    LASER PHYSICS, 2011, 21 (02) : 299 - 303
  • [27] Force detection using a fiber-optic cantilever
    Budakian, R
    Putterman, SJ
    APPLIED PHYSICS LETTERS, 2002, 81 (11) : 2100 - 2102
  • [28] Fiber-optic sensors for the estimation of oxygen gradients within biofilms on metals
    Ganesh, A. Balaji
    Radhakrishnan, T. K.
    OPTICS AND LASERS IN ENGINEERING, 2008, 46 (04) : 321 - 327
  • [29] Fiber-optic sensors for the estimation of pH within natural biofilms on metals
    Ganesh, A. Balaji
    Radhakrishnan, T. K.
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (02): : 1107 - 1112
  • [30] Fiber-Optic Skew Ray Sensors
    Chen, George Y.
    Wang, Jinyu
    Lancaster, David G.
    SENSORS, 2020, 20 (09)