Detection and Prediction of Bioprosthetic Aortic Valve Degeneration

被引:116
|
作者
Cartlidge, Timothy R. G. [1 ]
Doris, Mhairi K. [1 ]
Sellers, Stephanie L. [2 ]
Pawade, Tania A. [1 ]
White, Audrey C. [1 ]
Pessotto, Renzo [1 ]
Kwiecinski, Jacek [1 ]
Fletcher, Alison [3 ]
Alcaide, Carlos [1 ]
Lucatelli, Christophe [3 ]
Densem, Cameron [4 ]
Rudd, James H. F. [5 ]
van Beek, Edwin J. R. [3 ]
Tavares, Adriana [1 ]
Virmani, Renu [6 ]
Berman, Daniel [7 ]
Leipsic, Jonathon A. [2 ]
Newby, David E. [1 ]
Dweck, Marc R. [1 ]
机构
[1] Univ Edinburgh, British Heart Fdn, Ctr Cardiovasc Sci, Edinburgh, Midlothian, Scotland
[2] Univ Edinburgh, Queens Med Res Inst, Edinburgh Imaging Facil, Edinburgh, Midlothian, Scotland
[3] Univ British Columbia, St Pauls Hosp, Dept Radiol, Vancouver, BC, Canada
[4] Papworth Hosp NHS Fdn Trust, Dept Cardiol, Cambridge, England
[5] Univ Cambridge, Div Cardiovasc Med, Cambridge, England
[6] CVPath Inst, Gaithersburg, MD USA
[7] Cedars Sinai Heart Inst, Los Angeles, CA USA
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
aortic valve replacement; bioprosthetic valve degeneration; calcification; histology; positron emission tomography; SUBCLINICAL LEAFLET THROMBOSIS; PROSTHETIC HEART-VALVES; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; FLUORIDE UPTAKE; TRANSCATHETER; ECHOCARDIOGRAPHY; RECOMMENDATIONS; CALCIFICATION; REPLACEMENT;
D O I
10.1016/j.jacc.2018.12.056
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Bioprosthetic aortic valve degeneration is increasingly common, often unheralded, and can have catastrophic consequences. OBJECTIVES The authors sought to assess whether 18F-fluoride positron emission tomography (PET)-computed tomography (CT) can detect bioprosthetic aortic valve degeneration and predict valve dysfunction. METHODS Explanted degenerate bioprosthetic valves were examined ex vivo. Patients with bioprosthetic aortic valves were recruited into 2 cohorts with and without prosthetic valve dysfunction and underwent in vivo contrast-enhanced CT angiography, 18F-fluoride PET, and serial echocardiography during 2 years of follow-up. RESULTS All ex vivo, degenerate bioprosthetic valves displayed 18F-fluoride PET uptake that colocalized with tissue degeneration on histology. In 71 patients without known bioprosthesis dysfunction, 14 had abnormal leaflet pathology on CT, and 24 demonstrated 18F-fluoride PET uptake (target-to-background ratio 1.55 [interquartile range (IQR): 1.44 to 1.88]). Patients with increased 18F-fluoride uptake exhibited more rapid deterioration in valve function compared with those without (annualized change in peak transvalvular velocity 0.30 [IQR: 0.13 to 0.61] vs. 0.01 [IQR: -0.05 to 0.16] ms(-1)/year; p < 0.001). Indeed 18F-fluoride uptake correlated with deterioration in all the conventional echocardiographic measures of valve function assessed (e. g., change in peak velocity, r <1/4> 0.72; p < 0.001). Each of the 10 patients who developed new overt bioprosthesis dysfunction during follow-up had evidence of 18F-fluoride uptake at baseline (targetto- background ratio 1.89 [IQR: 1.46 to 2.59]). On multivariable analysis, 18F-fluoride uptake was the only independent predictor of future bioprosthetic dysfunction. CONCLUSIONS 18F-fluoride PET-CT identifies subclinical bioprosthetic valve degeneration, providing powerful prediction of subsequent valvular dysfunction and highlighting patients at risk of valve failure. This technique holds major promise in the diagnosis of valvular degeneration and the surveillance of patients with bioprosthetic valves. (18F-Fluoride Assessment of Aortic Bioprosthesis Durability and Outcome [18F-FAABULOUS]; NCT02304276) (J Am Coll Cardiol 2019; 73: 1107-19) (c) 2019 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY license (http://creativecommons. org/licenses/by/4.0/).
引用
收藏
页码:1107 / 1119
页数:13
相关论文
共 50 条
  • [31] Preoperative cholesterol levels do not predict structural valve degeneration in patients undergoing bioprosthetic aortic valve replacement
    Gring, CN
    Houghtaling, P
    Roselli, E
    Novaro, GM
    Banbury, M
    Smedira, N
    Blackstone, EH
    Griffin, BP
    CIRCULATION, 2004, 110 (17) : 709 - 710
  • [32] The place of a stentless aortic bioprosthetic valve
    Correia, Pedro M.
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2018, 37 (10) : 819 - 820
  • [33] Bioprosthetic Aortic Valve Infective Endocarditis
    Rodriguez, Joleen Duarte
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2009, 25 (02) : 116 - 120
  • [34] A notion of bioprosthetic aortic valve durability
    Thyregod, Hans Gustav Horsted
    De Backer, Ole
    Sondergaard, Lars
    EUROPEAN HEART JOURNAL, 2024,
  • [35] Letter by Trimaille et al Regarding Article, "Native Aortic Valve Disease Progression and Bioprosthetic Valve Degeneration in Patients With Transcatheter Aortic Valve Implantation"
    Trimaille, Antonin
    Hmadeh, Sandy
    Morel, Olivier
    CIRCULATION, 2022, 145 (15) : e807 - e808
  • [36] Transcatheter aortic valve in valve implantation with bioprosthetic valve fracture
    James, Taylor M.
    Stamou, Sotiris C.
    Rothenberg, Mark
    Nores, Marcos A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (06) : 1170 - 1172
  • [37] Is bioprosthetic leaflet thrombosis a trigger to valve degeneration?
    Doris, Mhairi Katrina
    Dweck, Marc Richard
    HEART, 2018, 104 (10) : 792 - 793
  • [38] Bioprosthetic aortic valve replacement on a mechanical valve cage
    Ashraf, O.
    Yadav, S.
    EUROPEAN JOURNAL OF HEART FAILURE, 2014, 16 : 34 - 34
  • [39] Noncalcific Mechanisms of Bioprosthetic Structural Valve Degeneration
    Marro, Matteo
    Kossar, Alexander P.
    Xue, Yingfei
    Frasca, Antonio
    Levy, Robert J.
    Ferrari, Giovanni
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2021, 10 (03): : 1 - 13
  • [40] Understanding the driving mechanisms of bioprosthetic valve degeneration
    Wachtell, Kristian
    HEART, 2024, 110 (04) : 223 - 224