Characterization of dose-dependent Young's modulus for a radiation-sensitive polymer gel

被引:7
|
作者
Crescenti, Remo A. [1 ]
Bamber, Jeffrey C.
Bush, Nigel L.
Webb, Steve
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 04期
基金
英国工程与自然科学研究理事会;
关键词
RAY COMPUTED-TOMOGRAPHY; TRANSIENT ELASTOGRAPHY; DOSIMETERS; DISTRIBUTIONS; ULTRASOUND; FORCE; ELASTICITY; CALIBRATION;
D O I
10.1088/0031-9155/54/4/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Radiation-sensitive polymer gels for clinical dosimetry have been intensively investigated with magnetic resonance imaging (MRI) because the transversal magnetic relaxation time is dependent on irradiation dose. MRI is expensive and not easily available in most clinics. For this reason, low-cost, quick and easy-to-use potential alternatives such as optical computed tomography (CT), x-ray CT or ultrasound attenuation CT have also been studied by others. Here, we instead evaluate the dose dependence of the elastic material property, Young's modulus and the dose response of the viscous relaxation of radiation-sensitive gels to discuss their potential for dose imaging. Three batches of a radiation-sensitive polymer gel (MAGIC gel) samples were homogeneously irradiated to doses from 0 Gy to 45.5 Gy. Young's modulus was computed from the measured stress on the sample surface and the strain applied to the sample when compressing it axially, and the viscous relaxation was determined from the stress decay under sustained compression. The viscous relaxation was found not to change significantly with dose. However, Young's modulus was dose dependent; it approximately doubled in the gels between 0 Gy and 20 Gy. By fitting a second-order polynomial to the Young's modulus-versus-dose data, 99.4% of the variance in Young's modulus was shown to be associated with the change in dose. The precision of the gel production, irradiation and Young's modulus measurement combined was found to be 4% at 2 Gy and 3% at 20 Gy. Potential sources of measurement error, such as those associated with the boundary conditions in the compression measurement, inhomogeneous polymerization, temperature (up to 1% error) and the evaporation of water from the sample (up to 1% error), were estimated and discussed. It was concluded that Young's modulus could be used for dose determination. Imaging techniques such as elastography may help to achieve this if they can provide a local measurement of Young's modulus, which may eliminate problems associated with the boundaries (e. g. variation in coefficient of friction) and inhomogeneous polymerization. Elastography combined with a calibration should also be capable of mapping dose in three dimensions.
引用
收藏
页码:843 / 857
页数:15
相关论文
共 50 条
  • [1] LATTICE IMAGING OF RADIATION-SENSITIVE POLYMER CRYSTALS
    TSUJI, M
    ROY, SK
    MANLEY, RS
    JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 1985, 23 (06) : 1127 - 1137
  • [2] THE RELEVANCE OF DOSE-FRACTIONATION IN TOMOGRAPHY OF RADIATION-SENSITIVE SPECIMENS
    MCEWEN, BF
    DOWNING, KH
    GLAESER, RM
    ULTRAMICROSCOPY, 1995, 60 (03) : 357 - 373
  • [3] CHARACTERIZATION OF THE RADIATION-SENSITIVE STATE IN THE DEVELOPMENT OF THE COMPOUND EYE OF DROSOPHILA
    FRYXELL, KJ
    KUMAR, JP
    MUTATION RESEARCH, 1993, 285 (02): : 181 - 189
  • [4] DOSE-DEPENDENT RADIATION EFFECT ON MICROVASCULATURE AND REPAIR
    KRISHNAN, EC
    KRISHNAN, L
    JEWELL, B
    BHATIA, P
    JEWELL, WR
    JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1987, 79 (06) : 1321 - 1325
  • [5] RADIATION-INDUCED HYPOPITUITARISM IS DOSE-DEPENDENT
    LITTLEY, MD
    SHALET, SM
    BEARDWELL, CG
    ROBINSON, EL
    SUTTON, ML
    CLINICAL ENDOCRINOLOGY, 1989, 31 (03) : 363 - 373
  • [6] OPTIMUM CONDITIONS FOR ELECTRON-MICROSCOPY OF RADIATION-SENSITIVE POLYMER CRYSTALS
    WHITE, JR
    POLYMER, 1975, 16 (03) : 157 - 160
  • [7] Radiation Dose-Dependent Changes in Lymphatic Remodeling
    Kwon, Sunkuk
    Janssen, Christopher F.
    Velasquez, Fred Christian
    Zhang, Songlin
    Aldrich, Melissa B.
    Shaitelman, Simona F.
    DeSnyder, Sarah M.
    Sevick-Muraca, Eva M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (04): : 852 - 860
  • [8] Development of a porcine skin injury model and characterization of the dose-dependent response to high-dose radiation
    Kim, Jun Won
    Lee, Dong Won
    Choi, Won Hoon
    Jeon, Yeo Reum
    Kim, Se Hoon
    Cho, Haemi
    Lee, Eun-Jung
    Hong, Zhen-Yu
    Lee, Won Jai
    Cho, Jaeho
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (05) : 823 - 831
  • [9] Development of a Porcine Skin Injury Model and Characterization of Dose-dependent Response to High-dose Radiation
    Kim, J.
    Lee, D.
    Choi, W.
    Jeon, Y.
    Cho, H.
    Lee, W.
    Cho, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S681 - S682
  • [10] Dose-resolved serial synchrotron and XFEL structures of radiation-sensitive metalloproteins
    Ebrahim, Ali
    Moreno-Chicano, Tadeo
    Appleby, Martin V.
    Chaplin, Amanda K.
    Beale, John H.
    Sherrell, Darren A.
    Duyvesteyn, Helen M. E.
    Owada, Shigeki
    Tono, Kensuke
    Sugimoto, Hiroshi
    Strange, Richard W.
    Worrall, Jonathan A. R.
    Axford, Danny
    Owen, Robin L.
    Hough, Michael A.
    IUCRJ, 2019, 6 : 543 - 551