THE RELEVANCE OF DOSE-FRACTIONATION IN TOMOGRAPHY OF RADIATION-SENSITIVE SPECIMENS

被引:116
|
作者
MCEWEN, BF
DOWNING, KH
GLAESER, RM
机构
[1] UNIV CALIF BERKELEY,LAWRENCE BERKELEY LABS,DIV LIFE SCI,BERKELEY,CA 94720
[2] UNIV CALIF BERKELEY,DEPT MOLEC & CELL BIOL,BERKELEY,CA 94720
关键词
D O I
10.1016/0304-3991(95)00082-8
中图分类号
TH742 [显微镜];
学科分类号
摘要
It is commonly assumed that the number of projections required for single-axis tomography precludes its application to most beam-labile specimens. However, Hegerl and Hoppe have pointed out that the total dose required to achieve statistical significance for each voxel of a computed 3D reconstruction is the same as that required to obtain a single 2D image of that isolated voxel, at the same level of statistical significance. Thus a statistically significant 3D image can be computed from statistically insignificant projections, as long as the total dose that is distributed among these projections is high enough that it would have resulted in a statistically significant projection, if applied to only one image. We have tested this critical theorem by simulating the tomographic reconstruction of a realistic 3D model created from an electron micrograph. The simulations verify the basic conclusions of the theorem and extend its validity to the experimentally more realistic conditions of high absorption, signal-dependent noise, varying specimen contrast and missing angular range. Individual projections in the series of fractionated-dose images could be aligned by cross-correlation because they contained significant information derived from the summation of features from different depths in the structure. This latter information is generally not useful for structural interpretation prior to 3D reconstruction, owing to the complexity of most specimens investigated by single-axis tomography. These results demonstrate that it is feasible to use single-axis tomography with soft X-ray and electron microscopy of frozen-hydrated specimens.
引用
收藏
页码:357 / 373
页数:17
相关论文
共 50 条
  • [1] Outstanding issues in radiation dose-fractionation studies
    Hendry, JH
    Mackay, RI
    Roberts, SA
    Slevin, NJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1998, 73 (04) : 383 - 394
  • [2] Radiation dose-fractionation in adult Aedes aegypti mosquitoes
    Yamada, Hanano
    Maiga, Hamidou
    Kraupa, Carina
    Somda, Nanwintoum Severin Bimbile
    Mamai, Wadaka
    Wallner, Thomas
    Bouyer, Jeremy
    [J]. PARASITE, 2023, 30
  • [3] DOSE-FRACTIONATION SENSITIVITY OF PROSTATE CANCER
    Miralbell, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S3 - S3
  • [4] RADIOBIOLOGICAL CONSIDERATIONS OF DOSE-FRACTIONATION AND RADIOSENSITIZATION
    WITHERS, HR
    [J]. LARYNGOSCOPE, 1978, 88 (01): : 37 - 39
  • [5] Radiation dose-fractionation effects in spinal cord: comparison of animal and human data
    Jin, Jian-Yue
    Huang, Yimei
    Brown, Stephen L.
    Movsas, Benjamin
    Kaminski, Joseph
    Chetty, Indrin J.
    Ryu, Samuel
    Kong, Feng-Ming
    [J]. JOURNAL OF RADIATION ONCOLOGY, 2015, 4 (03) : 225 - 233
  • [6] THE EFFECTS OF DOSE-FRACTIONATION ON RADIATION-INDUCED HEART-DISEASE IN RATS
    LAUK, S
    RUTH, S
    TROTT, KR
    [J]. RADIOTHERAPY AND ONCOLOGY, 1987, 8 (04) : 363 - 367
  • [7] THE LIMITATIONS TO RESOLUTION IN THE OBSERVATION OF RADIATION-SENSITIVE SPECIMENS BY ELECTRON-MICROSCOPY
    BOUDET, A
    KUBIN, LP
    [J]. ULTRAMICROSCOPY, 1982, 8 (04) : 409 - 416
  • [8] The Effects of Radiation and Dose-Fractionation on Cancer and Non-Tumor Disease Development
    Liu, William
    Haley, Benjamin M.
    Kwasny, Mary J.
    Li, Jian-Jian
    Grdina, David J.
    Paunesku, Tatjana
    Woloschak, Gayle E.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2012, 9 (12) : 4688 - 4703
  • [9] Dose-Fractionation Schedules for Radiotherapy of Bone Metastases
    Rades, Dirk
    [J]. BREAST CARE, 2010, 5 (05) : 339 - 344
  • [10] DOSE-FRACTIONATION STUDIES ON ADULT FLOUR BEETLES
    DUCOFF, HS
    VAUGHAN, AP
    CROSSLAND, JL
    [J]. RADIATION RESEARCH, 1969, 39 (02) : 472 - +