Purpose: To compare two detector systems - one based on the charge-coupled device (CCD) and image amplifier, the other based on a-Si/CsI flat panel, for cone beam computed-tomography (CT) imaging of small animals. A high resolution, high framing rate detector system for the cone beam CT imaging of small animals was developed. The system consists of a 2048x3072x12 bit CCD optically coupled to an image amplifier and an x-ray phosphor screen. The CCD has an intrinsic pixel size of 12 gin but the effective pixel size can be adjusted through the magnification adjustment of the optical coupling systems. The system is used in conjunction with an x-ray source and a rotating stage for holding and rotating the scanned object in the cone beam CT imaging experiments. The advantages of the system include but are not limited to the ability to adjust the effective pixel size and to achieve extremely high spatial resolution and temporal resolution. However, the need to use optical coupling compromises the detective quanta efficiency (DQE) of the system. In this paper, the imaging characteristics of the system were presented and compared with those of an aSi/CsI flat-panel detector system.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Cone BeamMicro-CT System for Small Animal Imaging and Performance Evaluation
    Zhu, Shouping
    Tian, Jie
    Yan, Guorui
    Qin, Chenghu
    Feng, Jinchao
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2009, 2009
  • [42] Gypsum Barrier Shielding Estimates for Two Cone-Beam CT Systems Dedicated to Head Imaging
    Larson, S.
    Goodsitt, M.
    Christodoulou, E.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [43] Flat panel detector-based cone-beam volume CT breast imaging: detector evaluation
    Yu, Y
    Conover, D
    Ning, RL
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 711 - 719
  • [45] Imaging artifacts of Onyx and PHIL on conventional CT, cone-beam CT and MRI in an animal model
    Vollherbst, Dominik F.
    Otto, Ruth
    Do, Thuy
    Kauczor, Hans U.
    Bendszus, Martin
    Sommer, Christof M.
    Moehlenbruch, Markus A.
    INTERVENTIONAL NEURORADIOLOGY, 2018, 24 (06) : 693 - 701
  • [46] Cone Beam CT Imaging for Transbronchial Navigation in Small Peripheral Pulmonary Lesions
    Verhoeven, R.
    Futterer, J.
    Hoefsloot, W.
    Van der Heijden, E.
    JOURNAL OF THORACIC ONCOLOGY, 2019, 14 (10) : S206 - S207
  • [47] Small field of view cone beam CT temporomandibular joint imaging dosimetry
    Lukat, T. D.
    Wong, J. C. M.
    Lam, E. W. N.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (10)
  • [48] Integration of Cone Beam CT Imaging and a Small Animal Conformal RT Device Using a 6DOF Robotic Arm
    Sharma, S.
    Chao, M.
    Moros, E.
    Corry, P.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [49] Using a flat-panel detector in high resolution cone beam CT for dental imaging
    Baba, R
    Ueda, K
    Okabe, M
    DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (05) : 285 - 290
  • [50] Comparison of Online Image Registrations of Varian TrueBeam Cone-Beam CT and BrainLab ExacTrac Imaging Systems
    Li, J.
    Shi, W.
    Andrews, D.
    Werner-Wasik, M.
    Yu, Y.
    Liu, H.
    MEDICAL PHYSICS, 2015, 42 (06) : 3274 - 3274