Characterization of dose-dependent Young's modulus for a radiation-sensitive polymer gel

被引:7
|
作者
Crescenti, Remo A. [1 ]
Bamber, Jeffrey C.
Bush, Nigel L.
Webb, Steve
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 04期
基金
英国工程与自然科学研究理事会;
关键词
RAY COMPUTED-TOMOGRAPHY; TRANSIENT ELASTOGRAPHY; DOSIMETERS; DISTRIBUTIONS; ULTRASOUND; FORCE; ELASTICITY; CALIBRATION;
D O I
10.1088/0031-9155/54/4/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Radiation-sensitive polymer gels for clinical dosimetry have been intensively investigated with magnetic resonance imaging (MRI) because the transversal magnetic relaxation time is dependent on irradiation dose. MRI is expensive and not easily available in most clinics. For this reason, low-cost, quick and easy-to-use potential alternatives such as optical computed tomography (CT), x-ray CT or ultrasound attenuation CT have also been studied by others. Here, we instead evaluate the dose dependence of the elastic material property, Young's modulus and the dose response of the viscous relaxation of radiation-sensitive gels to discuss their potential for dose imaging. Three batches of a radiation-sensitive polymer gel (MAGIC gel) samples were homogeneously irradiated to doses from 0 Gy to 45.5 Gy. Young's modulus was computed from the measured stress on the sample surface and the strain applied to the sample when compressing it axially, and the viscous relaxation was determined from the stress decay under sustained compression. The viscous relaxation was found not to change significantly with dose. However, Young's modulus was dose dependent; it approximately doubled in the gels between 0 Gy and 20 Gy. By fitting a second-order polynomial to the Young's modulus-versus-dose data, 99.4% of the variance in Young's modulus was shown to be associated with the change in dose. The precision of the gel production, irradiation and Young's modulus measurement combined was found to be 4% at 2 Gy and 3% at 20 Gy. Potential sources of measurement error, such as those associated with the boundary conditions in the compression measurement, inhomogeneous polymerization, temperature (up to 1% error) and the evaporation of water from the sample (up to 1% error), were estimated and discussed. It was concluded that Young's modulus could be used for dose determination. Imaging techniques such as elastography may help to achieve this if they can provide a local measurement of Young's modulus, which may eliminate problems associated with the boundaries (e. g. variation in coefficient of friction) and inhomogeneous polymerization. Elastography combined with a calibration should also be capable of mapping dose in three dimensions.
引用
收藏
页码:843 / 857
页数:15
相关论文
共 50 条
  • [41] Radiation-Sensitive Diselenide Block Co-polymer Micellar Aggregates: Toward the Combination of Radiotherapy and Chemotherapy
    Ma, Ning
    Xu, Huaping
    An, Liping
    Li, Juan
    Sun, Zhiwei
    Zhang, Xi
    LANGMUIR, 2011, 27 (10) : 5874 - 5878
  • [42] CHARACTERIZATION OF ADRIAMYCIN-RESISTANT AND RADIATION-SENSITIVE CHINESE-HAMSTER CELL-LINES
    SOGNIER, MA
    ZHANG, Y
    EBERLE, RL
    BELLI, JA
    BIOCHEMICAL PHARMACOLOGY, 1992, 44 (09) : 1859 - 1868
  • [43] ISOLATION AND SOME PROPERTIES OF RADIATION-SENSITIVE MUTANT OF S TYPHIMURIUM LT-2
    SKAVRONSKAYA, AG
    POKROVSKY, VN
    ZLATEV, VI
    ANDREEVA, IV
    MUTATION RESEARCH, 1969, 7 (02): : 248 - +
  • [44] RADIATION-SENSITIVE PYRIMIDINE AUXOTROPHS OF USTILAGO-MAYDIS .1. ISOLATION AND CHARACTERIZATION OF MUTANTS
    MOORE, PD
    MUTATION RESEARCH, 1975, 28 (03): : 355 - 366
  • [45] Young's modulus of effective clay clusters in polymer nanocomposites
    Xu, Wen
    Zeng, Qinghua
    Yu, Aibing
    POLYMER, 2012, 53 (17) : 3735 - 3740
  • [46] Marijuana's Dose-Dependent Effects in Daily Marijuana Smokers
    Ramesh, Divya
    Haney, Margaret
    Cooper, Ziva D.
    EXPERIMENTAL AND CLINICAL PSYCHOPHARMACOLOGY, 2013, 21 (04) : 287 - 293
  • [47] Thickness Dependence of the Young's Modulus of Polymer Thin Films
    Chang, Jooyoung
    Toga, Kamil B.
    Paulsen, Joseph D.
    Menon, Narayanan
    Russell, Thomas P.
    MACROMOLECULES, 2018, 51 (17) : 6764 - 6770
  • [48] Characterization of the dose-dependent time of peak effect in indirect response models
    Majumdar, A
    JOURNAL OF PHARMACOKINETICS AND BIOPHARMACEUTICS, 1998, 26 (02): : 183 - 206
  • [49] Characterization of Young's Modulus of Nanowires on Microcantilever Beams
    Lilley, Carmen M.
    He, Jin
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 2009, 76 (06): : 1 - 5
  • [50] Characterization of the Young's modulus of CMOS thin films
    Hossain, N
    Ju, JW
    Warneke, B
    Pister, KSJ
    MECHANICAL PROPERTIES OF STRUCTURAL FILMS, 2001, 1413 : 139 - 151