A quasi-realtime x-ray microtomography system at the Advanced Photon Source

被引:19
|
作者
Wang, YX [1 ]
De Carlo, F [1 ]
Foster, I [1 ]
Insley, J [1 ]
Kesselman, C [1 ]
Lane, P [1 ]
von Laszewski, G [1 ]
Mancini, D [1 ]
McNulty, I [1 ]
Su, MH [1 ]
Tieman, B [1 ]
机构
[1] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
来源
关键词
realtime; x-ray microtomography; supercomputing; Globus; HDF; NeXus;
D O I
10.1117/12.363735
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The combination of high-brilliance x-ray sources, fast detector systems, wide-bandwidth networks, and parallel computers can substantially reduce the time required to acquire, reconstruct, and visualize high-resolution three-dimensional-tomographic data sets. A quasi-realtime computed x-ray microtomography system has been implemented at the 2-BM beamline at the Advanced Photon Source at Argonne National Laboratory. With this system, a complete tomographic data set can be collected in about 15 minutes. Immediately after each projection is obtained, it is rapidly transferred to the Mathematics and Computing Sciences Division where preprocessing and reconstruction calculations are performed concurrently with the data acquisition by a SGI parallel computer. The reconstruction results, once completed, are transferred to a visualization computer that performs the volume rendering calculations. Rendered images of the reconstructed data are available for viewing back at the beamline experiment station minutes after the data acquisition was complete. The fully pipelined data acquisition and reconstruction system also gives us the option to acquire the tomographic data set in several cycles, initially with coarse then with fine angular steps. At present the projections are acquired with a straight-ray projection imaging scheme using 5-20 keV hard x rays in either phase or amplitude contrast mode at a 1-10 mu m resolution. In the future, we expect to increase the resolution of the projections to below 100 nm by using a focused x-ray beam at the 2-ID-B beamline and to reduce the combined acquisition and computation time to the 1 min scale with improvements in the detectors, network links, software pipeline, and computation algorithms.
引用
收藏
页码:318 / 327
页数:10
相关论文
共 50 条
  • [31] Performance of a high-resolution x-ray microprobe at the advanced photon source
    Cai, Z
    Lai, B
    Yun, W
    McNulty, I
    Khounsary, A
    Maser, J
    Ilinski, P
    Legnini, D
    Trakhtenberg, E
    Xu, S
    Tieman, B
    Wiemerslage, G
    Gluskin, E
    SYNCHROTRON RADIATION INSTRUMENTATION, 2000, 521 : 31 - 34
  • [32] High-resolution x-ray imaging for microbiology at the Advanced Photon Source
    Lai, B
    Kemner, KM
    Maser, J
    Schneegurt, MA
    Cai, Z
    Ilinski, PP
    Kulpa, CF
    Legnini, DG
    Nealson, KH
    Pratt, ST
    Rodrigues, W
    Tischler, ML
    Yun, W
    X-RAY AND INNER-SHELL PROCESSES, 2000, 506 : 585 - 589
  • [33] Beamline and exposure station for deep x-ray lithography at the advanced photon source
    Lai, B
    Mancini, DC
    Yun, W
    Gluskin, E
    MICROLITHOGRAPHY AND METROLOGY IN MICROMACHINING II, 1996, 2880 : 171 - 176
  • [34] Small-angle X-ray scattering instruments at the advanced photon source
    Jemian, Pete R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U3536 - U3536
  • [35] IN-SITU DYNAMICS AT THE ADVANCED PHOTON SOURCE X-RAY IMAGING BEAMLINES
    De Carlo, Francesco
    Xiao, Xianghui
    Fusseis, Florian
    Chawla, Nikhilesh
    CHALLENGES IN MATERIALS SCIENCE AND POSSIBILITIES IN 3D AND 4D CHARACTERIZATION TECHNIQUES, 2010, : 261 - 272
  • [36] High resolution inelastic x-ray scattering spectrometer at the advanced photon source
    Schwoerer-Bohning, M
    Macrander, AT
    Abbamonte, PM
    Arms, DA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (09): : 3109 - 3112
  • [37] Characterization of the X-ray coherence properties of an undulator beamline at the Advanced Photon Source
    Ju, Guangxu
    Highland, Matthew J.
    Thompson, Carol
    Eastman, Jeffrey A.
    Fuoss, Paul H.
    Zhou, Hua
    Dejus, Roger
    Stephenson, G. Brian
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 1036 - 1047
  • [38] X-ray fluorescence microtomography with a Wolter mirror system
    Watanabe, N
    Yamamoto, K
    Takano, H
    Ohigashi, T
    Yokosuka, H
    Aota, T
    Aoki, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 837 - 840
  • [39] Evaluation of a microtomography system with an X-ray microfocus tube
    Lopes, RT
    Rodrigues, JL
    De Assis, JT
    De Jesus, EFO
    De Oliveira, LF
    APPLIED RADIATION AND ISOTOPES, 1997, 48 (10-12) : 1437 - 1442
  • [40] X-RAY MICROTOMOGRAPHY OF BONE
    ELLIOTT, JC
    DOVER, SD
    METABOLIC BONE DISEASE & RELATED RESEARCH, 1984, 5 (01): : 50 - 50