Intraocular Pressure and Steep Trendelenburg During Minimally Invasive Gynecologic Surgery: Is There a Risk?

被引:23
|
作者
Borahay, Mostafa A. [1 ]
Patel, Pooja R. [1 ]
Walsh, Teresa M. [1 ]
Tarnal, Vijay [2 ]
Koutrouvelis, Aristides [2 ]
Vizzeri, Gianmarco [3 ]
Jennings, Kristofer [4 ]
Jerig, Sean [1 ]
Kilic, Gokhan S. [1 ]
机构
[1] Univ Texas Med Branch, Dept Obstet & Gynecol, Galveston, TX 77555 USA
[2] Univ Texas Med Branch, Dept Anesthesiol, Galveston, TX 77555 USA
[3] Univ Texas Med Branch, Dept Ophthalmol, Galveston, TX 77555 USA
[4] Univ Texas Med Branch, Dept Prevent Med & Community Hlth, Galveston, TX 77555 USA
关键词
Intraocular pressure; Robotic surgery; Trendelenburg; BODY POSITION;
D O I
10.1016/j.jmig.2013.05.005
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Study Objective: Steep Trendelenburg position is frequently used during gynecologic minimally invasive surgery (MIS). However, little attention has been given to the potential impact of this nonphysiologic positioning on patients, specifically intraocular pressure (TOP). The purpose of our study was to evaluate TOP changes during laparoscopic or robotic hysterectomy conducted in the steep Trendelenburg position. Design: Prospective cohort study (Canadian Task Force classification II-2). Setting: John Sealy Hospital at the University of Texas Medical Branch, Galveston, TX. Patients: Female patients with no history of ocular pathology who underwent elective robotic or laparoscopic hysterectomy. Interventions: The anesthesia protocol was standardized for all study patients. TOP and mean arterial pressure (MAP) were obtained before anesthesia, after general anesthesia and intubation were achieved, after 1 hour of steep Trendelenburg positioning, after 2 hours of steep Trendelenburg positioning, and after the patient was returned to the supine position. Ocular perfusion pressure (OPP) was calculated using the following equation: OPP = MAP TOP. Main Results: A total of 10 patients were included in this prospective study. A significant increase in TOP from baseline was observed after 1 hour and 2 hours of steep Trendelenburg positioning (p = .005 and .002, respectively). There was a statistically significant trend of increasing the TOP from baseline to the second hour of steep Trendelenburg positioning (p < .001). The TOP remained significantly elevated once the patient was returned to the supine position when compared with the baseline TOP (p = .006). OPP significantly decreased from baseline after 2 hours of steep Trendelenburg positioning (p = .03). Conclusions: TOP increases significantly when patients are placed in the steep Trendelenburg position. Although further studies are needed to better characterize this process, given the aging population of our MIS patients in whom risk for glaucoma is significant, preoperative ocular health assessment should be considered in certain cases. (C) 2013 AAGL. All rights reserved.
引用
收藏
页码:819 / 824
页数:6
相关论文
共 50 条
  • [1] The Impact of Steep Trendelenburg Position on Intraocular Pressure
    Ripa, Matteo
    Schipa, Chiara
    Kopsacheilis, Nikolaos
    Nomikarios, Mikes
    Perrotta, Gerardo
    De Rosa, Carlo
    Aceto, Paola
    Sollazzi, Liliana
    De Rosa, Pasquale
    Motta, Lorenzo
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (10)
  • [2] Effect of Continuous Systemic Administration of Esmolol on Intraocular Pressure During Surgery in a Sustained Steep Trendelenburg Position
    Joo, Jin
    Kim, Jiyoung
    Lee, Jaemin
    JOURNAL OF GLAUCOMA, 2017, 26 (12) : 1068 - 1071
  • [3] Increase in intraocular pressure is less with propofol than with sevoflurane during laparoscopic surgery in the steep Trendelenburg position
    Yoo, Young-Chul
    Shin, Seokyung
    Choi, Eun Kyeong
    Kim, Chan Yun
    Choi, Young Deuk
    Bai, Sun-Joon
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2014, 61 (04): : 322 - 329
  • [4] The Effects of Steep Trendelenburg Positioning on Intraocular Pressure During Robotic Radical Prostatectomy
    Awad, Hamdy
    Santilli, Scott
    Ohr, Matthew
    Roth, Andrew
    Yan, Wendy
    Fernandez, Soledad
    Roth, Steven
    Patel, Vipul
    ANESTHESIA AND ANALGESIA, 2009, 109 (02): : 473 - 478
  • [5] INTRAOCULAR PRESSURE DURING ROBOTIC ASSISTED LAPAROSCOPIC PROCEDURES UTILIZING STEEP TRENDELENBURG POSITIONING
    L'esperance, J.
    Christman, M.
    Mondzelewski, T.
    Durbin, J.
    Lujan, E.
    Davis, K.
    Auge, B.
    JOURNAL OF ENDOUROLOGY, 2010, 24 : A46 - A47
  • [6] THE EFFECTS OF STEEP TRENDELENBURG POSITIONING ON INTRAOCULAR PRESSURE, BLOOD FLOW VELOCITIES OF THE CENTRAL RETINAL ARTERY DURING ROBOTIC SURGERY
    Ozcan, Muhammet Fuat
    Akbulut, Ziya
    Gurdal, Canan
    Tan, Sinan
    Yildiz, Yelda
    Bayraktar, Serdar
    Balbay, Mevlana Derya
    Arslan, Muhammet Ersagun
    JOURNAL OF ENDOUROLOGY, 2012, 26 : A22 - A23
  • [7] Intraocular Pressure During Robotic-assisted Laparoscopic Procedures Utilizing Steep Trendelenburg Positioning
    Mondzelewski, Todd J.
    Schmitz, Joseph W.
    Christman, Matthew S.
    Davis, Kimberly D.
    Lujan, Eugenio
    L'Esperance, James O.
    Auge, Brian K.
    JOURNAL OF GLAUCOMA, 2015, 24 (06) : 399 - 404
  • [8] Intraocular Pressure During Robotic-assisted Laparoscopic Procedures Utilizing Steep Trendelenburg Positioning
    Vitish-Sharma, Parveen
    Acheson, Austin G.
    King, Anthony J.
    JOURNAL OF GLAUCOMA, 2017, 26 (02) : E122 - E122
  • [9] Simple Enterolysis Techniques during Minimally Invasive Gynecologic Surgery
    Gonzalez, Gillian Patrick Cruz
    Lee, Chyi-Long
    Paredes, Jhanice
    Lay, Zin Mar
    Huang, Kuan-Gen
    GYNECOLOGY AND MINIMALLY INVASIVE THERAPY-GMIT, 2024, 13 (02): : 130 - 131
  • [10] Minimally invasive surgery in gynecologic practice
    Adamyan, LV
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2003, 82 (03) : 347 - 355