Total hip arthroplasty using a three-dimensional porous titanium acetabular cup: an examination of micromotion using subject-specific finite element analysis

被引:6
|
作者
Miyagawa, Takaki [1 ]
Matsumoto, Kazu [1 ]
Komura, Shingo [1 ]
Akiyama, Haruhiko [1 ]
机构
[1] Gifu Univ, Dept Orthopaed Surg, Sch Med, Yanagido 1-1, Gifu 5011194, Japan
关键词
Finite element analysis; Total hip arthroplasty; Three-dimensional porous structure; Radiolucent line;
D O I
10.1186/s12891-021-04174-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundWe investigated the mid-term clinical and radiological results of total hip arthroplasty (THA) using a three-dimensional (3D) porous titanium cup and analyzed the micromotion at the interface of the cup using subject-specific finite element (FE) analysis.MethodsWe evaluated 73 hips of 65 patients (6 men and 59 women; mean age at the time of surgery, 62.2years; range, 45-86years) who had undergone THA using a 3D porous titanium cup. Clinical evaluations were performed using the Japanese Orthopaedic Association (JOA) hip score system. We assessed the fixation of the acetabular component based on the presence of radiolucent lines and cup migration using anteroposterior radiographs. Subject-specific FE models were constructed from computed tomography data.ResultsThe JOA score improved from a preoperative mean of 52.2 (range, 23-82) to a mean of 87.8 (range, 71-100) at the final follow-up. None of the patients underwent revisions during the follow-up period. Radiolucent lines were observed in 26 cases (35.6%) and frequently appeared at DeLee and Charnley Zone 3. Following the FE analysis, the micromotion at DeLee and Charnley Zone 3 was significantly larger than that at Zone 2. Furthermore, micromotion was large in the groups in which radiolucent lines appeared at Zone 3.ConclusionsThe mid-term clinical outcome of THA using a 3D porous titanium cup was excellent. However, radiolucent lines frequently appeared at DeLee and Charnley Zone 3. FE analysis indicated that micromotion was large at the same site, strongly suggesting that it contributes to the emergence of radiolucent lines. The 3D porous titanium cups are useful in THA, and with improvements focused on micromotion, we anticipate better long-term outcomes.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Load Dispersion Effects of Acetabular Reinforcement Devices Used in Revision Total Hip Arthroplasty A Simulation Study Using Finite Element Analysis
    Kawanabe, Keiichi
    Akiyama, Haruhiko
    Goto, Koji
    Maeno, Sumihiko
    Nakamura, Takashi
    JOURNAL OF ARTHROPLASTY, 2011, 26 (07): : 1061 - 1066
  • [32] Accuracy of measuring acetabular cup position after total hip arthroplasty: comparison between a radiographic planning software and three-dimensional computed tomography
    Bayraktar, Vahdettin
    Weber, Markus
    von Kunow, Frederik
    Zeman, Florian
    Craiovan, Benjamin
    Renkawitz, Tobias
    Grifka, Joachim
    Woerner, Michael
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (04) : 731 - 738
  • [33] Cup positioning relative to the acetabular rim planned with three-dimensional computed tomography improves precision in total hip arthroplasty: a randomized controlled trial
    Pongkunakorn, Anuwat
    Wongkamthong, Napon
    Ruktrakul, Rukthanin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [34] Accuracy of measuring acetabular cup position after total hip arthroplasty: comparison between a radiographic planning software and three-dimensional computed tomography
    Vahdettin Bayraktar
    Markus Weber
    Frederik von Kunow
    Florian Zeman
    Benjamin Craiovan
    Tobias Renkawitz
    Joachim Grifka
    Michael Woerner
    International Orthopaedics, 2017, 41 : 731 - 738
  • [35] Nonlinear three-dimensional finite element analysis of newly designed cementless total hip stems
    Ando, M
    Imura, S
    Omori, H
    Okumura, Y
    Bo, A
    Baba, H
    ARTIFICIAL ORGANS, 1999, 23 (04) : 339 - 346
  • [36] Bone ingrowth around porous-coated acetabular implant: a three-dimensional finite element study using mechanoregulatory algorithm
    Mukherjee, Kaushik
    Gupta, Sanjay
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2016, 15 (02) : 389 - 403
  • [37] Bone ingrowth around porous-coated acetabular implant: a three-dimensional finite element study using mechanoregulatory algorithm
    Kaushik Mukherjee
    Sanjay Gupta
    Biomechanics and Modeling in Mechanobiology, 2016, 15 : 389 - 403
  • [38] Subject-specific identification of three dimensional foot shape deviations using statistical shape analysis
    Stankovic, Kristina
    Huysmans, Toon
    Danckaers, Femke
    Sijbers, Jan
    Booth, Brian G.
    EXPERT SYSTEMS WITH APPLICATIONS, 2020, 151 (151)
  • [39] Structural analysis of three-dimensional wings using finite element method
    Aabid A.
    Zakuan M.A.M.B.M.
    Khan S.A.
    Ibrahim Y.E.
    Aerospace Systems, 2022, 5 (1) : 47 - 63