Development of a Wireless Sensor for the Measurement of Chicken Blood Flow Using the Laser Doppler Blood Flow Meter Technique

被引:18
|
作者
Nishihara, Kei [1 ]
Iwasaki, Wataru [1 ]
Nakamura, Masaki [1 ]
Higurashi, Eiji [2 ]
Soh, Tomoki [3 ]
Itoh, Toshihiro [4 ]
Okada, Hironao [4 ]
Maeda, Ryutaro [4 ]
Sawada, Renshi [1 ,5 ]
机构
[1] Kyushu Univ, Grad Sch Syst Life Sci, Fukuoka 8128581, Japan
[2] Univ Tokyo, Res Ctr Adv Sci & Technol, Tokyo 1130033, Japan
[3] Kyushu Univ, Grad Sch Bioresource & Bioenvironm Sci, Fukuoka 8128581, Japan
[4] Adv Ind Sci & Technol, Ibaraki 3058566, Japan
[5] Kyushu Univ, Dept Intelligent Machinery & Syst, Fukuoka 8128581, Japan
基金
日本科学技术振兴机构;
关键词
Avian influenza; blood flow; laser Doppler; low power consumption; microsensor; wireless; INFLUENZA-A H5N1; VIRUSES;
D O I
10.1109/TBME.2013.2241062
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Here, we report the development of an integrated laser Doppler blood flow micrometer for chickens. This sensor weighs only 18 g and is one of the smallest-sized blood flow meters, with no wired line, these are features necessary for attaching the sensor to the chicken. The structure of the sensor chip consists of two silicon cavities with a photo diode and a laser diode, which was achieved using the microelectromechanical systems technique, resulting in its small size and significantly low power consumption. In addition, we introduced an intermittent measuring arrangement in the measuring system to reduce power consumption and to enable the sensor to work longer. We were successfully able to measure chicken blood flow for five consecutive days, and discovered that chicken blood flow shows daily fluctuations.
引用
收藏
页码:1645 / 1653
页数:9
相关论文
共 50 条
  • [31] CONTINUOUS MEASUREMENT OF CEREBRAL BLOOD-FLOW BY LASER DOPPLER SPECTROSCOPY
    EYRE, JA
    FLECKNELL, PA
    ESSEX, TJH
    NEUROPEDIATRICS, 1987, 18 (02) : 121 - 121
  • [32] Laser doppler blood flow measurement on extracted human teeth.
    Ikawa, M
    Miwa, Z
    Iiyama, M
    Shimauchi, H
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 437 - 437
  • [33] EVALUATION OF COCHLEAR BLOOD-FLOW MEASUREMENT BY LASER DOPPLER FLOWMETRY
    TAMURA, T
    OKAMOTO, A
    KOBAYASHI, N
    YOKOYAMA, K
    HASEGAWA, M
    TOGAWA, T
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 1185 - 1186
  • [34] CONTINUOUS MEASUREMENT OF CEREBRAL BLOOD-FLOW BY LASER DOPPLER SPECTROSCOPY
    EYRE, JA
    FLECKNELL, PA
    ESSEX, TJH
    EARLY HUMAN DEVELOPMENT, 1987, 15 (03) : 185 - 186
  • [35] MEASUREMENT OF BLOOD-FLOW IN EXPANDED TISSUES BY LASER DOPPLER VELOCIMETRY
    CANADY, JW
    SQUIER, CA
    BARDACH, J
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1987, 97 (02) : 167 - 167
  • [36] Laser Doppler flowmetry for measurement of laminar capillary blood flow in the horse
    Adair, HS
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS VIII, PROCEEDINGS OF, 1998, 3245 : 422 - 425
  • [37] EVALUATION OF A LASER DOPPLER FLOWMETER FOR MEASUREMENT OF TISSUE BLOOD-FLOW
    NILSSON, GE
    TENLAND, T
    OBERG, PA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (10) : 597 - 604
  • [38] Reliability of Skin Blood Flow Measurement with Multiple Laser Doppler Probes
    Cui, Jian
    Kunselman, Allen
    Herr, Michael
    Pai, Samuel
    Blaha, Cheryl
    Luck, Jonathan
    Sinoway, Lawrence
    FASEB JOURNAL, 2020, 34
  • [39] LASER DOPPLER MEASUREMENT OF ORAL MUCOSAL BLOOD-FLOW FOR PROSTHODONTICS
    OHKAWA, S
    KATAYAMA, S
    IGARASHI, Y
    SHIBA, A
    JOURNAL OF DENTAL RESEARCH, 1989, 68 (04) : 677 - 677
  • [40] MEASUREMENT OF LOCAL TISSUE BLOOD-FLOW BY LASER DOPPLER SPECTROSCOPY
    STERN, MD
    LAPPE, DL
    FEDERATION PROCEEDINGS, 1976, 35 (03) : 234 - 234