Quantitative Comparison of 3D Freehand Ultrasound and MRI Images of the Neonatal Brain

被引:0
|
作者
Blanchard, Martin [1 ]
Martin, Matthieu [1 ]
Quetin, Philippe [2 ]
Delachartre, Philippe [1 ]
机构
[1] Univ Claude Bernard Lyon 1, Univ Lyon, INSA Lyon, UJM St Etienne,CNRS,INSERM,CREATIS UMR 5220,U1206, F-69100 Lyon, France
[2] CH Avignon, Avignon, France
关键词
3d ultrasound; MRI; preterm neonates; brain imaging; brain structure comparison; 2D;
D O I
10.1109/ius46767.2020.9251324
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Premature neonates' care can be improved by a quantitative evaluation of brain structures. In current clinical practice, first-line diagnosis is done qualitatively with 2D cranial ultrasonography (cUS) images. These patients would benefit from an evolution to a quantitative analysis based on 3D cUS. A way to obtain high quality 3D cUS images is to use a reconstruction algorithm based on the clinician acquisition motion. In this paper we assess the accuracy of such reconstruction by comparing brain structures between MRI and 3D renconstructed cUS. This comparison was performed based on manual contours, we obtained a mean Dice value of 0.72 +/- 0.05 for thalami and ventricles and a mean volume error of 10 +/- 5.7%. In addition, the contour interpolation method that we used significantly improved Dice and volume error compared to nearest neighbor approach.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Real-time freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Graham, Andrew H. Gee
    Treece, Graham M.
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [42] Probe trajectory interpolation for 3D reconstruction of freehand ultrasound
    Coupe, Pierrick
    Hellier, Pierre
    Morandi, Xavier
    Barillot, Christian
    MEDICAL IMAGE ANALYSIS, 2007, 11 (06) : 604 - 615
  • [43] An optical registration method for 3D ultrasound freehand scanning
    Poulsen, C
    Pedersen, PC
    Szabo, TL
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 1236 - 1240
  • [44] 3D freehand ultrasound reconstruction based on probe trajectory
    Coupé, P
    Hellier, P
    Azzabou, N
    Barillot, C
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 1, 2005, 3749 : 597 - 604
  • [45] Non-planar reslicing for freehand 3D ultrasound
    Gee, A
    Prager, R
    Berman, L
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 716 - 725
  • [46] Localization of liver tumors in freehand 3D laparoscopic ultrasound
    Shahin, O.
    Martens, V.
    Besirevic, A.
    Kleemann, M.
    Schlaefer, A.
    MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316
  • [47] Correction of probe pressure artifacts in freehand 3D ultrasound
    Treece, GM
    Prager, RW
    Gee, AH
    Berman, L
    MEDICAL IMAGE ANALYSIS, 2002, 6 (03) : 199 - 214
  • [48] Accurate fiducial location for freehand 3D ultrasound calibration
    Hsu, Po-Wei
    Prager, Richard W.
    Houghton, Neil E.
    Gee, Andrew H.
    Treece, Graham M.
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [49] 3D freehand ultrasound to estimate the glenohumeral rotation centre
    Lempereur, M.
    Kostur, L.
    Leboucher, J.
    Brochard, S.
    Remy-Neris, O.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 : 214 - 215
  • [50] Intensity-based registration of freehand 3D ultrasound and CT-scan images of the kidney
    Leroy, Antoine
    Mozer, Pierre
    Payan, Yohan
    Troccaz, Jocelyne
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 (01) : 31 - 41