A quasi-realtime x-ray microtomography system at the Advanced Photon Source

被引:19
|
作者
Wang, YX [1 ]
De Carlo, F [1 ]
Foster, I [1 ]
Insley, J [1 ]
Kesselman, C [1 ]
Lane, P [1 ]
von Laszewski, G [1 ]
Mancini, D [1 ]
McNulty, I [1 ]
Su, MH [1 ]
Tieman, B [1 ]
机构
[1] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
来源
关键词
realtime; x-ray microtomography; supercomputing; Globus; HDF; NeXus;
D O I
10.1117/12.363735
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The combination of high-brilliance x-ray sources, fast detector systems, wide-bandwidth networks, and parallel computers can substantially reduce the time required to acquire, reconstruct, and visualize high-resolution three-dimensional-tomographic data sets. A quasi-realtime computed x-ray microtomography system has been implemented at the 2-BM beamline at the Advanced Photon Source at Argonne National Laboratory. With this system, a complete tomographic data set can be collected in about 15 minutes. Immediately after each projection is obtained, it is rapidly transferred to the Mathematics and Computing Sciences Division where preprocessing and reconstruction calculations are performed concurrently with the data acquisition by a SGI parallel computer. The reconstruction results, once completed, are transferred to a visualization computer that performs the volume rendering calculations. Rendered images of the reconstructed data are available for viewing back at the beamline experiment station minutes after the data acquisition was complete. The fully pipelined data acquisition and reconstruction system also gives us the option to acquire the tomographic data set in several cycles, initially with coarse then with fine angular steps. At present the projections are acquired with a straight-ray projection imaging scheme using 5-20 keV hard x rays in either phase or amplitude contrast mode at a 1-10 mu m resolution. In the future, we expect to increase the resolution of the projections to below 100 nm by using a focused x-ray beam at the 2-ID-B beamline and to reduce the combined acquisition and computation time to the 1 min scale with improvements in the detectors, network links, software pipeline, and computation algorithms.
引用
收藏
页码:318 / 327
页数:10
相关论文
共 50 条
  • [41] X-ray microtomography of materials
    Stock, SR
    INTERNATIONAL MATERIALS REVIEWS, 1999, 44 (04) : 141 - 164
  • [42] X-ray microtomography in biology
    Mizutani, Ryuta
    Suzuki, Yoshio
    MICRON, 2012, 43 (2-3) : 104 - 115
  • [43] X-ray diffraction microtomography
    Grant, J.A., 1600, (06):
  • [44] Realtime imaging in X-ray fluorescence and X-ray diffraction
    Sakurai, Kenji
    Mizusawa, Mari
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2008, 64 : C183 - C184
  • [45] Sequential X-ray Diffraction Topography at 1-BM X-ray Optics Testing Beamline at the Advanced Photon Source
    Stoupin, Stanislav
    Shvyd'ko, Yuri
    Trakhtenberg, Emil
    Liu, Zunping
    Lang, Keenan
    Huang, Xianrong
    Wieczorek, Michael
    Kasman, Elina
    Hammonds, John
    Macrander, Albert
    Assoufid, Lahsen
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [46] X-ray tomography system, automation and remote access at beamline 2-BM of the advanced photon source
    De Carlo, Francesco
    Xiao, Xianghui
    Tieman, Brian
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [47] Process strategies for ultra-deep x-ray lithography at the advanced photon source
    Mancini, DC
    Moldovan, NA
    Divan, R
    De Carlo, F
    Yaeger, J
    MICROMACHINING AND MICROFABRICATION PROCESS TECHNOLOGY VII, 2001, 4557 : 77 - 84
  • [48] X-ray Laue Diffraction Microscopy in 3D at the Advanced Photon Source
    Liu, W.
    Zschack, P.
    Tischler, J.
    Ice, G.
    Larson, B.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 108 - 111
  • [49] X-ray Optics Testing Beamline 1-BM at the Advanced Photon Source
    Macrander, Albert
    Erdmann, Mark
    Kujala, Naresh
    Stoupin, Stanislav
    Marathe, Shashidhara
    Shi, Xianbo
    Wojcik, Michael
    Nocher, Dan
    Conley, Raymond
    Sullivan, Joseph
    Goetze, Kurt
    Maser, Jorg
    Assoufid, Lahsen
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [50] Generation of short x-ray pulses using crab cavities at the advanced photon source
    Harkay, K
    Borland, M
    Chae, YC
    Decker, G
    Dejus, R
    Emery, L
    Guo, W
    Horan, D
    Kim, KJ
    Kustom, R
    Mills, D
    Milton, S
    Nassiri, A
    Pile, G
    Sajaev, V
    Shastri, S
    Waldschmidt, G
    White, M
    Yang, B
    Zholents, A
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 2514 - 2516