Quantitative Comparison of 3D Freehand Ultrasound and MRI Images of the Neonatal Brain

被引:0
|
作者
Blanchard, Martin [1 ]
Martin, Matthieu [1 ]
Quetin, Philippe [2 ]
Delachartre, Philippe [1 ]
机构
[1] Univ Claude Bernard Lyon 1, Univ Lyon, INSA Lyon, UJM St Etienne,CNRS,INSERM,CREATIS UMR 5220,U1206, F-69100 Lyon, France
[2] CH Avignon, Avignon, France
关键词
3d ultrasound; MRI; preterm neonates; brain imaging; brain structure comparison; 2D;
D O I
10.1109/ius46767.2020.9251324
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Premature neonates' care can be improved by a quantitative evaluation of brain structures. In current clinical practice, first-line diagnosis is done qualitatively with 2D cranial ultrasonography (cUS) images. These patients would benefit from an evolution to a quantitative analysis based on 3D cUS. A way to obtain high quality 3D cUS images is to use a reconstruction algorithm based on the clinician acquisition motion. In this paper we assess the accuracy of such reconstruction by comparing brain structures between MRI and 3D renconstructed cUS. This comparison was performed based on manual contours, we obtained a mean Dice value of 0.72 +/- 0.05 for thalami and ventricles and a mean volume error of 10 +/- 5.7%. In addition, the contour interpolation method that we used significantly improved Dice and volume error compared to nearest neighbor approach.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Freehand 3D ultrasound reconstruction algorithms - A review
    Solberg, Ole Vegard
    Lindseth, Frank
    Torp, Hans
    Blake, Richard E.
    Hernes, Toril A. Nagelhus
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (07): : 991 - 1009
  • [22] Sensorless reconstruction of freehand 3D ultrasound data
    Housden, R. James
    Gee, Andrew H.
    Treece, Graham M.
    Prager, Richard W.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 2, 2006, 4191 : 356 - 363
  • [23] Trackerless 3D Freehand Ultrasound Reconstruction: A Review
    Adriaans, Chrissy A.
    Wijkhuizen, Mark
    van Karnenbeek, Lennard M.
    Geldof, Freija
    Dashtbozorg, Behdad
    APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [24] TOWARDS 3D REGISTRATION OF FETAL BRAIN MRI AND ULTRASOUND
    Kuklisova-Murgasova, Maria
    Quaghebeur, Gerardine
    Hajnal, Joseph V.
    Noble, J. Alison
    Schnabel, Julia A.
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 346 - 349
  • [25] A hybrid method for 3D segmentation of MRI Brain Images
    Zhang, X
    Zhang, DZ
    Tian, JW
    Liu, J
    2002 6TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS, VOLS I AND II, 2002, : 608 - 611
  • [26] A Novel Multiparametric Approach to 3D Quantitative MRI of the Brain
    Palma, Giuseppe
    Tedeschi, Enrico
    Borrelli, Pasquale
    Cocozza, Sirio
    Russo, Carmela
    Liu, Saifeng
    Ye, Yongquan
    Comerci, Marco
    Alfano, Bruno
    Salvatore, Marco
    Haacke, E. Mark
    Mancini, Marcello
    PLOS ONE, 2015, 10 (08):
  • [27] The 3D Moore-Rayleigh Test for the Quantitative Groupwise Comparison of MR Brain Images
    Scheenstra, Alize E. H.
    Muskulus, Michael
    Staring, Marius
    van den Maagdenberg, Arn M. J. V.
    Lunel, Sjoerd Verduyn
    Reiber, J. Hans C.
    van der Weerd, Louise
    Dijkstra, Jouke
    INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 2009, 5636 : 564 - +
  • [28] Real-time tools for freehand 3D ultrasound
    Prager, R
    Gee, A
    Berman, L
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI'98, 1998, 1496 : 1016 - 1023
  • [29] Reconstruction of freehand 3D ultrasound based on kernel regression
    Xiankang Chen
    Tiexiang Wen
    Xingmin Li
    Wenjian Qin
    Donglai Lan
    Weizhou Pan
    Jia Gu
    BioMedical Engineering OnLine, 13
  • [30] Sensorless reconstruction of unconstrained freehand 3D ultrasound data
    Housden, R. James
    Gee, Andrew H.
    Treece, Graham M.
    Prager, Richard W.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (03): : 408 - 419