MRI study of bioabsorbable poly-L-lactic acid devices used for fixation of fracture and osteotomies

被引:14
|
作者
Marumo, K [1 ]
Sato, Y [1 ]
Suzuki, H [1 ]
Kurosaka, D [1 ]
机构
[1] Jikei Univ, Sch Med, Dept Orthopaed Surg, Minato Ku, Tokyo 1058461, Japan
关键词
D O I
10.1007/s00776-005-0989-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. The overall clinical results of bioabsorbable fixation devices made of poly-L-lactic acid (PLLA) used for fixation of fractures, bone grafting, and osteotomies have been favorable. However, clinical studies demonstrated no sign of normal bony architecture restored after surgery, although implant channels had been filled with fibrous tissue. The purpose of the present retrospective study was to examine the extent of structural changes in PLLA devices (PLLA-Ds) for fixation of rotational acetabular osteotomies and displaced malleolar ankle fractures using magnetic resonance imaging (MRI). Methods. Altogether, 14 patients with osteoarthritis of hip joints and 15 with displaced malleolar ankle fractures were operated on using PLLA-D (NEOFIX). Of these patients, 22 were finally enrolled in the study, and the period from operation to the time of the study ranged from 17 to 78 months. The postoperative radiographic findings were evaluated for union, and changes around the implant holes were classified as sclerosis, resorption, or no change. MRI was carried out to estimate changes in the PLLA-Ds. Results. Bone union was obtained in all cases; clinical complications such as infection, joint effusion, soft tissue irritation due to PLLA-D deviation, and motion pain in the joints were not observed. The MRI study suggested that water content in PLLA-D increased mainly due to biodegradation and that implants were not replaced by bony tissue. Conclusions. The PLLA-Ds were degraded but were not replaced by bony tissue during the observation period. Considering these findings and the assumption that in bony tissues mechanical strength of PLLA-D decreases with time, attention should be paid to mechanical insufficiency, which may occur when the cross-sectional area of a PLLA-D extends beyond the cross-sectional area of the osteosynthesis site.
引用
收藏
页码:154 / 158
页数:5
相关论文
共 50 条
  • [41] Fixation of osteochondritis dissecans lesions using poly(l-lactic acid)/poly(glycolic acid) copolymer bioabsorbable screws
    Larsen, MW
    Pietrzak, WS
    DeLee, JC
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (01): : 68 - 76
  • [42] Reduced bone tunnel enlargement post hamstring ACL reconstruction with poly-L-lactic acid/hydroxyapatite bioabsorbable screws
    Robinson, J
    Huber, C
    Jaraj, P
    Colombet, P
    Allard, M
    Meyer, PL
    KNEE, 2006, 13 (02): : 127 - 131
  • [43] Comparison of Acute Recoil between Bioabsorbable Poly-L-lactic Acid XINSORB Stent and Metallic Stent in Porcine Model
    Wu, Yizhe
    Shen, Li
    Wang, Qibing
    Ge, Lei
    Xie, Jian
    Hu, Xi
    Sun, Aijun
    Qian, Juying
    Ge, Junbo
    JOURNAL OF BIOMEDICINE AND BIOTECHNOLOGY, 2012,
  • [44] Intraosseous bioabsorbable poly-L-lactic acid screw presenting as a late foreign-body reaction: A case report
    Mosier-LaClair, S
    Pike, H
    Pomeroy, G
    FOOT & ANKLE INTERNATIONAL, 2001, 22 (03) : 247 - 251
  • [45] Clinical and radiological comparison of bioactive glass and poly-L-lactic acid/hydroxyapatite bioabsorbable interference screws for tibial graft fixation in anterior cruciate ligament reconstruction
    Veizi, Enejd
    Alkan, Hilmi
    Cay, Nurdan
    Sahin, Ali
    Cepni, Sahin
    Tecimel, Osman
    Firat, Ahmet
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (03)
  • [46] Cosmetic Use of Poly-L-Lactic Acid: A Retrospective Study of 130 Patients
    Palm, Melanie D.
    Woodhall, Katrina E.
    Butterwick, Kimberly J.
    Goldman, Mitchel P.
    DERMATOLOGIC SURGERY, 2010, 36 (02) : 161 - 170
  • [47] The role of sonication in preparing injectable poly-l-lactic acid
    Hong, Eun Hye
    Baek, Eun Joo
    Suh, Suk Bae
    Kim, Kwang Ho
    JOURNAL OF COSMETIC DERMATOLOGY, 2022, 21 (05) : 1973 - 1978
  • [48] BIOLOGICAL RESPONSE OF INTRAMEDULLARY BONE TO POLY-L-LACTIC ACID
    SUGANUMA, J
    ALEXANDER, H
    JOURNAL OF APPLIED BIOMATERIALS, 1993, 4 (01) : 13 - 27
  • [49] Evaluation of Cannula Safety in Injection of Poly-L-Lactic Acid
    Nikolis, Andreas
    Avelar, Luiz E.
    Enright, Kaitlyn M.
    CLINICAL COSMETIC AND INVESTIGATIONAL DERMATOLOGY, 2021, 14 : 615 - 622
  • [50] Surface changes of poly-L-lactic acid due to annealing
    Jurik, P.
    Michaljanicova, I.
    Slepicka, P.
    Kolska, Z.
    Svorcik, V.
    4TH INTERNATIONAL SCHOOL AND CONFERENCE ON OPTOELECTRONICS, PHOTONICS, ENGINEERING AND NANOSTRUCTURES (SAINT PETERSBURG OPEN 2017), 2017, 917