MRI study of bioabsorbable poly-L-lactic acid devices used for fixation of fracture and osteotomies

被引:14
|
作者
Marumo, K [1 ]
Sato, Y [1 ]
Suzuki, H [1 ]
Kurosaka, D [1 ]
机构
[1] Jikei Univ, Sch Med, Dept Orthopaed Surg, Minato Ku, Tokyo 1058461, Japan
关键词
D O I
10.1007/s00776-005-0989-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. The overall clinical results of bioabsorbable fixation devices made of poly-L-lactic acid (PLLA) used for fixation of fractures, bone grafting, and osteotomies have been favorable. However, clinical studies demonstrated no sign of normal bony architecture restored after surgery, although implant channels had been filled with fibrous tissue. The purpose of the present retrospective study was to examine the extent of structural changes in PLLA devices (PLLA-Ds) for fixation of rotational acetabular osteotomies and displaced malleolar ankle fractures using magnetic resonance imaging (MRI). Methods. Altogether, 14 patients with osteoarthritis of hip joints and 15 with displaced malleolar ankle fractures were operated on using PLLA-D (NEOFIX). Of these patients, 22 were finally enrolled in the study, and the period from operation to the time of the study ranged from 17 to 78 months. The postoperative radiographic findings were evaluated for union, and changes around the implant holes were classified as sclerosis, resorption, or no change. MRI was carried out to estimate changes in the PLLA-Ds. Results. Bone union was obtained in all cases; clinical complications such as infection, joint effusion, soft tissue irritation due to PLLA-D deviation, and motion pain in the joints were not observed. The MRI study suggested that water content in PLLA-D increased mainly due to biodegradation and that implants were not replaced by bony tissue. Conclusions. The PLLA-Ds were degraded but were not replaced by bony tissue during the observation period. Considering these findings and the assumption that in bony tissues mechanical strength of PLLA-D decreases with time, attention should be paid to mechanical insufficiency, which may occur when the cross-sectional area of a PLLA-D extends beyond the cross-sectional area of the osteosynthesis site.
引用
收藏
页码:154 / 158
页数:5
相关论文
共 50 条
  • [31] Poly-L-lactic acid for facial lipoatrophy in HIV
    El-Beyrouty, Claudine
    Huang, Vanthida
    Darnold, Courtney J.
    Clay, Patrick G.
    ANNALS OF PHARMACOTHERAPY, 2006, 40 (09) : 1602 - 1606
  • [32] Alopecia Induced by Poly-L-Lactic Acid Injection
    Cortez, Gabriel Lazzeri
    Hassun, Karime Marques
    Linhares, Luciana Ribeiro Patricio
    Pinheiro, Maria Valeria Bussamara
    Florenco, Verena
    Michalany, Nilceo Schwery
    Bagatin, Edileia
    de Almeida, Rita Fernanda Cortez
    Melo, Daniel Fernandes
    do Nascimento, Mauricio Mendonca
    CUTIS, 2024, 114 (05): : 159 - 161
  • [33] Poly-L-lactic acid: consultation on the injection techniques
    Vleggaar, D
    JOURNAL OF THE EUROPEAN ACADEMY OF DERMATOLOGY AND VENEREOLOGY, 2006, 20 : 17 - 21
  • [34] Poly-l-Lactic Acid for Neck and Chest Rejuvenation
    Mazzuco, Rosemarie
    Hexsel, Doris
    DERMATOLOGIC SURGERY, 2009, 35 (08) : 1228 - 1237
  • [35] Poly-L-lactic acid - A viewpoint by Graeme Moyle
    Moyle, G
    AMERICAN JOURNAL OF CLINICAL DERMATOLOGY, 2004, 5 (05) : 367 - 367
  • [36] Poly-L-Lactic Acid for Nonfacial Skin Laxity
    Mazzuco, Rosemarie
    Dal'Forno, Taciana
    Hexsel, Doris
    DERMATOLOGIC SURGERY, 2020, 46 : S86 - S88
  • [37] OPTICAL-ACTIVITY OF POLY-L-LACTIC ACID
    ASAHI, T
    FUKASE, H
    ICHIKI, M
    KOBAYASHI, J
    FUKADA, E
    FERROELECTRICS, 1990, 109 : 339 - 342
  • [38] Compositions of injectable poly-d,l-lactic acid and injectable poly-l-lactic acid
    Chen, S. Y.
    Lin, J. Y.
    Lin, C. Y.
    CLINICAL AND EXPERIMENTAL DERMATOLOGY, 2020, 45 (03) : 347 - 348
  • [39] Bioabsorbable Unsintered Hydroxyapatite/Poly-l-Lactic Acid Pin Fixation of Osteochondritis Dissecans in Adolescents: Initial Experiences u-HA/PLLA Pin Fixation in Osteochondritis Dissecans
    Zeilinger, Martin Georg
    Autenrieth, Christian
    Remmel, Kerstin
    Schuh, Alexander
    Hammon, Matthias
    Schraml, Annemarie
    Uder, Michael
    Rompel, Oliver
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2022, 160 (02): : 183 - 189
  • [40] L-Lift Technique Using Poly-l-Lactic Acid: A Pilot Study
    Hexsel, Doris
    Camozzato, Fernanda
    Valente-Bezerra, Indira
    Silva, Aline F.
    Siega, Carolina
    DERMATOLOGIC SURGERY, 2021, 47 (08) : 1087 - 1092