OBJECTIVE:The technique of rod-screw fixation of the cervical spine is well described. However, there is very little data on the complications incurred by the application of these devices. The purpose of this study was to quantify the risks associated with rod fixation of the cervical spine. METHODS: A prospective study was performed on 100 consecutive patients treated with this technique. Clinical and radiographic assessment was performed immediately after surgery 3, 6, and 12 months postoperatively, and annually thereafter. The mean follow-up interval was 16.7 months. RESULTS: A total of 888 screws were implanted in 100 patients. Perioperative complications included radiculopathy (n = 4, 0.45% per screw placed), infection and other wound-healing problems (n = 4), screw malposition (n = 2), loss of alignment (n = 1), and cerebrospinal fluid leak (n = 1). There were no examples of spinal cord or vertebral artery injury. Early complications (within 6 mo of surgery) included pseudarthrosis (n = 2) and screw breakage (n = 2, 0.22% per screw placed). There were no late complications. Reoperation was required in eight cases, all within 6 months of the index procedure. Indications for reoperation included wound-healing problems (n = 4), mal-positioned screw (n = 2), and pseudarthrosis (n = 2). No patient required another operation for any indication beyond the 6-month postoperative interval. CONCLUSION: Rod-screw fixation was an effective method of posterior cervical stabilization that could be safely applied in a wide range of spinal disorders. In a complex group of patients, the complication rates were modest, and compared favorably with other methods of fixation.
引用
收藏
页码:1062 / 1067
页数:6
相关论文
共 50 条
  • [21] Transpedicle screw fixation of the cervical spine
    Ludwig, SC
    Kramer, DL
    Vaccaro, AR
    Albert, TJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (359) : 77 - 88
  • [22] Effects of Lateral Mass Screw Rod Fixation to the Stability of Cervical Spine after Laminectomy
    Rosli, Ruwaida
    Kashani, Jamal
    Kadir, Mohammed Rafiq Abdul
    2011 INTERNATIONAL CONFERENCE ON PHYSICS SCIENCE AND TECHNOLOGY (ICPST), 2011, 22 : 408 - 413
  • [23] Pedicle Screw Fixation of Thoracic Spine Fractures
    Bozik, M.
    Magala, M.
    Heger, T.
    Matejicka, D.
    Baka, J.
    Simko, R.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2014, 81 (02) : 140 - 151
  • [24] The safety of pedicle screw fixation in the thoracic spine
    Yalniz, Erol
    Ciftdemir, Mert
    Eskin, Deniz
    Dulger, Hakan
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (06) : 522 - 527
  • [25] An Upper and Middle Cervical Spine Posterior Arch Defect Leading to Myelopathy and a Thoracic Spine Posterior Arch Defect
    Yun, Dong-Ju
    Hwang, Byeong-Wook
    Kim, Dae Jin
    Lee, Sang-Ho
    WORLD NEUROSURGERY, 2016, 93 : 489.e1 - 489.e5
  • [26] Posterior fixation and fusion with atlas pedicle screw system for upper cervical diseases
    李雷
    周凤华
    王欢
    崔少千
    中华创伤杂志(英文版), 2008, (06)
  • [27] Posterior fixation and fusion with atlas pedicle screw system for upper cervical diseases
    Li Lei
    Zhou Feng-hua
    Wang Huan
    Cui Shao-qian
    CHINESE JOURNAL OF TRAUMATOLOGY, 2008, 11 (06) : 323 - 328
  • [28] Pedicle screw and plate rod fixation of the thoracic and lumbar spine: Safety and efficacy in 113 patients
    Coric, D
    Branch, CL
    Graham, AW
    PERSPECTIVES IN NEUROLOGICAL SURGERY, 1995, 6 (02): : 85 - 93
  • [29] Transverse connectors providing increased stability to the cervical spine rod-screw construct: an in vitro human cadaveric study Laboratory investigation
    Shaw, Miranda N.
    Morel, Etienne P.
    Utter, P. Andrew
    Gussous, Yazeed M.
    Ginoux, Lise
    Berglund, Lawrence J.
    Gay, Ralph E.
    Krauss, William E.
    JOURNAL OF NEUROSURGERY-SPINE, 2011, 14 (06) : 719 - 725
  • [30] Biomechanical evaluation of a new modular rod-screw implant system for posterior instrumentation of the occipito-cervical spine: in-vitro comparison with two established implant systems
    M. Richter
    H.-J. Wilke
    P. Kluger
    S. Neller
    L. Claes
    W. Puhl
    European Spine Journal, 2000, 9 : 417 - 425