Development of a Wireless Sensor for the Measurement of Chicken Blood Flow Using the Laser Doppler Blood Flow Meter Technique

被引:18
|
作者
Nishihara, Kei [1 ]
Iwasaki, Wataru [1 ]
Nakamura, Masaki [1 ]
Higurashi, Eiji [2 ]
Soh, Tomoki [3 ]
Itoh, Toshihiro [4 ]
Okada, Hironao [4 ]
Maeda, Ryutaro [4 ]
Sawada, Renshi [1 ,5 ]
机构
[1] Kyushu Univ, Grad Sch Syst Life Sci, Fukuoka 8128581, Japan
[2] Univ Tokyo, Res Ctr Adv Sci & Technol, Tokyo 1130033, Japan
[3] Kyushu Univ, Grad Sch Bioresource & Bioenvironm Sci, Fukuoka 8128581, Japan
[4] Adv Ind Sci & Technol, Ibaraki 3058566, Japan
[5] Kyushu Univ, Dept Intelligent Machinery & Syst, Fukuoka 8128581, Japan
基金
日本科学技术振兴机构;
关键词
Avian influenza; blood flow; laser Doppler; low power consumption; microsensor; wireless; INFLUENZA-A H5N1; VIRUSES;
D O I
10.1109/TBME.2013.2241062
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Here, we report the development of an integrated laser Doppler blood flow micrometer for chickens. This sensor weighs only 18 g and is one of the smallest-sized blood flow meters, with no wired line, these are features necessary for attaching the sensor to the chicken. The structure of the sensor chip consists of two silicon cavities with a photo diode and a laser diode, which was achieved using the microelectromechanical systems technique, resulting in its small size and significantly low power consumption. In addition, we introduced an intermittent measuring arrangement in the measuring system to reduce power consumption and to enable the sensor to work longer. We were successfully able to measure chicken blood flow for five consecutive days, and discovered that chicken blood flow shows daily fluctuations.
引用
收藏
页码:1645 / 1653
页数:9
相关论文
共 50 条
  • [21] LASER DOPPLER FLOWMETRY FOR MEASUREMENT OF LIVER BLOOD-FLOW
    ARVIDSSON, D
    SVENSSON, H
    HAGLUND, U
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1986, 5 (2-3): : 204 - 204
  • [22] Pulpal blood flow recorded from exposed dentine with a laser Doppler flow meter using red or infrared light
    Kijsamanmith, Kanittha
    Vongsavan, Noppakun
    Matthews, Bruce
    ARCHIVES OF ORAL BIOLOGY, 2018, 87 : 163 - 167
  • [23] CUTANEOUS BLOOD-FLOW AND PERCUTANEOUS-ABSORPTION - A QUANTITATIVE-ANALYSIS USING A LASER DOPPLER-VELOCIMETER AND A BLOOD-FLOW METER
    PERSHING, LK
    HUETHER, S
    CONKLIN, RL
    KRUEGER, GG
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1989, 92 (03) : 355 - 359
  • [24] CORRELATION OF CUTANEOUS BLOOD-FLOW BETWEEN A LASER DOPPLER-VELOCIMETER AND AN ELECTROMAGNETIC BLOOD-FLOW METER USING THE SKIN SANDWICH FLAP
    PERSHING, LK
    LAMBERT, L
    KRUEGER, GG
    CLINICAL RESEARCH, 1987, 35 (01): : A181 - A181
  • [25] LASER DOPPLER FLOW METER
    WUNDERLICH, RW
    FOLGER, RL
    WARE, BR
    GIDDON, DB
    BIOPHYSICAL JOURNAL, 1979, 25 (02) : A165 - A165
  • [26] Measurement of flaps blood flow by using non-contact laser Doppler flowmeter
    Jinnouchi, S
    Goto, M
    Katsuki, T
    4TH MEDITERRANEAN CONGRESS OF ORAL AND MAXILLOFACIAL SURGERY, 1997, : 59 - 66
  • [27] Blood flow measurement in reconstructed anterior cruciate ligaments using laser Doppler flowmetry
    Yamagishi T.
    Fujii K.
    Roppongi S.
    Hatsuumi H.
    Knee Surgery, Sports Traumatology, Arthroscopy, 1998, 6 (3) : 160 - 164
  • [28] In vitro validation of volumetric blood flow measurement using Doppler flow wire
    Jenni, R
    Kaufmann, PA
    Jiang, ZH
    Attenhofer, C
    Linka, A
    Mandinov, L
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (08): : 1301 - 1310
  • [29] COMPARATIVE MEASUREMENT OF BLOOD-FLOW WITH ELECTROMAGNETIC AND ULTRASONIC DOPPLER TECHNIQUE
    PASCH, T
    VONDEREM.J
    BAUER, RD
    ZEITSCHRIFT FUR KREISLAUFFORSCHUNG, 1972, 61 (06): : 485 - &
  • [30] The comparison of the variation of peripheral blood flow between anaesthetics using a laser flow meter
    Morita, Tomotaka
    Takemura, Natsuki
    Shibuta, Satoshi
    Uchida, Osamu
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 618 - 618