A preliminary evaluation of attenuated total reflection Fourier transform infrared spectroscopy for the hematological analysis of thalassemias

被引:11
|
作者
Wan, Jun-Hui [1 ]
Tian, Pei-Ling [2 ]
Yin, Hao [3 ]
Han, Yun [3 ]
Wei, Xiang-Cai [2 ]
Pan, Tao [3 ]
机构
[1] Prenatal Diag Ctr, Guangzhou Women & Childrens Med Ctr, Guangzhou 510623, Guangdong, Peoples R China
[2] Family Planning Res Inst Guangdong, Guangzhou 510515, Guangdong, Peoples R China
[3] Jinan Univ, Guangdong Higher Educ Inst, Key Lab Optoelect Informat & Sensing Technol, Guangzhou 510632, Guangdong, Peoples R China
关键词
ATR-FTIR; Hemoglobin; Mean corpuscular volume; Mean corpuscular hemoglobin; Thalassemia; BETA-THALASSEMIA; IN-SITU; DIAGNOSIS; ALPHA; IDENTIFICATION; TOOL;
D O I
10.1016/j.clinbiochem.2012.10.001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: The effectiveness of attenuated total reflection Fourier transform infrared spectroscopy for the hematological analysis of thalassemias was evaluated. Design and methods: The correlations of hemoglobin, mean corpuscular volume and mean corpuscular hemoglobin between routine method and attenuated total reflection Fourier transform infrared spectroscopy were analyzed using linear regression analysis. Appropriate cut-off values of predicted mean corpuscular volume and predicted mean corpuscular hemoglobin in screening of thalassemias were derived from the receiver operator characteristic curve conducted on 103 subjects. Results: Obvious positive correlations of hemoglobin (beta = 0.876, R-2=0.791, P<0.001), mean corpuscular volume (beta = 0.658, R-2=0.516, P<0.001) and mean corpuscular hemoglobin (beta = 0.674, R-2=0.583, P<0.001) were observed between routine method and attenuated total reflection Fourier transform infrared spectroscopy. Based on the receiver operator characteristic curve analysis, the best cut off value of predicted mean corpuscular volume for the phenotype-positive subjects was found to be 79.9 fl with & sensitivity of 100.0% and-a specificity of 97.8%, and the proposed cut off value of predicted mean corpuscular hemoglobin was 27.3 pg with a sensitivity of 100.0% and a specificity of 96.8%. The area under curve was 0.996 for predicted mean corpuscular volume and 0.992 for predicted mean corpuscular hemoglobin, respectively. Conclusions: The established method could be an additional potentially promising tool for the preliminary screening of thalassemias in population prevention and control program. The main advantage of this method is no unwanted chemical regents compared with conventional method. Strategy for the development of this method could be of use for the other important parameters of thalassemias. (C) 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:128 / 132
页数:5
相关论文
共 50 条
  • [21] Attenuated total reflection Fourier-transform infrared spectroscopy for the prediction of hormone concentrations in plants
    Holden, Claire A.
    Mcainsh, Martin R.
    Taylor, Jane E.
    Beckett, Paul
    Albacete, Alfonso
    Martinez-Andujar, Cristina
    Morais, Camilo L. M.
    Martin, Francis L.
    ANALYST, 2024, 149 (12) : 3380 - 3395
  • [22] Optical depth profiling by attenuated total reflection Fourier transform infrared spectroscopy: A new approach
    Ekgasit, S
    Ishida, H
    APPLIED SPECTROSCOPY, 1996, 50 (09) : 1187 - 1195
  • [23] Establishment and application of fabrics attenuated total reflection Fourier transform infrared spectroscopy spectrum library
    Wei Z.
    Li W.
    Du Y.
    Ma J.
    Zheng J.
    Fangzhi Xuebao/Journal of Textile Research, 2019, 40 (08): : 64 - 68
  • [24] Attenuated total reflection Fourier transform infrared spectroscopy for on-chip monitoring of solute concentrations
    Greener, Jesse
    Abbasi, Bardia
    Kumacheva, Eugenia
    LAB ON A CHIP, 2010, 10 (12) : 1561 - 1566
  • [25] Characterization of tissue browning products using attenuated total reflection: Fourier transform infrared spectroscopy
    Steele, Alexander
    Walton, Jahmar
    Chakraborty, Sourav
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [26] Characterization of commercial carrageenans by Fourier transform infrared spectroscopy using single-reflection attenuated total reflection
    Volery, P
    Besson, R
    Schaffer-Lequart, C
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (25) : 7457 - 7463
  • [27] Applications of Microstructured Silicon Wafers as Internal Reflection Elements in Attenuated Total Reflection Fourier Transform Infrared Spectroscopy
    Schumacher, Henrik
    Kuenzelmann, Ulrich
    Vasilev, Boris
    Eichhorn, Klaus-Jochen
    Bartha, Johann W.
    APPLIED SPECTROSCOPY, 2010, 64 (09) : 1022 - 1027
  • [28] Comparative Study of Fourier Transform Infrared Spectroscopy in Transmission, Attenuated Total Reflection, and Total Reflection Modes for the Analysis of Plastics in the Cultural Heritage Field
    Picollo, Marcello
    Bartolozzi, Giovanni
    Cucci, Costanza
    Galeotti, Monica
    Marchiafava, Veronica
    Pizzo, Benedetto
    APPLIED SPECTROSCOPY, 2014, 68 (04) : 389 - 397
  • [29] Attenuated Total Reflection-Fourier transform infrared analysis of the fermentation process of pineapple
    Armenta, S
    Garrigues, S
    de la Guardia, M
    Rondeau, P
    ANALYTICA CHIMICA ACTA, 2005, 545 (01) : 99 - 106
  • [30] Drug penetration as studied by noninvasive methods: Fourier transform infrared-attenuated total reflection, Fourier transform infrared, and ultraviolet photoacoustic spectroscopy
    Hanh, BD
    Neubert, RHH
    Wartewig, S
    Christ, A
    Hentzsch, C
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2000, 89 (09) : 1106 - 1113