A preliminary evaluation of attenuated total reflection Fourier transform infrared spectroscopy for the hematological analysis of thalassemias

被引:11
|
作者
Wan, Jun-Hui [1 ]
Tian, Pei-Ling [2 ]
Yin, Hao [3 ]
Han, Yun [3 ]
Wei, Xiang-Cai [2 ]
Pan, Tao [3 ]
机构
[1] Prenatal Diag Ctr, Guangzhou Women & Childrens Med Ctr, Guangzhou 510623, Guangdong, Peoples R China
[2] Family Planning Res Inst Guangdong, Guangzhou 510515, Guangdong, Peoples R China
[3] Jinan Univ, Guangdong Higher Educ Inst, Key Lab Optoelect Informat & Sensing Technol, Guangzhou 510632, Guangdong, Peoples R China
关键词
ATR-FTIR; Hemoglobin; Mean corpuscular volume; Mean corpuscular hemoglobin; Thalassemia; BETA-THALASSEMIA; IN-SITU; DIAGNOSIS; ALPHA; IDENTIFICATION; TOOL;
D O I
10.1016/j.clinbiochem.2012.10.001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: The effectiveness of attenuated total reflection Fourier transform infrared spectroscopy for the hematological analysis of thalassemias was evaluated. Design and methods: The correlations of hemoglobin, mean corpuscular volume and mean corpuscular hemoglobin between routine method and attenuated total reflection Fourier transform infrared spectroscopy were analyzed using linear regression analysis. Appropriate cut-off values of predicted mean corpuscular volume and predicted mean corpuscular hemoglobin in screening of thalassemias were derived from the receiver operator characteristic curve conducted on 103 subjects. Results: Obvious positive correlations of hemoglobin (beta = 0.876, R-2=0.791, P<0.001), mean corpuscular volume (beta = 0.658, R-2=0.516, P<0.001) and mean corpuscular hemoglobin (beta = 0.674, R-2=0.583, P<0.001) were observed between routine method and attenuated total reflection Fourier transform infrared spectroscopy. Based on the receiver operator characteristic curve analysis, the best cut off value of predicted mean corpuscular volume for the phenotype-positive subjects was found to be 79.9 fl with & sensitivity of 100.0% and-a specificity of 97.8%, and the proposed cut off value of predicted mean corpuscular hemoglobin was 27.3 pg with a sensitivity of 100.0% and a specificity of 96.8%. The area under curve was 0.996 for predicted mean corpuscular volume and 0.992 for predicted mean corpuscular hemoglobin, respectively. Conclusions: The established method could be an additional potentially promising tool for the preliminary screening of thalassemias in population prevention and control program. The main advantage of this method is no unwanted chemical regents compared with conventional method. Strategy for the development of this method could be of use for the other important parameters of thalassemias. (C) 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:128 / 132
页数:5
相关论文
共 50 条
  • [31] Fourier transform infrared attenuated total reflection and transmission spectra studied by dispersion analysis
    MacDonald, SA
    Bureau, B
    APPLIED SPECTROSCOPY, 2003, 57 (03) : 282 - 287
  • [32] Attenuated total reflection Fourier transform infrared spectra of faceted diamonds
    Thongnopkun, Pimthong
    Ekgasit, Sanong
    ANALYTICA CHIMICA ACTA, 2006, 576 (01) : 130 - 135
  • [33] Characterization of Heroin and Its Additives by Attenuated Total Reflection (ATR) - Fourier Transform Infrared Spectroscopy (FTIR) and Multivariate Analysis
    He, Xinlong
    Wang, Jifen
    Niu, Fan
    Fan, Linyuan
    Teng, Xuewei
    Zhang, Chuyue
    He, Xinyu
    ANALYTICAL LETTERS, 2020, 53 (16) : 2656 - 2670
  • [34] Attenuated total reflection: Fourier transform infrared spectroscopy for detection of heterogeneous vancomycin—intermediate Staphylococcus aureus
    Sujintana Wongthong
    Patcharaporn Tippayawat
    Molin Wongwattanakul
    Pirom Poung-ngern
    Lumyai Wonglakorn
    Aroonwadee Chanawong
    Philip Heraud
    Aroonlug Lulitanond
    World Journal of Microbiology and Biotechnology, 2020, 36
  • [35] Discrimination between human and animal blood by attenuated total reflection Fourier transform-infrared spectroscopy
    Ewelina Mistek-Morabito
    Igor K. Lednev
    Communications Chemistry, 3
  • [36] Study of Spectral Modifications in Acidified Ignitable Liquids by Attenuated Total Reflection Fourier Transform Infrared Spectroscopy
    Martin-Alberca, Carlos
    Ernesto Ortega Ojeda, Fernando
    Garcia-Ruiz, Carmen
    APPLIED SPECTROSCOPY, 2016, 70 (03) : 520 - 530
  • [37] Attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy of a single endothelial cell
    Wrobel, Tomasz P.
    Marzec, Katarzyna M.
    Majzner, Katarzyna
    Kochan, Kamila
    Bartus, Magdalena
    Chlopicki, Stefan
    Baranska, Malgorzata
    ANALYST, 2012, 137 (18) : 4135 - 4139
  • [38] Investigation of silicalite-1 crystallization using attenuated total Reflection/Fourier transform infrared Spectroscopy
    Patis, Angelos
    Dracopoulos, Vassilios
    Nikolakis, Vladirniros
    JOURNAL OF PHYSICAL CHEMISTRY C, 2007, 111 (47): : 17478 - 17484
  • [39] Discrimination between human and animal blood by attenuated total reflection Fourier transform-infrared spectroscopy
    Mistek-Morabito, Ewelina
    Lednev, Igor K.
    COMMUNICATIONS CHEMISTRY, 2020, 3 (01)
  • [40] Drowning and postmortem immersion identification using attenuated total reflection-Fourier transform infrared spectroscopy
    Xiong, Hongli
    Wang, Qi
    Zhao, Minzhu
    Zheng, Zhe
    Zhu, Shisheng
    Zhu, Ying
    Li, Yongguo
    Li, Siqiao
    Ding, Shijia
    Li, Hongwei
    Li, Jianbo
    MICROCHEMICAL JOURNAL, 2021, 167