Total hip arthroplasty using a three-dimensional porous titanium acetabular cup: an examination of micromotion using subject-specific finite element analysis

被引:6
|
作者
Miyagawa, Takaki [1 ]
Matsumoto, Kazu [1 ]
Komura, Shingo [1 ]
Akiyama, Haruhiko [1 ]
机构
[1] Gifu Univ, Dept Orthopaed Surg, Sch Med, Yanagido 1-1, Gifu 5011194, Japan
关键词
Finite element analysis; Total hip arthroplasty; Three-dimensional porous structure; Radiolucent line;
D O I
10.1186/s12891-021-04174-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundWe investigated the mid-term clinical and radiological results of total hip arthroplasty (THA) using a three-dimensional (3D) porous titanium cup and analyzed the micromotion at the interface of the cup using subject-specific finite element (FE) analysis.MethodsWe evaluated 73 hips of 65 patients (6 men and 59 women; mean age at the time of surgery, 62.2years; range, 45-86years) who had undergone THA using a 3D porous titanium cup. Clinical evaluations were performed using the Japanese Orthopaedic Association (JOA) hip score system. We assessed the fixation of the acetabular component based on the presence of radiolucent lines and cup migration using anteroposterior radiographs. Subject-specific FE models were constructed from computed tomography data.ResultsThe JOA score improved from a preoperative mean of 52.2 (range, 23-82) to a mean of 87.8 (range, 71-100) at the final follow-up. None of the patients underwent revisions during the follow-up period. Radiolucent lines were observed in 26 cases (35.6%) and frequently appeared at DeLee and Charnley Zone 3. Following the FE analysis, the micromotion at DeLee and Charnley Zone 3 was significantly larger than that at Zone 2. Furthermore, micromotion was large in the groups in which radiolucent lines appeared at Zone 3.ConclusionsThe mid-term clinical outcome of THA using a 3D porous titanium cup was excellent. However, radiolucent lines frequently appeared at DeLee and Charnley Zone 3. FE analysis indicated that micromotion was large at the same site, strongly suggesting that it contributes to the emergence of radiolucent lines. The 3D porous titanium cups are useful in THA, and with improvements focused on micromotion, we anticipate better long-term outcomes.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Prediction of PD Magnitudes using Three-Dimensional Finite Element Analysis
    Guo, Jim Jun
    Boggs, Steve
    Campbell, Thomas
    2008 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2008, : 534 - +
  • [42] Clinical and radiological outcomes of total hip arthroplasty using a highly porous titanium cup or a conventional hydroxyapatite-coated titanium cup: A retrospective study in Japanese patients
    Tamaki, Yasuaki
    Goto, Tomohiro
    Takasago, Tomoya
    Wada, Keizo
    Hamada, Daisuke
    Sairyo, Koichi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2022, 27 (01) : 163 - 168
  • [43] Prediction of the mechanical response of canine humerus to three-point bending using subject-specific finite element modelling
    Laurent, Cedric P.
    Bohme, Beatrice
    Mengoni, Marlene
    d'Otreppe, Vinciane
    Balligand, Marc
    Ponthot, Jean-Philippe
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (07) : 639 - 649
  • [44] Three-Dimensional Finite Element Analysis of Cement-Cup Junction in Total Hip Prosthesis: Mechanical Stress Distribution, Crack Initiation and Rupture Dynamics
    Bounoua, Noureddine
    Belhouari, Mohamed
    Menni, Younes
    Alkhafaji, Mohammed Ayad
    Bayram, Mustafa
    Ikumapayi, Omolayo M.
    Chamkha, Ali J.
    NANO, 2025, 20 (04)
  • [45] Sagittal pelvic mal-rotation and positioning of the acetabular component in total hip arthroplasty: Three-dimensional computer model analysis
    Tang, W. M.
    Chiu, K. Y.
    Kwan, M. F. Y.
    Ng, T. P.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2007, 25 (06) : 766 - 771
  • [46] Mechanical behaviour investigation of PEEK coated titanium alloys for hip arthroplasty using finite element analysis
    Belwanshi, Manish
    Jayaswal, Pratesh
    Aherwar, Amit
    MATERIALS TODAY-PROCEEDINGS, 2022, 56 : 2808 - 2817
  • [47] Three-Dimensional Subject-Specific Knee Shape Reconstruction with Asynchronous Fluoroscopy Images Using Statistical Shape Modeling
    Lu, Hsuan-Yu
    Shih, Kao-Shang
    Lin, Cheng-Chung
    Lu, Tung-Wu
    Li, Song-Ying
    Kuo, Hsin-Wen
    Hsu, Horng-Chaung
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [48] Quantification of Patellofemoral Joint Reaction Forces During Functional Activities Using a Subject-Specific Three-Dimensional Model
    Chen, Yu-Jen
    Scher, Irving
    Powers, Christopher M.
    JOURNAL OF APPLIED BIOMECHANICS, 2010, 26 (04) : 415 - 423
  • [49] Radiographic assessment of radiolucent lines around a highly porous titanium cup (Tritanium) using digital tomosynthesis, after total hip arthroplasty
    Kazuki Oishi
    Yuji Yamamoto
    Yoshifumi Harada
    Ryo Inoue
    Eiji Sasaki
    Yasuyuki Ishibashi
    Journal of Orthopaedic Surgery and Research, 16
  • [50] Radiographic assessment of radiolucent lines around a highly porous titanium cup (Tritanium) using digital tomosynthesis, after total hip arthroplasty
    Oishi, Kazuki
    Yamamoto, Yuji
    Harada, Yoshifumi
    Inoue, Ryo
    Sasaki, Eiji
    Ishibashi, Yasuyuki
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)